DRDCAE-STGNN: An End-to-End Discrimina-tive Autoencoder with Spatio-Temporal Graph Learning for Motor Imagery Classification

Yi Wang, Haodong Zhang, Hongqi Li

Abstract

Motor imagery (MI) based brain-computer interfaces (BCIs) hold significant potential for assistive technologies and neurorehabilitation. However, the precise and efficient decoding of MI remains challenging due to their non-stationary nature and low signal-to-noise ratio. This paper introduces a novel end-to-end deep learning framework of Discriminative Residual Dense Convolutional Autoencoder with Spatio-Temporal Graph Neural Network (DRDCAE-STGNN) to enhance the MI feature learning and classification. Specifically, the DRDCAE module leverages residual-dense connections to learn discriminative latent representations through joint reconstruction and classifica-tion, while the STGNN module captures dynamic spatial dependencies via a learnable graph adjacency matrix and models temporal dynamics using bidirectional long short-term memory (LSTM). Extensive evaluations on BCI Competition IV 2a, 2b, and PhysioNet datasets demonstrate state-of-the-art performance, with average accuracies of 95.42%, 97.51%, and 90.15%, respectively. Ablation studies confirm the contribution of each component, and interpreta-bility analysis reveals neurophysiologically meaningful connectivity patterns. Moreover, despite its complexity, the model maintains a feasible parameter count and an inference time of 0.32 ms per sample. These results indicate that our method offers a robust, accurate, and interpretable solution for MI-EEG decoding, with strong generalizability across subjects and tasks and meeting the requirements for potential real-time BCI applications.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
BCI IV-2bDRDCAE-STGNNaverage accuracy (Avg Acc)97.51%+4.87 vs baselineMotor Imagery Classification · params=2b · classes=2 · subjects=S1-S9
Source quote
L208: 2025 │ DRDCAE-STGNN │ 98.5 │ 97.5 │ 98.25 │ 95.95 │ 96.43 │ 97.00 │ 98.25 │ 97.50 │ 98.25 │ 97.51 │ 0.90 │ 0.96
PhysioNetDRDCAE-STGNNaverage accuracy95.9%Motor Imagery Classification · classes=2
Source quote
L233: 2025 │ DRDCAE-STGNN │ 95.9 │ 0.958 │ 0.917 │ 0.986 │ 2025 │ DRDCAE-STGNN │ 90.2 │ 0.901 │ 0.936 │ 0.868
PhysioNetDRDCAE-STGNNaverage accuracy90.2%Motor Imagery Classification · classes=4
Source quote
L233: 2025 │ DRDCAE-STGNN │ 95.9 │ 0.958 │ 0.917 │ 0.986 │ 2025 │ DRDCAE-STGNN │ 90.2 │ 0.901 │ 0.936 │ 0.868
Reported baseline / comparator measurements (1)
BenchmarkMethodMetricScoreProtocol / Evidence
BCI IV-2bTrinet baselineaverage accuracy (Avg Acc)92.64%Motor Imagery Classification · params=2b · classes=2 · subjects=S1-S9
Source quote
L206: 2025 │ Trinet \cite{43} │ 93.65 │ 90.43 │ 91.70 │ 95.43 │ 96.09 │ 92.26 │ 90.48 │ 88.67 │ 95.08 │ 92.64** │ 2.57
BibTeX
@misc{wang2025drdcae,
  author = {Yi Wang and Haodong Zhang and Hongqi Li},
  title = {{DRDCAE-STGNN: An End-to-End Discrimina-tive Autoencoder with Spatio-Temporal Graph Learning for Motor Imagery Classification}},
  year = {2025},
  eprint = {2509.05943},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2509.05943},
}