Doping Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light

A. Abed Abud, B. Abi, R. Acciarri, M. A. Acero, M. R. Adames, G. Adamov, Mark Adamowski, D. L. Adams, M. Adinolfi, C. Adriano, A. Aduszkiewicz, J. A. Aguilar, B. Aimard, F. Akbar, Kelly C. Allison, S. Alonso Monsalve, Mosab Alrashed, T. Alexander, R. Alvarez, H. Amar Es-sghir, P. Amedo, J. Anderson, D. A. Andrade, C. Andreopoulos, M. Andreotti, M.p. Andrews, F. Andrianala, S. Andringa, Н. Анфимов, Artur M. Ankowski, M Antoniassi, M. Antonova, A. Antoshkin, Alfredo Aranda, L. Arellano, E. Arrieta Díaz, M. A. Arroyave, J. Asaadi, A. Ashkenazi, L. Asquith, E. T. Atkin, D. Auguste, A. Aurisano, V. Aushev, D. Autiero, F. Azfar, H.o. Back, J. J. Back, I. Bagaturia, L. Bagby, N. Balashov, S. Balasubramanian, Pierre Baldi, W. Baldini, B. Baller, Bindu A. Bambah, Rituparna Banerjee, F. Barão, Gabriela Barenboim, Pablo Barham Alzás, Gareth J. Barker, Wayne Barkhouse, G. Barr, J. Barranco Monarca, A. L. F. de Barros, N. Barros, D. Barrow, J. Barrow, A. Basharina-Freshville, A. Bashyal, V. Basque, C. Batchelor, L. Bathe-Peters, James Battat, Francesca De Battisti, F. Bay, M. C. Q. Bazetto, J. L. L. Bazo Alba, J. F. Beacom, E. Bechetoille, B. Behera, E. Belchior, Graydon D. Bell, L. Bellantoni, G. Bellettini, Vincenzo Bellini, O. Beltramello, N. Benekos, C. Benitez Montiel, B. Trocmé, F Bento Neves, J. Berger, S. Berkman, P. Bernardini, A. Bersani, S. Bertolucci, M. Betancourt, A. Betancur Rodríguez, A. J. Bevan · DOI

TL;DR

This paper details the first kiloton-scale test of xenon doping in a liquid argon time projection chamber (LArTPC) at ProtoDUNE-SP. The results demonstrate that adding just 18.8 parts-per-million (ppm) of xenon significantly improves light collection uniformity and successfully recovers scintillation light lost to nitrogen contamination.

What Problem Does This Paper Address?

Liquid Argon Time Projection Chambers (LArTPCs) are the gold standard for next-generation neutrino experiments like DUNE. However, they face a "light problem." Liquid argon (LAr) scintillates in the vacuum ultraviolet (VUV) range at 127 nm. This wavelength is notoriously difficult to detect, requires specialized wavelength shifters, and has a short Rayleigh scattering length, meaning the light bounces around and loses its directional information quickly.

Furthermore, LArTPCs are extremely sensitive to impurities. Even trace amounts of nitrogen (at the ppm level) can "quench" the scintillation process, effectively killing the light signal before it reaches a detector. Finally, because photon detectors are typically mounted only on the anode planes, light collection is highly non-uniform; an event occurring far from the anode is much harder to see than one nearby.

Methods

The researchers used the ProtoDUNE-SP detector at CERN, a massive prototype containing 720 tons of LAr. Over several months in 2020, they performed a controlled doping campaign, injecting xenon in six stages up to a final concentration of 18.8 ppm.

To measure the effects, they utilized:

  • The standard Photon Detection System (PDS): A mix of light guides and ARAPUCA light traps.
  • X-ARAPUCA Prototypes: Two dedicated, high-efficiency detectors. One was sensitive to all light (Ar + Xe), while the other used a fused silica window to filter out the 127 nm argon light, making it sensitive only to the 178 nm xenon light.
  • Cosmic-Ray Tagger (CRT): Used to select specific muon tracks to map the detector's response as a function of distance.
  • Deconvolution Algorithms: Advanced signal processing was used to separate the "fast" (singlet) and "slow" (triplet) components of the scintillation pulse.

Datasets

The study relies on experimental data collected during the 2020 ProtoDUNE-SP run. This includes:

  • Waveforms from the PDS and X-ARAPUCA modules.
  • Reconstructed tracks from the TPC and CRT.
  • Purity monitor data to track electron lifetime.
  • A "baseline" dataset of pure argon (pre-contamination) and a "polluted" dataset (after an accidental nitrogen leak of ~5.4 ppm) to measure the recovery effect.

