NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Efficient Polyp Segmentation Via Integrity Learning

Ziqiang Chen, Kang Wang, Yun Liu · DOI

TL;DR

IC-PolypSeg is a new, ultra-efficient neural network designed to solve "integrity deficiency"—the common problem where AI models miss parts of a lesion during colonoscopies. By introducing specific modules to capture both macro-level (finding the whole polyp) and micro-level (finding all its parts) features, the authors achieved state-of-the-art accuracy with a footprint 300 times smaller than previous leading models, reaching real-time speeds of up to 235 FPS.

What Problem Does This Paper Address?

Colorectal cancer is a leading cause of death globally, but early detection via colonoscopy can be life-saving. The challenge is that endoscopists have a "miss rate" of 20% to 47% due to the visual complexity of polyps and the time pressure of the procedure.

While deep learning has improved automated polyp segmentation, existing models often suffer from integrity deficiency. This manifests in two ways:

  1. Macro-level failure: The model fails to identify all distinct polyp regions in an image.
  2. Micro-level failure: The model identifies a polyp but fails to capture its entire area, leaving out edges or internal components.

Furthermore, many high-performing models are computationally heavy, making them difficult to deploy in real-time clinical settings where low latency is critical.

Methods

The authors propose the Integrity Capturing Polyp Segmentation (IC-PolypSeg) network. It uses a lightweight EfficientNet backbone and introduces four specialized components:

  • Receptive Field Expanding (RFE) Module: Inspired by Inception modules, this uses multiple parallel convolutional branches with different kernel sizes to help the network "see" polyps of varying sizes.
  • Pixel-wise Feature Redistribution (PFR): Located at the final encoder stage, this module uses a "query-key" mechanism (similar to attention) to capture global spatial correlations. This ensures that the most "semantic-rich" features are distributed across the entire feature map to preserve integrity.
  • Cross-stage Pixel-wise Feature Redistribution (CPFR): This module dynamically fuses high-level semantic information from deeper layers with low-level spatial details from shallower layers. This helps the model maintain context while refining the shape of the polyp.
  • Coarse-to-fine Calibration (CFC) Module: Functioning as a "plugin" residual block, this module refines the final prediction map by learning the residuals (the differences) between the coarse prediction and the ground truth, specifically targeting precise boundary detection.

Datasets

The researchers evaluated their model on five widely recognized public datasets:

  • Seen (Training/Validation): Kvasir-SEG and CVC-ClinicDB.
  • Unseen (Generalization Testing): ColonDB, ETIS, and EndoScene.

Using "unseen" datasets is a rigorous way to test if the model has actually learned to identify polyps or if it has simply memorized the specific look of the training data.

Key Insights and Ideas

  • Integrity as a Metric: The paper formalizes the "integrity issue" into macro and micro levels. This provides a clearer framework for why models fail in clinical settings—it's not just about being "close" to the shape; it's about not leaving any piece of the lesion behind.
  • Efficiency is a Feature, Not a Compromise: By using EfficientNet backbones (EF0 through EF7), the authors prove that you don't need massive ResNet or Transformer architectures to achieve top-tier results if your feature aggregation modules (like PFR and CPFR) are well-designed.
  • Reducing False Negatives: In a medical context, a False Negative (missing a polyp) is much more dangerous than a False Positive (flagging healthy tissue). IC-PolypSeg specifically focuses on reducing the False Negative Ratio (FNR), which is vital for clinical adoption.

Key Results

  • Speed and Size: The smallest version, IC-PolypSeg-EF0, uses only 0.67M parameters (300x fewer than the popular PraNet) and runs at 235 FPS. This is significantly faster than the standard 30-60 FPS required for real-time video.
  • Accuracy: Despite its size, it outperformed 8 state-of-the-art (SOTA) methods. On the Kvasir-SEG dataset, the EF7 version achieved a mean Dice score of 0.910, surpassing models like SANet and PraNet.
  • Generalization: On the difficult ETIS dataset (unseen during training), the model maintained high performance (0.774 mDice), proving it can handle different imaging conditions and polyp types.
  • Integrity: Qualitative results (visual maps) show that IC-PolypSeg produces much "cleaner" masks with fewer missing parts compared to UNet or MSEG.

Limitations and Future Work

While the paper demonstrates impressive results, a few areas remain for exploration:

  • Video Temporal Consistency: The current model processes frames individually. The authors mention that future work could extend these modules to utilize temporal information in video streams to further improve stability.
  • Broader Modalities: The "integrity learning" concept is currently applied to colonoscopy (RGB images), but the authors suggest it could be adapted for CT, MRI, or histopathology images.
  • Clinical Integration: While the FPS is high, the paper does not discuss the integration into existing endoscopic hardware or how it handles real-world artifacts like smoke, motion blur, or poor lighting.

Summary updated

BibTeX
@misc{chen2023efficient,
  author = {Ziqiang Chen and Kang Wang and Yun Liu},
  title = {{Efficient Polyp Segmentation Via Integrity Learning}},
  year = {2023},
  eprint = {2309.08234},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2309.08234},
}
Figure