Dual-stage and Lightweight Patient Chart Summarization for Emergency Physicians

Jiajun Wu, Swaleh Zaidi, Braden Teitge, Henry Leung, Jiayu Zhou, Jessalyn Holodinsky, Steve DrewarXiv 2025 · DOI

Abstract

Emergency physicians frequently face information overload when navigating extensive Electronic Health Records (EHRs) under time-sensitive conditions. While Large Language Models (LLMs) offer powerful summarization capabilities, their deployment in clinical settings is often hindered by privacy regulations regarding Protected Health Information (PHI) and the need for reliable internet connectivity. This paper introduces a dual-stage, lightweight summarization system designed for edge computing. Utilizing Small Language Models (SLMs) on NVIDIA Jetson hardware, the proposed architecture achieves high-quality, context-aware clinical summaries locally. Evaluation on both public and real-world datasets demonstrates that this offline approach maintains high factual accuracy and low latency, providing a viable path for privacy-preserving AI at the point of care.

Introduction

In the Emergency Department (ED), every second counts. Physicians must often synthesize years of unstructured patient notes to make critical decisions. Although cloud-based LLMs like GPT-4 excel at such tasks, they present significant hurdles: the risk of exposing PHI to external servers and the requirement for high-speed connectivity, which may be unavailable in rural or disaster-stricken areas. This research addresses these challenges by developing an "Edge AI" solution—a summarization engine capable of running on low-power, inexpensive hardware situated directly in the clinical environment.

Dual-Stage Architecture

The core innovation is a dual-stage architecture that distributes the computational load across two NVIDIA Jetson Orin Nano devices to overcome memory limitations.

Overview of the dual-stage summarization pipeline featuring Nano-R for retrieval and Nano-S for summarization.
  1. Stage 1: Nano-R (Retrieve): This device processes the raw EHR data. It generates vector embeddings using the BGE-M3 model and employs FAISS (Facebook AI Similarity Search) to identify the top-5 most relevant text segments based on the patient's presenting complaint.
  2. Stage 2: Nano-S (Summarize): The retrieved context is transmitted via a local socket to the second device. This unit hosts a 4-bit quantized SLM which generates two distinct outputs: a list of "Critical Findings" (three key bullet points) and a "Context-Specific Summary" tailored to the current clinical scenario.

By pipelining these tasks, the system avoids memory contention on the 8GB RAM devices, allowing the SLM to remain resident in memory while the retrieval stage prepares subsequent data batches.

Evaluation and Results

The system was tested using the MIMIC-IV-Note dataset and de-identified real-world EHRs from Rockyview General Hospital. Performance was measured using an "LLM-as-Judge" framework to assess Factual Accuracy (FA), focusing on penalizing hallucinations and rewarding evidence-linked claims.

Performance metrics for various SLMs and prompting techniques on real-world EHR data.

Key findings include:

  • Prompting Efficiency: Zero-shot prompting often outperformed more complex techniques like Chain-of-Thought for SLMs. In resource-constrained environments, shorter prompts preserve the limited context window for actual patient data.
  • Latency: The dual-device setup significantly reduced processing time. Summaries were typically generated in under 30 seconds for 2.7B parameter models and approximately 70 seconds for 7B models.
  • Accuracy: The OpenChat model paired with Zero-Shot prompting achieved a high factual accuracy score, proving that smaller models can be highly reliable when supplied with precise, retrieved context.

Conclusion

This work demonstrates that effective clinical AI does not necessitate massive cloud infrastructure. By optimizing SLMs for edge hardware through a dual-stage pipeline, it is possible to provide emergency physicians with rapid, accurate, and private patient summaries. Future work will focus on human-in-the-loop validation with practicing clinicians and further fine-tuning models on specialized medical corpora.

Summary updated

Abstract

Electronic health records (EHRs) contain extensive unstructured clinical data that can overwhelm emergency physicians trying to identify critical information. We present a two-stage summarization system that runs entirely on embedded devices, enabling offline clinical summarization while preserving patient privacy. In our approach, a dual-device architecture first retrieves relevant patient record sections using the Jetson Nano-R (Retrieve), then generates a structured summary on another Jetson Nano-S (Summarize), communicating via a lightweight socket link. The summarization output is two-fold: (1) a fixed-format list of critical findings, and (2) a context-specific narrative focused on the clinician's query. The retrieval stage uses locally stored EHRs, splits long notes into semantically coherent sections, and searches for the most relevant sections per query. The generation stage uses a locally hosted small language model (SLM) to produce the summary from the retrieved text, operating within the constraints of two NVIDIA Jetson devices. We first benchmarked six open-source SLMs under 7B parameters to identify viable models. We incorporated an LLM-as-Judge evaluation mechanism to assess summary quality in terms of factual accuracy, completeness, and clarity. Preliminary results on MIMIC-IV and de-identified real EHRs demonstrate that our fully offline system can effectively produce useful summaries in under 30 seconds.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
Real-world EHRs (Rockyview General Hospital)Zero-Shot (mean across four selected SLMs)Overall FA4.350-shot · models=mean across four selected SLMs · context=chest-pain complaint
Source quote
L372: Averaged across the four models, Zero-Shot attains the highest overall FA at 4.35 and the highest mean Context FA 4.51.
Real-world EHRs (Rockyview General Hospital)CoT (mean across four selected SLMs)Overall FA4.29cot · models=mean across four selected SLMs · context=chest-pain complaint
Source quote
L373: CoT is second overall at 4.29, followed by Self-Ask at 4.16 and Plan-and-Solve at 4.06; Few-Shot is last at 3.79.
Real-world EHRs (Rockyview General Hospital)OpenChat + Zero-ShotOverall FA4.710-shot · context=chest-pain complaint · backbone=OpenChat
Source quote
L379: OpenChat + Zero-Shot achieved the best overall score at 4.71, combining critical and context FA scores.
Real-world EHRs (Rockyview General Hospital)Neural-Chat + CoTOverall FA4.55cot · context=chest-pain complaint · backbone=Neural-Chat
Source quote
L380: Neural-Chat + CoT followed at 4.55 as the top reasoning-oriented setup, yielding the highest Crit Avg at 4.79 with perfect CO and CL score.
Real-world EHRs (Rockyview General Hospital)Mistral + Self-AskOverall FA4.40self-ask · context=chest-pain complaint · backbone=Mistral
Source quote
L381: Mistral + Self-Ask reached 4.40 overall, excelling on the context summary and delivering near-perfect FA at 4.96.
Real-world EHRs (Rockyview General Hospital)Mistral + Self-AskContext-summary FA4.96self-ask · context=chest-pain complaint · backbone=Mistral
Source quote
L381: Mistral + Self-Ask reached 4.40 overall, excelling on the context summary and delivering near-perfect FA at 4.96.
BibTeX
@misc{wu2025dual,
  author = {Jiajun Wu and Swaleh Zaidi and Braden Teitge and Henry Leung and Jiayu Zhou and Jessalyn Holodinsky and Steve Drew},
  title = {{Dual-stage and Lightweight Patient Chart Summarization for Emergency Physicians}},
  year = {2025},
  eprint = {2510.06263},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2510.06263},
}
Figure