Determining HEDP Foams' Quality with Multi-View Deep Learning Classification

Nadav Schneider, Matan Rusanovsky, Raz Gvishi, Gal Oren · DOI

Abstract

In High Energy Density Physics (HEDP) research, the quality of low-density silica aerogels is paramount to experimental accuracy. Traditionally, these "frozen smoke" materials are inspected manually—a subjective and time-consuming process. This paper details a multi-view deep learning approach designed to automate aerogel quality control. By integrating surface scans and cross-sectional profiles through a view-pooling architecture, the model achieves an accuracy of 86%, matching expert intuition. Furthermore, the implementation of Local Interpretable Model-agnostic Explanations (LIME) ensures the model's decisions are grounded in physical defects, providing the transparency required for scientific applications.

1. Introduction

High Energy Density Physics (HEDP) experiments often involve the study of dynamic wave-fronts as they propagate through low-density materials. Silica aerogels, known for their extreme porosity (often exceeding 90% air) and fragility, are the standard medium for these studies. However, the physical integrity of these foams—specifically their density and homogeneity—is critical. Even minor surface scratches or internal irregularities can significantly alter experimental outcomes.

Currently, quality assurance is a manual bottleneck. A physicist must evaluate five distinct images for every foam sample: two surface views (top and bottom) and three side-profile cross-sections. This process is not only labor-intensive but also subjective, particularly when dealing with "normal-defective" cases—samples that exhibit minor imperfections but may still be functional. To address this, we propose an automated, explainable deep learning pipeline capable of mimicking the "physicist’s eye."

2. Methodology

The core of the proposed solution is a Multi-View Deep Learning architecture. Unlike traditional image classifiers that analyze images in isolation, this model processes all five views of a foam sample simultaneously to arrive at a single classification.

2.1 Model Architecture

The system utilizes a modified ResNet Convolutional Neural Network (CNN) backbone. To adapt the architecture to a relatively small dataset and prevent overfitting, the model was "pruned" by removing the final 18 convolutional layers. Feature maps from each of the five views are then aggregated using a "view pooling" layer. This approach allows the network to synthesize information from 2D surface scans and 3D profile views regardless of their specific spatial orientation.

2.2 Physics-Guided Pre-processing

To improve signal-to-noise ratios, the team implemented custom pre-processing steps:

  • Circle Extraction: An automated masking algorithm isolates the circular foam surface from the background.
  • Intensity Quantization: Pixel values are binned into ten discrete levels. This reduces background noise and minimizes the impact of variance in the non-informative "black" areas of the scans.

2.3 Explainable AI (LIME)

Transparency is vital in scientific workflows. The researchers employed Local Interpretable Model-agnostic Explanations (LIME) to visualize the model's decision-making process. By highlighting the specific pixels that contribute to a "defective" classification, LIME confirms that the model focuses on physical flaws—such as stains or scratches—rather than imaging artifacts.

3. Experimental Design and Dataset

The study utilized a specialized "few-shot" dataset consisting of 95 labeled foam samples (475 total images). Samples were categorized into three classes: Normal, Defective, and Normal-Defective. Following a conservative physics principle—"if there is a doubt, there is no doubt"—the "normal-defective" samples were grouped with the "defective" class for training purposes.

To compensate for the limited sample size, aggressive data augmentation was employed. This included rotations of up to 270° for circular surface views, the addition of Gaussian noise, and contrast adjustments to simulate varying lighting conditions.

4. Results and Discussion

The multi-view model demonstrated robust performance across several configurations. The highest accuracy (86%) was achieved using only the top and bottom surface views, suggesting that surface-level defects are often the most reliable indicators of overall quality. However, the "Full Group" model (utilizing all five images) achieved the best Area Under the Curve (AUC) at 84%, indicating superior generalization and a better balance between precision and recall.

A key finding was the impact of data quality over quantity. The inclusion of "normal-defective" samples improved the model's ability to distinguish subtle nuances. Furthermore, the addition of just 20 training examples resulted in an 8% increase in average accuracy, highlighting the high value of expert-labeled data in low-data regimes.

5. Conclusion and Future Work

This research provides a successful proof-of-concept for the automated inspection of HEDP aerogels. The multi-view deep learning approach matches human intuition while offering an objective, repeatable, and explainable metric for quality control.

Future research will focus on expanding the dataset to move beyond few-shot learning. Additionally, the authors plan to explore alternative architectures, such as Inception-based models, and test feature map concatenation as an alternative to view pooling to determine if preserving the spatial order of profile scans further enhances classification accuracy.

Summary updated