Dual-Channel Reliable Breast Ultrasound Image Classification Based on Explainable Attribution and Uncertainty Quantification

Shuge Lei, Haonan Hu, Dasheng Sun, Huabin Zhang, Kehong Yuan, Jian Dai, Jijun Tang, Yan Tong

Introduction

Deep learning models have demonstrated remarkable success in medical imaging, often achieving diagnostic accuracy comparable to or exceeding that of experienced radiologists. In the context of breast ultrasound (BUS) screening, these models offer a powerful tool for early cancer detection. However, a significant barrier to clinical adoption remains: the "black-box" nature of deep neural networks.

In a clinical setting, a correct classification is insufficient if the model's reasoning is flawed or if its confidence is misplaced. A model might correctly identify a malignant lesion by focusing on irrelevant artifacts or background noise rather than the pathological features of the tumor. This lack of transparency leads to a trust gap. To bridge this gap, researchers have developed a framework that evaluates AI not just on its output, but on its reliability—defined through both explainable attribution and uncertainty quantification.

The Dual-Channel Reliability Framework

This research introduces the Dual-Channel Reliability Score (DRS), a comprehensive metric designed to assess the trustworthiness of model predictions. The DRS is calculated by integrating two distinct channels of evaluation:

  1. Inference Reliability Score (IRS): This channel evaluates whether the model is "looking" at the correct anatomical regions. It measures the alignment between the model's focus and clinically relevant areas (the lesion and its immediate periphery).
  2. Predictive Reliability Score (PRS): This channel quantifies the model's internal certainty. It assesses how stable the model's prediction remains when the input image undergoes minor variations.

By combining these two scores, the DRS provides a holistic measure of whether a model is certain and whether that certainty is derived from the right reasons.

SP-RISA: Explainable Attribution via Super-Pixels

To calculate the IRS, the researchers developed a novel attribution method called SP-RISA (Super-pixel based Random Input Sampling for Attribution). Traditional attribution methods, such as the RISE algorithm, often use uniform grids to mask portions of an image to see how the model's output changes. However, medical images contain organic, irregular structures that do not align with square grids. Masking with uniform blocks can introduce noise and obscure the true relationship between features and predictions.

SP-RISA solves this by using "super-pixels"—clusters of pixels grouped by similar intensity and texture that respect the natural boundaries of anatomical structures. By masking these semantically meaningful regions, SP-RISA generates attribution maps that more accurately reflect the model's logic. These maps are then compared against "doctor-trusted" regions. If the model's focus primarily covers the lesion area, it receives a high IRS.

Quantifying Uncertainty

The PRS is derived using Test Time Augmentation (TTA). In this process, a single ultrasound image is subjected to multiple slight modifications, such as rotation, scaling, and flipping, and then passed through the model multiple times. If the model consistently produces the same classification across these variations, it indicates high predictive stability and a high PRS. Conversely, if the model's output fluctuates significantly, the PRS is low, signaling that the model is uncertain about the specific features of that image.

Experimental Evaluation

The framework was validated using two significant datasets:

  • YBUS Dataset: A large-scale clinical dataset from hospitals in China, containing 5,558 images (3,497 malignant, 2,061 benign) annotated by five physicians.
  • BUSI Dataset: A standard public dataset of 780 images used to verify the framework's robustness across different data sources.

The researchers tested the DRS framework across three popular architectures: VGG16, ResNet50, and the Vision Transformer (ViT_b).

Results and Impact

The primary goal of the DRS framework is to improve Expected Calibration Error (ECE)—the gap between a model’s predicted confidence and its actual accuracy. A well-calibrated model is essential for clinical safety; if a model claims 90% confidence, it should be correct 90% of the time.

The results were significant:

  • Calibration Improvement: The DRS framework drastically reduced ECE. For the VGG16 model, reliability measurement improved by 70%, while ResNet50 saw an improvement of over 40%.
  • High Diagnostic Performance: The addition of reliability metrics did not compromise accuracy. The Vision Transformer (ViT_b) achieved a precision of 0.897 and a recall of 0.959 on the YBUS dataset.
  • Clinical Alignment: By moving beyond pure statistics and incorporating "doctor-trusted" rationales, the framework ensures that AI behavior aligns more closely with medical expertise.

Limitations and Future Directions

While the DRS framework represents a major step toward reliable medical AI, some challenges remain. The current criteria for inference reliability are specifically tailored to ultrasound images; adapting this to MRI or CT scans would require redefining what constitutes a trusted rationale for those modalities. Additionally, the use of TTA and SP-RISA increases computational demand. Future research will focus on optimizing these processes—perhaps through methods like Monte Carlo (MC) Dropout—and testing the framework's sensitivity to significant data domain shifts across different ultrasound hardware.

Summary updated

BibTeX
@inproceedings{lei2024dual,
  author = {Shuge Lei and Haonan Hu and Dasheng Sun and Huabin Zhang and Kehong Yuan and Jian Dai and Jijun Tang and Yan Tong},
  title = {{Dual-Channel Reliable Breast Ultrasound Image Classification Based on Explainable Attribution and Uncertainty Quantification}},
  booktitle = {IPMV},
  year = {2024},
  doi = {10.1145/3645259.3645269},
}
Figure