Abstract. Global cities face escalating urban heat stress and energy demands due to rapid vertical growth and densification. Vertical Greenery Systems (VGS), which mitigate urban heat by providing shading and evapotranspiration, offering a promising nature-based solution to enhance environmental sustainability. 3D city models serve as a suitable tool for simulating VGS due to their precise representation of urban environments. However, research leveraging 3D city models in VGS simulations is still limited. To address this challenge, this study evaluates the cooling and energy-saving potential of VGS using 3D city models in Wuhan, Hong Kong, and Singapore. A novel workflow encompassing microclimate simulation, solar irradiation calculation, and view factors computation is developed to assess VGS’s performance over 24 hours on a typical summer day, June 21st. Cooling and energy-saving performance are subsequently estimated. Our study highlights that VGS’s performance strongly correlates with climatic background and urban morphology, offering valuable insights for promoting and optimizing VGS deployment. By pioneering the integration of 3D city models with VGS, this study establishes a foundation for future multi-seasonal and city-scale VGS simulations.
Introduction
As cities grow vertically and become denser, they trap more heat—a phenomenon known as the Urban Heat Island (UHI) effect—leading to skyrocketing energy demands for cooling. Vertical Greenery Systems (VGS), or "green walls," offer a nature-based solution by providing shade and cooling air through evapotranspiration. However, accurately predicting the impact of VGS at a city-wide scale is difficult. Field measurements are too localized to capture cumulative effects, and traditional Computational Fluid Dynamics (CFD) simulations are too computationally expensive for entire urban districts. This research addresses the critical gap in tools that bridge building-scale precision with city-scale planning breadth.
Methodology
The study introduces a novel, scalable workflow that integrates 3D city models with microclimate and energy balance simulations to evaluate VGS potential.
The methodology follows several key steps:
- Facade Discretization: Building facades from 3D models are subdivided into 1-meter grid cells using Ladybug Tools to allow for high-resolution simulation.
- Clustering & Tessellation: To manage computational load, the study area is divided into units using Voronoi tessellation. Buildings with similar morphological traits (height, orientation, canyon width) are clustered into homogeneous units.
- Microclimate Simulation: These units are processed through the Vertical City Weather Generator (VCWG), an urban canopy model simulating vertical variations in temperature and wind.
- Numerical Modeling: An energy balance model accounts for long-wave/short-wave radiation, sensible heat flux, and latent heat flux (evapotranspiration).
- GPU Acceleration: The team utilized Accelerad, a GPU-accelerated lighting simulation tool, to handle the massive ray-tracing required for solar irradiation and view factor calculations.
Datasets
The study utilized several open-source and global datasets to model three cities representing distinct climates: Wuhan (Humid subtropical), Hong Kong (Monsoon-influenced subtropical), and Singapore (Tropical rainforest). Building footprints were sourced from OpenStreetMap and extruded into 3D models, while terrain data was provided by EarthData Digital Elevation Models (DEM). Hourly weather data was obtained from the ERA5 reanalysis dataset.
Results and Discussion
Simulations conducted for a typical summer day (June 21st) revealed that VGS performance is heavily dictated by local climate conditions and urban density.
Climate and Morphology Drivers
- Solar-Driven Cooling: The cooling power of VGS is fueled by the sun. Higher solar radiation intensity enhances evapotranspiration, making VGS more effective in tropical or high-sunlight environments than in cloudy or humid ones.
- Urban Density: High-rise, compact urban layouts benefit the most from VGS. In these areas, the cumulative effect of multiple green facades significantly lowers ambient temperatures. Conversely, low-rise, sparse areas see much lower benefits.
- Nighttime Warming: Simulations found that VGS can cause slight warming at night (up to 0.8°C in Wuhan) by trapping heat and reducing outgoing long-wave radiation or blocking cooling breezes.
Performance Metrics
- Temperature Reduction: Hong Kong saw the highest peak reduction of 2.5°C at 16:00, followed by Singapore at 1.5°C and Wuhan at a modest 0.75°C.
- Energy Savings: For a subset of approximately 2,000 buildings, VGS implementation was projected to save 72.07 GWh in Hong Kong and 81.75 GWh in Singapore.
- Surface Temperatures: Exterior wall surface temperatures saw dramatic drops—up to 28.09°C in Hong Kong—particularly on southwest-facing facades of high-rise buildings.
Conclusion
This study demonstrates that while VGS significantly reduces daytime temperatures and building energy use, its effectiveness is highly sensitive to the climatic background. In humid conditions like those found in Wuhan on the test day, high humidity can actually suppress evapotranspiration and negate cooling benefits. Future research will focus on expanding the temporal scale to multi-seasonal simulations and scaling the model to entire metropolitan areas, while accounting for biological variables like plant species and maintenance.
Summary updated