Objective: To compare the slip method with culture ferment method in the detection of E.coli and for improving the accuracy of judgment of detection results.Methods:Slip method was used for monitoring the contamination status of cooking uten-sils and the slipswere put into lactose bile salts broth tubes for confirmation of the detection results by using ferment method.The re-sults were statistically analyzed.Results:Based on the judgment standard of GB14934-94,the sensitivity and specificity of the slip method were 79.2% and 97.7%,respectively.But the sensitivity and specificity were,based on the standard proposed by the author,97.1% and 78.2%,respectively.The difference of the sensitivities was significant(P0.001).Conclusion:The standard for judgment of results in detection of E.coli be modified so as to improve the accuracy of detection.