Introduction
In clinical MRI, raw data is acquired in the frequency domain, known as "k-space." To accelerate acquisition, clinicians often undersample this data. The conventional workflow for cardiac analysis involves a two-step process: first, reconstructing an image from the undersampled k-space via an Inverse Fast Fourier Transform (IFFT) or deep learning reconstruction, and second, segmenting the resulting image.
This traditional pipeline suffers from two primary drawbacks. First, at high acceleration factors, reconstruction artifacts such as aliasing and blurring propagate into the segmentation stage, degrading performance. Second, reconstruction models are typically optimized for pixel-level visual quality, which may not align with the structural requirements of segmentation tasks.
The DiSK Framework
To address these issues, we present DiSK (Direct Segmentation from K-space). DiSK is a Transformer-based architecture designed to predict cardiac segmentations directly from raw, undersampled k-space data, bypassing the intermediate reconstruction step entirely.
The core of DiSK is a Perceiver-based encoder. Standard Transformers face $O(N^2)$ complexity, making them unsuitable for the high dimensionality of k-space data. The Perceiver architecture overcomes this by using cross-attention to map input points into a small, fixed-size latent bottleneck. This allows the model to capture global correlations across the entire frequency domain efficiently. The decoder then queries these latent features using image-space coordinates $(x, y, t)$ to generate class probabilities for each pixel.
Experimental Results
The model was trained and validated using 1,200 mid-ventricular slices from the UK Biobank (UKB). K-space data was synthesized from magnitude images, incorporating simulated phase inconsistencies. We tested the model against Cartesian undersampling masks at acceleration factors ranging from 4× to 64×.
DiSK demonstrated exceptional robustness to data sparsity. While image-based baselines (Syn-Net and LI-Net) showed significant performance drops as acceleration increased, DiSK maintained a consistent Dice score of approximately 0.902 across all factors.
Visually, DiSK produces clean and anatomically accurate segmentation masks even at 64× acceleration. At this level of undersampling, the zero-filled reconstructions are virtually unrecognizable to human observers, yet DiSK successfully identifies the left ventricle and myocardium. Quantitatively, DiSK also reduced the Hausdorff distance by approximately 2 pixels compared to the baselines, indicating superior boundary precision.
Discussion and Conclusion
The success of DiSK suggests that high-level anatomical information can be extracted from extremely sparse frequency samples that lack sufficient information for high-quality image reconstruction. By leveraging the global receptive field of Transformers, DiSK avoids the artifact propagation inherent in traditional pipelines.
Future research will focus on applying DiSK to real-world multi-coil k-space data and scaling the architecture to handle full 3D cardiac volumes. Additionally, we aim to evaluate the model's performance on downstream clinical tasks, such as calculating Ejection Fraction (EF) directly from k-space.
Summary updated