Abstract
Radiology Report Generation (RRG) automates the creation of radiology reports from medical imaging, enhancing the efficiency of the reporting process. Longitudinal Radiology Report Generation (LRRG) extends RRG by incorporating the ability to compare current and prior exams, facilitating the tracking of temporal changes in clinical findings. Existing LRRG approaches only extract features from prior and current images using a visual pre-trained encoder, which are then concatenated to generate the final report. However, these methods struggle to effectively capture both spatial and temporal correlations during the feature extraction process. Consequently, the extracted features inadequately capture the information of difference across exams and thus underrepresent the expected progressions, leading to sub-optimal performance in LRRG. To address this, we develop a novel dynamic difference-aware temporal residual network (DDaTR). In DDaTR, we introduce two modules at each stage of the visual encoder to capture multi-level spatial correlations. The Dynamic Feature Alignment Module (DFAM) is designed to align prior features across modalities for the integrity of prior clinical information. Prompted by the enriched prior features, the dynamic difference-aware module (DDAM) captures favorable difference information by identifying relationships across exams. Furthermore, our DDaTR employs the dynamic residual network to unidirectionally transmit longitudinal information, effectively modelling temporal correlations. Extensive experiments demonstrated superior performance over existing methods on three benchmarks, proving its efficacy in both RRG and LRRG tasks.
Introduction
Generating radiology reports that accurately track a patient's disease progression over time is a major challenge in medical AI. While standard Radiology Report Generation (RRG) focuses on single-time-point descriptions, Longitudinal RRG (LRRG) requires models to compare current exams with historical data to identify progressions, improvements, or stable conditions.
Existing LRRG models often process past and present images independently, performing "late fusion" by concatenating features only at the final stage. This approach fails to capture fine-grained spatial and temporal correlations visible in earlier network layers and typically ignores the rich clinical context provided by the prior report. To overcome these limitations, we introduce DDaTR, a novel architecture that dynamically fuses prior images, prior reports, and current images at multiple levels of the visual encoder.
The DDaTR Framework
The core innovation of DDaTR is the integration of longitudinal information at every stage of the visual encoder through two plug-and-play modules. This multi-level fusion allows the model to detect subtle texture and structural changes that late-fusion methods miss.
Dynamic Feature Alignment Module (DFAM)
DFAM aligns the prior image with the prior report (encoded via a frozen BERT model) using cross-attention. By injecting clinical semantics from the previous report into the prior image's features, the module directs the visual encoder to focus on clinically relevant regions identified in past diagnoses.
Dynamic Difference-aware Module (DDAM)
Using the text-enhanced prior features and current image features, DDAM highlights texture details and computes explicit pixel-wise differences between exams. This allows the model to explicitly represent temporal changes.
Unidirectional Residual Flow
Difference-aware features are transmitted unidirectionally from past to present via a dynamic residual network. This gated flow ensures that the current image representation is enriched by longitudinal context without being overwhelmed by historical data.
Experimental Evaluation
We evaluated DDaTR on three key benchmarks: MIMIC-CXR, Longitudinal-MIMIC, and IU-Xray.
Key Results and Insights
- State-of-the-Art Clinical Accuracy: DDaTR achieved SOTA performance on Clinical Efficacy (CE) metrics, which measure the accuracy of disease labels and attributes. On MIMIC-CXR, it reached an F1_macro CE score of 0.441, a significant improvement over the PromptMRG baseline (+0.048).
- Text-Guided Vision: The use of prior reports as a semantic anchor via DFAM proved essential for focusing the visual encoder on relevant abnormalities rather than background noise.
- Specialized Efficiency: Despite having only 247M parameters, DDaTR outperformed massive generalist medical LLMs like LLaVA-Med and Med-Flamingo on the LRRG task. It ranked 2nd overall on the official ReXrank leaderboard, surpassing several multi-billion parameter models.
Conclusion
DDaTR demonstrates that early, multi-level fusion of multi-modal longitudinal data significantly improves the clinical accuracy of automated radiology reports. By explicitly modeling differences and using prior text to guide visual feature extraction, the model effectively captures disease progression. Future work will explore extending this framework to 3D imaging modalities like CT and MRI and addressing remaining challenges such as model hallucinations.
Summary updated