Abstract
Detecting change-points in time series is critical for applications ranging from medical diagnostics to industrial monitoring. However, real-world data often contains nuisance variables like sensor calibration drift that can trigger false positives. This paper presents a non-parametric method that compares distributions of ordinal patterns using Maximum Mean Discrepancy (MMD). By focusing on the relative order of values rather than raw magnitudes, the approach is invariant to non-linear monotonic transformations. We introduce a Corrected MMD (CMMD) to improve localization accuracy and an $O(N^2)$ algorithm for computational efficiency. Evaluations on simulated and real-world EEG/ECG data demonstrate the method's robustness and sensitivity.
Introduction
In fields like medical diagnostics (EEG/ECG) or industrial quality control, identifying exactly when a system's behavior changes is paramount. However, real-world sensors often suffer from "calibration drift"—where the baseline or scale of the measurement shifts due to physical factors rather than a change in the actual signal. Existing change-point detection methods often struggle with sensitivity to these nuisance variables and high computational complexity, often scaling cubically ($O(N^3)$) with the number of data points.
This paper introduces a fast, non-parametric method for detecting change-points by comparing the distributions of "ordinal patterns" using Maximum Mean Discrepancy (MMD). This approach is uniquely robust to non-linear monotonic transformations, allowing it to ignore sensor calibration shifts while accurately pinpointing changes in underlying system dynamics.
Methods
The proposed method combines ordinal pattern analysis with kernel-based distribution comparison.
Ordinal Pattern Distributions
Instead of raw values, the method analyzes the relative order of successive values in small windows of size $d+1$. For a given window, there are $(d+1)!$ possible permutations or "patterns." Because this representation only considers "greater than" or "less than" relationships, the resulting distribution is invariant to any strictly increasing transformation of the data.
Maximum Mean Discrepancy and Bias Correction
Maximum Mean Discrepancy (MMD) is used to determine if two sets of samples come from the same distribution. The time series is treated as a sequence of empirical ordinal distributions. To address the observation that standard MMD is biased toward picking change-points at the sequence edges, the authors introduce Corrected MMD (CMMD), which penalizes these edge cases to improve localization accuracy.
Efficient Computation
By deriving an iterative update formula, the computational cost of searching for a change-point is reduced from $O(N^3)$ to $O(N^2)$, enabling the processing of high-resolution, long-duration time series.
Results and Discussion
The method was evaluated using simulated AR(1) processes with non-linear distortions, as well as real-world EEG and ECG data.
In simulations, the CMMD estimator correctly identified change-points despite heavy non-linear distortion, whereas standard MMD showed significant bias. On real EEG data (64,000 points), the method successfully localized the onset of an epileptic seizure at the 160-second mark. In high-resolution ECG recordings, it detected subtle heart rate increases (from 90 to 105 bpm) within a 10-second window.
Conclusion
The use of ordinal patterns provides inherent robustness to common sensor noise by focusing on the statistics of local dynamics rather than raw magnitudes. While the method offers significant scalability and invariance, it involves a trade-off between window size (for estimation accuracy) and localization precision. Future work may involve developing formal statistical significance tests to complement the current estimation framework.
Summary updated