Abstract
Non-line-of-sight (NLOS) imaging enables the visualization of objects hidden from direct view by analyzing the time-of-flight of light reflected off a visible relay surface. Despite its potential, current NLOS systems are hindered by slow acquisition rates due to the requirement for dense raster scanning. We present $C^2$NLOS, an efficient framework that utilizes circular confocal scanning patterns. By interpreting the captured data as "transient sinograms," we can perform 1D localization, 2D imaging, and 3D volume reconstruction with up to 60x fewer measurements than traditional methods. Our prototype demonstrates real-time capabilities, achieving acquisition rates of 130 Hz.
Introduction
Non-line-of-sight (NLOS) imaging is a transformative technology that allows sensors to "see around corners" by capturing light that has undergone multiple bounces. Most high-quality NLOS systems employ pulsed lasers and Single-Photon Avalanche Diode (SPAD) sensors to measure the time-of-flight of photons. However, a significant bottleneck remains: the speed of data acquisition. Traditional state-of-the-art methods rely on dense raster scans across a relay wall, which are mechanically slow (typically 2–4 Hz) and computationally demanding. This paper addresses the challenge of achieving high-speed NLOS imaging by optimizing both the scanning pattern and the reconstruction algorithms.
Methodology: $C^2$NLOS
The proposed method, Circular and Confocal NLOS ($C^2$NLOS), replaces the standard grid-based raster scan with a continuous circular scanning path. In this setup, the laser source and the sensor are co-located (confocal) and steered using high-speed galvanometer mirrors.
Transient Sinograms
The core innovation is the mathematical treatment of the circular scan data. The authors demonstrate that a circular scan naturally transforms the 3D position of a hidden scatterer into a sinusoidal pattern in the time-of-flight data. This collection of measurements is termed a "transient sinogram."
Reconstruction Pipeline
The $C^2$NLOS framework supports three levels of reconstruction:
- 1D Reconstruction (Localization): Utilizing a Hough voting procedure, the system identifies sinusoids in the sinogram to instantly calculate the 3D coordinates of hidden points.
- 2D Reconstruction (Imaging): By drawing an analogy to medical computed tomography (CT), the Inverse Radon Transform is applied to the sinogram to recover 2D images of hidden planar objects.
- 3D Reconstruction: For complex scenes, a modified Light Cone Transform (LCT) combined with Alternating Direction Method of Multipliers (ADMM) optimization is used to reconstruct full 3D volumes from sparse data.
Experimental Results
The researchers evaluated $C^2$NLOS using a custom hardware prototype (520nm pulsed laser, SPAD sensor, and galvo mirrors) and the synthetic Z-NLOS dataset.
Key findings include:
- Acquisition Speed: The system operates at 130 Hz, a massive leap from the 2–4 Hz typical of raster-scanning systems.
- Efficiency: High-quality reconstructions are achieved using only 1.6% of the capture time and significantly fewer spatial samples than standard methods.
- Computational Performance: The Inverse Radon Transform approach for 2D imaging provides a 50x speedup in reconstruction time compared to standard LCT methods.
- Image Quality: While the reduced data density introduces some streaking artifacts and noise compared to dense grid scans, the results remain sufficient for object identification and pose estimation.
Conclusion and Future Work
$C^2$NLOS demonstrates that dense spatial sampling is not a prerequisite for effective NLOS imaging. By leveraging the geometric properties of circular scans, the system achieves near real-time performance suitable for tracking moving objects. Future research will focus on mitigating artifacts through advanced "auto-focus" techniques and integrating sinusoidal properties more deeply into 3D reconstruction algorithms to further enhance image fidelity without sacrificing speed.
Summary updated