Constrained controllability of linear impulse differential systems

Z. Benzaid, Mario Sznaier

Abstract

Considers the following linear impulse differential control system x/spl dot/=A(t)x, t/spl ne/t/sub k/; /spl Delta/x=B/sub k/x(t/sub k/)+C/sub k/u/sub k/, t=t/sub k/; where the control sequences u/sub k/ belong to some set of admissible controllers that is restricted either by norm or by range. The authors then give a necessary and sufficient condition for global null controllability of time-varying systems and some sufficient conditions for global null controllability for time-invariant systems with special structures.<
BibTeX
@article{benzaid1994constrained,
  author = {Z. Benzaid and Mario Sznaier},
  title = {{Constrained controllability of linear impulse differential systems}},
  journal = {IEEE Trans. Automatic Control},
  year = {1994},
  doi = {10.1109/9.284894},
}

Loading related content...

Figure