Does Explicit Prediction Matter in Deep Reinforcement Learning-Based Energy Management?

Zhaoming Qin, Huaying Zhang, Yuzhou Zhao, Hong Xie, Junwei Cao · DOI

Abstract

As a model-free optimization and decision-making method, deep reinforcement learning (DRL) has been widely applied to the field of energy management in the energy Internet. However, some DRL-based energy management schemes also incorporate prediction modules used by traditional model-based methods, which may be unnecessary or even adverse. In this work, we implement a standard energy management scheme with prediction using supervised learning and DRL, and a counterpart without prediction using end-to-end DRL. These two schemes are compared in a unified energy management framework. Simulation results demonstrate that the energy management scheme without prediction is superior to the scheme with prediction, suggesting a need to rectify the potential misuse of DRL methods in this field.

Introduction: The Microgrid Balancing Act

Managing a microgrid involves balancing volatile renewable energy sources (RES), fluctuating consumer demand, and varying electricity prices to minimize costs. A central decision is determining the optimal charging and discharging schedule for Battery Energy Storage (BES) systems.

Figure 1: Microgrid energy management system architecture including renewable energy sources (RES), loads, battery energy storage (BES), and the utility grid.

Traditionally, this was addressed using Model Predictive Control (MPC), which relies on explicit forecasts of future states. As researchers transitioned to model-free DRL, many retained this "prediction-first" structure, training supervised models to forecast the future and feeding those outputs into a DRL agent. This paper investigates whether this explicit prediction step is a benefit or a bottleneck.

Methodology: Modular vs. End-to-End Architectures

The study compares two distinct architectures within a unified framework:

  1. Scheme with Prediction (Modular): A two-stage approach where a Gated Recurrent Unit (GRU) network is trained via supervised learning to predict future power generation, demand, and prices. These predictions are concatenated with the current state and fed into a Proximal Policy Optimization (PPO) agent.
  2. Scheme without Prediction (End-to-End): A pure DRL approach where the PPO agent's actor and critic networks incorporate GRU and MLP layers. The agent processes raw historical data directly, learning to extract temporal features and make decisions simultaneously without explicit prediction targets.
Figure 2: Comparison of energy management schemes: (a) modular architecture with explicit supervised prediction and (b) end-to-end reinforcement learning architecture without explicit prediction.

Both schemes aim to maximize a reward function accounting for grid transaction costs and battery degradation. The models were trained and tested using real-world data from the Pecan Street Database (power) and ENGIE Resources (prices).

Key Insights: Why End-to-End Wins

The authors argue that explicit prediction acts as a form of "lossy" dimensionality reduction. Forcing a network to output a single predicted value discards high-dimensional information in the raw time series that a DRL agent could otherwise exploit.

By contrast, DRL agents are powerful feature extractors. Allowing the agent to process historical sequences directly through its own recurrent layers enables it to automatically learn parameters optimized specifically for the control task, rather than for prediction accuracy.

Results and Performance

Simulation results favored the end-to-end approach across several metrics:

  • Superior Rewards: The scheme without prediction achieved a higher mean episode reward.
  • Faster Convergence: The end-to-end agent reached high performance levels significantly faster than the modular agent, which required approximately $2 \times 10^5$ episodes to match its performance.
  • Effective Strategy: Qualitative analysis showed the end-to-end agent successfully learned "buy low, sell high" behaviors, optimizing battery usage during peak and off-peak hours without explicit forecasts.

While 1-step predictions were more accurate than 2-step predictions in the modular scheme, neither outperformed the direct data-to-action mapping of the end-to-end DRL agent.

Conclusion

This work serves as a methodological correction for the energy management field. It demonstrates that the intuition borrowed from model-based control—that one must predict the future to plan for it—does not necessarily hold for the representational power of deep reinforcement learning. Future work will explore how these findings scale to multi-agent systems and more complex, volatile environments.

Summary updated

Abstract

As a model-free optimization and decision-making method, deep reinforcement learning (DRL) has been widely applied to the filed of energy management in energy Internet. While, some DRL-based energy management schemes also incorporate the prediction module used by the traditional model-based methods, which seems to be unnecessary and even adverse. In this work, we implement the standard energy management scheme with prediction using supervised learning and DRL, and the counterpart without prediction using end-to-end DRL. Then, these two schemes are compared in the unified energy management framework. The simulation results demonstrate that the energy management scheme without prediction is superior over the scheme with prediction. This work intends to rectify the misuse of DRL methods in the field of energy management.
BibTeX
@misc{qin2021does,
  author = {Zhaoming Qin and Huaying Zhang and Yuzhou Zhao and Hong Xie and Junwei Cao},
  title = {{Does Explicit Prediction Matter in Deep Reinforcement Learning-Based Energy Management?}},
  year = {2021},
  eprint = {2108.05099},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2108.05099},
}
Figure