Double-Loop Stability for High Frequency Networked Control Systems Subject to Actuator Saturation
Lists
Only you see this
Abstract
This paper generalizes stability for a high frequency networked control system (NCS) subject to actuator saturation via integral quadratic constraints. A delta operator system with a high frequency constraint is used to model the high frequency NCS. Double-loop stability is treated via outer-loop and interloop feedback configurations for the high frequency NCS. Stability criteria are derived with the high frequency constraint and actuator saturation by a generalized Kalman-Yakubovich-Popov lemma. Numerical results are provided to demonstrate the effectiveness of the proposed techniques in this paper.
BibTeX
@article{yang2019double,
author = {Hongjiu Yang and Peng Li and Yuanqing Xia and Ce Yan},
title = {{Double-Loop Stability for High Frequency Networked Control Systems Subject to Actuator Saturation}},
journal = {IEEE Trans. Cybernetics},
year = {2019},
url = {https://openreview.net/forum?id=CRFQN5wPIHR},
}Loading related content...