Key Insights and Ideas

  • The Wavelength Shift: Xenon acts as a molecular "middleman." It intercepts energy from the long-lived argon triplet states and re-emits it at 178 nm. This wavelength is much easier to detect and has a Rayleigh scattering length of ~8.3 meters (compared to ~1 meter for argon), making the LAr volume effectively more transparent.
  • Quenching Competition: Xenon interactions are faster and more efficient than nitrogen quenching. By adding xenon, the researchers "saved" the energy that would have been lost to nitrogen impurities.
  • Uniformity through Scattering: Because 178 nm photons travel much further before scattering, the light collection efficiency becomes significantly more uniform across the 3.6-meter drift distance of the detector.
  • The "Fast" Drop Mystery: One surprising finding was a sudden drop in the "fast" component of the argon light upon the very first injection of xenon. This suggests a direct absorption mechanism that isn't fully explained by standard energy transfer models and warrants further study.

Key Results

  • Light Recovery: Xenon doping recovered approximately 95% of the total light compared to the pure LAr state, effectively neutralizing the impact of the 5.4 ppm nitrogen contamination.
  • Conversion Efficiency: At 18.8 ppm of xenon, the ratio of xenon-produced light to total light was measured at 0.65. When accounting for the transparency of the detector windows, this implies that nearly 81% of the light was shifted to the xenon wavelength.
  • Enhanced Uniformity: The researchers demonstrated a much flatter response curve for light collection versus distance from the anode, which is critical for maintaining energy resolution in massive detectors.
  • TPC Compatibility: After an initial hiccup with low-purity xenon (which introduced fluorinated contaminants), the use of high-purity (5.5 grade) xenon showed no negative impact on the TPC's ability to collect ionization electrons (charge).

Limitations and Future Work

The primary limitation encountered was the accidental introduction of electro-negative impurities ($C_2F_6$, $SF_6$) during the first xenon injection, which temporarily degraded the electron lifetime. This highlights the extreme requirements for dopant purity in LArTPCs.

Future work will involve a combined analysis of this "Single-Phase" data with results from the "Dual-Phase" ProtoDUNE prototype. The collaboration also aims to refine the theoretical models of the ternary Ar-N2-Xe mixture to better understand the unexpected behavior of the fast scintillation component. This test successfully validates xenon doping as a baseline strategy for the second module of the DUNE Far Detector.

Summary updated

Abstract

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.
BibTeX
@article{abud2024doping,
  author = {A. Abed Abud and B. Abi and R. Acciarri and M. A. Acero and M. R. Adames and G. Adamov and Mark Adamowski and D. L. Adams and M. Adinolfi and C. Adriano and A. Aduszkiewicz and J. A. Aguilar and B. Aimard and F. Akbar and Kelly C. Allison and S. Alonso Monsalve and Mosab Alrashed and T. Alexander and R. Alvarez and H. Amar Es-sghir and P. Amedo and J. Anderson and D. A. Andrade and C. Andreopoulos and M. Andreotti and M.P. Andrews and F. Andrianala and S. Andringa and Н. Анфимов and Artur M. Ankowski and M Antoniassi and M. Antonova and A. Antoshkin and Alfredo Aranda and L. Arellano and E. Arrieta Díaz and M. A. Arroyave and J. Asaadi and A. Ashkenazi and L. Asquith and E. T. Atkin and D. Auguste and A. Aurisano and V. Aushev and D. Autiero and F. Azfar and H.O. Back and H.O. Back and J. J. Back and I. Bagaturia and L. Bagby and N. Balashov and S. Balasubramanian and Pierre Baldi and W. Baldini and B. Baller and Bindu A. Bambah and Rituparna Banerjee and F. Barão and Gabriela Barenboim and Pablo Barham Alzás and Gareth J. Barker and Wayne Barkhouse and G. Barr and J. Barranco Monarca and A. L. F. de Barros and N. Barros and D. Barrow and J. Barrow and A. Basharina-Freshville and A. Bashyal and V. Basque and C. Batchelor and L. Bathe-Peters and James Battat and Francesca De Battisti and F. Bay and M. C. Q. Bazetto and J. L. L. Bazo Alba and J. F. Beacom and E. Bechetoille and B. Behera and E. Belchior and Graydon D. Bell and L. Bellantoni and G. Bellettini and Vincenzo Bellini and O. Beltramello and N. Benekos and C. Benitez Montiel and B. Trocmé and F Bento Neves and J. Berger and S. Berkman and P. Bernardini and A. Bersani and S. Bertolucci and M. Betancourt and A. Betancur Rodríguez and A. J. Bevan},
  title = {{Doping Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light}},
  journal = {Journal of Instrumentation},
  year = {2024},
  doi = {10.1088/1748-0221/19/08/p08005},
}
Figure