Deep Learning Based Signal Enhancement of Low-Resolution Accelerometer for Fall Detection Systems

Kai-Chun Liu, Kuo-Hsuan Hung, Chia-Yeh Hsieh, Hsiang-Yun Huang, Chia-Tai Chan, Yu Tsao

Abstract

In the last two decades, fall detection (FD) systems have been developed as a popular assistive technology. Such systems automatically detect critical fall events and immediately alert medical professionals or caregivers. To support long-term FD services, various power-saving strategies have been implemented. Among them, a reduced sampling rate is a common approach for an energy-efficient system in the real-world. However, the performance of FD systems is diminished owing to low-resolution (LR) accelerometer signals. To improve the detection accuracy with LR accelerometer signals, several technical challenges must be considered, including misalignment, mismatch of effective features, and the degradation effects. In this work, a deep-learning-based accelerometer signal enhancement (ASE) model is proposed to improve the detection performance of LR-FD systems. This proposed model reconstructs high-resolution (HR) signals from the LR signals by learning the relationship between the LR and HR signals. The results show that the FD system using support vector machine and the proposed ASE model at an extremely low sampling rate (sampling rate < 2 Hz) achieved 97.34% and 90.52% accuracies in the SisFall and FallAllD datasets, respectively, while those without ASE models only achieved 95.92% and 87.47% accuracies in the SisFall and FallAllD datasets, respectively. This study demonstrates that the ASE model helps the FD systems tackle the technical challenges of LR signals and achieve better detection performance.

Introduction

Wearable fall detection (FD) systems are critical for elderly care, but they face a fundamental engineering trade-off: battery life vs. detection accuracy. To provide long-term service, these devices often use low sampling rates (e.g., <10 Hz) to save power, as data sampling and transmission account for up to 90% of a wearable's energy consumption. However, low-resolution (LR) signals lose "fine-grained" information—the sharp impacts and specific vibrations that characterize a fall. This leads to a "feature mismatch" where classifiers trained on high-quality data fail when deployed on low-power hardware. This paper introduces a deep learning-based Accelerometer Signal Enhancement (ASE) model that reconstructs high-resolution motion data from extremely low-sampling-rate wearable sensors.

Methodology

The core innovation is the ASE model, designed as a front-end "enhancer" that sits between the raw sensor data and the final classifier.

Deep Denoising Convolutional Autoencoder

The model uses an encoder-decoder architecture to "hallucinate" high-resolution (HR) details back into low-power signal streams. The encoder uses convolutional layers to capture temporal movement patterns and dense layers to map these to a high-resolution latent space. The decoder then reconstructs the 3-axis accelerometer signal into a high-resolution format.

Overview of the ASE model architecture and signal reconstruction

Impact-Defined Windowing

Instead of simple sliding windows, the system identifies the "impact point" (the peak magnitude) and captures a specific window around it (e.g., 2s before and ~1.4s after) to ensure the most critical data is processed. This ensures that the reconstruction focuses on the most informative part of the signal.

Impact-defined windowing strategy used to capture critical fall data

Experimental Results

The model was validated using two public datasets: SisFall and FallAllD, which were artificially downsampled to various rates ranging from ~119 Hz down to ~1.5 Hz.

Performance at Extreme Low Power

The most significant finding is that the model can effectively distinguish falls even at sampling rates below 2 Hz. At this frequency, a raw signal looks like a jagged, unrecognizable line, but the ASE model recovers enough structural "impact" information for a classifier to make an accurate decision. At a sampling rate of < 2 Hz, the ASE + SVM combo achieved:

  • 97.34% accuracy on SisFall (vs. 95.92% without enhancement).
  • 90.52% accuracy on FallAllD (vs. 87.47% without enhancement).

Efficiency and Deployment

The authors simulated the model on an STM32 microcontroller. At a 25 Hz sampling rate, the system could operate for roughly 6.9 hours on a small battery with a response time of 9.8 seconds, proving the feasibility of real-time deployment.

Conclusion

The ASE model helps FD systems tackle the technical challenges of LR signals and achieve better detection performance. While the model shows promise, future work includes validation on real-world datasets from elderly individuals and further optimizing the model for ultra-low-power wearables.

Summary updated

Abstract

In the last two decades, fall detection (FD) systems have been developed as a popular assistive technology. Such systems automatically detect critical fall events and immediately alert medical professionals or caregivers. To support long-term FD services, various power-saving strategies have been implemented. Among them, a reduced sampling rate is a common approach for an energy-efficient system in the real-world. However, the performance of FD systems is diminished owing to low-resolution (LR) accelerometer signals. To improve the detection accuracy with LR accelerometer signals, several technical challenges must be considered, including misalignment, mismatch of effective features, and the degradation effects. In this work, a deep-learning-based accelerometer signal enhancement (ASE) model is proposed to improve the detection performance of LR-FD systems. This proposed model reconstructs high-resolution (HR) signals from the LR signals by learning the relationship between the LR and HR signals. The results show that the FD system using support vector machine and the proposed ASE model at an extremely low sampling rate (sampling rate < 2 Hz) achieved 97.34% and 90.52% accuracies in the SisFall and FallAllD datasets, respectively, while those without ASE models only achieved 95.92% and 87.47% accuracies in the SisFall and FallAllD datasets, respectively. This study demonstrates that the ASE model helps the FD systems tackle the technical challenges of LR signals and achieve better detection performance.
BibTeX
@article{liu2022deep,
  author = {Kai-Chun Liu and Kuo-Hsuan Hung and Chia-Yeh Hsieh and Hsiang-Yun Huang and Chia-Tai Chan and Yu Tsao},
  title = {{Deep Learning Based Signal Enhancement of Low-Resolution Accelerometer for Fall Detection Systems}},
  journal = {IEEE Trans. Cogn. Dev. Syst},
  year = {2022},
  doi = {10.1109/tcds.2021.3116228},
}
Figure