Abstract
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Any neutrinoless double-beta decay search requires a thorough understanding of the background and the signal energy spectra. The various techniques employed to ensure the integrity of the measured spectra are discussed. Data collection is monitored with a thorough set of checks, and subsequent careful analysis is performed to qualify the data for higher level physics analysis. Instrumental background events are tagged for removal, and problematic channels are removed from consideration as necessary.
Introduction: The Challenge of Rare-Event Detection
The MAJORANA DEMONSTRATOR experiment is on a quest for one of the rarest events in physics: neutrinoless double-beta decay ($0\nu\beta\beta$) in Germanium-76 ($^{76}$Ge). Observation of this decay would confirm that neutrinos are Majorana fermions—particles that are their own antiparticles—and provide a key to understanding the matter-antimatter asymmetry in our universe.
However, the signal for $0\nu\beta\beta$ is a minute energy peak at 2039 keV, occurring with extreme rarity. In such a sensitive search, "background" is the primary obstacle. Instrumental noise, such as random bit flips in electronics or microphonic vibrations from cryogenic maintenance, can easily mimic or obscure the signal. To prevent these artifacts from being mistaken for a discovery, the MAJORANA collaboration has implemented a rigorous multi-stage data quality assurance (DQA) pipeline.
The MAJORANA DEMONSTRATOR Experiment
The experiment is located 4,850 feet underground at the Sanford Underground Research Facility (SURF) to shield it from cosmic rays. It utilizes two modular arrays containing 44.1 kg of P-type Point-Contact (PPC) germanium detectors. Of this mass, 29.7 kg is enriched to 88% in $^{76}$Ge, while 14.4 kg of natural germanium serves as a background comparison. Ensuring the integrity of the data from these detectors requires constant monitoring of both the environment and the digital signals produced.
The Multi-Stage DQA Pipeline
Real-Time Monitoring and Run Ranking
The first line of defense is real-time environmental monitoring. Using a CouchDB database, the team tracks "slow controls" including liquid nitrogen levels, temperature, and humidity. Any instability in these parameters results in immediate flagging of the data.
Once a data "run" (typically lasting about one hour) is completed, it is transmitted to the NERSC supercomputing center. Within 30 minutes, automated scripts analyze the metadata to assign a quality rank: Gold, Silver, Bronze, or Bad. This rapid feedback allows the team to maintain a near-real-time understanding of detector health.
Waveform Reconstruction and Pathology Identification
Beyond metadata, the experiment records the full waveform of every pulse. This allows for the identification of specific "pathologies" that indicate instrumental noise rather than physical interactions. Common issues include:
- ADC Bit Flips: Random digital spikes that can be corrected during signal processing.
- Saturation: High-energy events may exceed the range of the high-gain electronics. In these cases, the system automatically substitutes data from a parallel low-gain channel to preserve the event's energy information.
Key Insights: Dual-Gain and Human Oversight
A critical feature of the MAJORANA electronics is the "dual-gain" strategy. By recording each detector signal through both high-gain and low-gain channels, the experiment recovers high-energy physics events that would otherwise be lost to electronic clipping.
Furthermore, while automation is central to the DQA pipeline, human oversight remains indispensable. DAQ shifters review the monitoring database four times daily to spot subtle irregularities that automated scripts might overlook. This "human-in-the-loop" approach ensures that environmental correlations, such as microphonic noise from liquid nitrogen fills, are precisely identified and surgically removed from the dataset.
Results and Future Directions
The DQA process has proven highly effective. Calibration data studies indicate that instrumental backgrounds affect less than 0.1% of physical events after the cleaning process is applied. This level of purity is essential for the experiment's sensitivity.
The modular and scalable nature of this DQA pipeline serves as a blueprint for future experiments. The lessons learned here are being directly applied to the LEGEND experiment, which aims to scale up to 1,000 kg of detectors. By refining these data quality techniques, the collaboration ensures that the path to discovering $0\nu\beta\beta$ remains clear of instrumental interference.
Summary updated