Abstract
An important initial step in fault detection for complex industrial systems is gaining an understanding of their health condition. Subsequently, continuous monitoring of this health condition becomes crucial to observe its evolution, track changes over time, and isolate faults. As faults are typically rare occurrences, it is essential to perform this monitoring in an unsupervised manner. Various approaches have been proposed not only to detect faults in an unsupervised manner but also to distinguish between different potential fault types. In this study, we perform a comprehensive comparison between two residual-based approaches: autoencoders, and the input-output models that establish a mapping between operating conditions and sensor readings. We explore the sensor-wise residuals and aggregated residuals for the entire system in both methods. The performance evaluation focuses on three tasks: health indicator construction, fault detection, and health indicator interpretation. To perform the comparison, we utilize the Commercial Modular Aero-Propulsion System Simulation (C-MAPSS) dynamical model, specifically a subset of the turbofan engine dataset containing three different fault types. All models are trained exclusively on healthy data. Fault detection is achieved by applying a threshold that is determined based on the healthy condition. The detection results reveal that both models are capable of detecting faults with an average delay of around 20 cycles and maintain a low false positive rate. While the fault detection performance is similar for both models, the input-output model provides better interpretability regarding potential fault types and the possible faulty components.
Introduction
In complex industrial systems like jet engines, faults are rare and varied "black swan" events. This scarcity makes supervised learning—training models on labeled examples of specific failures—impractical. Instead, engineers rely on unsupervised monitoring, where a model learns the characteristics of "healthy" operation and flags deviations as potential faults.
A common approach involves residual-based methods. These models predict expected sensor readings; the difference between these predictions and actual measurements constitutes the "residual." Spikes in residuals indicate potential system degradation. This study, conducted by researchers at ETH Zurich and EPFL, compares two primary architectures for generating these residuals: Autoencoders (AE) and Operating-Condition-based (OC) models, evaluating their performance in detection and diagnostic interpretability.
Methodology
The researchers compared two distinct neural network architectures to generate residuals and subsequent Health Indicators (HI):
- Autoencoder (AE) Model: A bottleneck architecture that takes all sensor data, compresses it into a low-dimensional latent space, and then attempts to reconstruct the original signal. The residual is the difference between the input and the reconstruction.
- Operating-Condition-based (OC) Model: A physics-informed approach that maps external operating conditions (e.g., altitude, Mach number, throttle angle) to internal engine sensors (e.g., temperature and pressure). The residual is the difference between the predicted sensor value and the actual measurement.
Health Indicators were constructed using two methods: an Aggregated HI ($h^A$), representing the Frobenius norm of all residuals for a system-wide view, and a Sensor-wise HI ($h_i^S$), tracking individual sensors for localized drift. Fault detection is triggered when the moving average of the HI exceeds a threshold defined by the healthy state ($μ + 3σ$).
Experimental Setup
The study utilized the N-CMAPSS dataset, a high-fidelity simulation of a commercial turbofan engine. The team focused on three sub-datasets representing distinct failure modes: Fan failure (DS04), High-Pressure Compressor (HPC) failure (DS05), and Low-Pressure Turbine (LPT) failure (DS07).
All models were trained exclusively on "healthy" data from the first 16 flight cycles of each engine unit to establish a baseline for normal operation.
Results and Discussion
Both models demonstrated robust performance, detecting faults with low false positive rates (FPR). However, significant differences emerged in interpretability and sensitivity:
- Detection Performance: Both models detected faults with an average delay of 15–17 cycles using sensor-wise indicators and 24–33 cycles using aggregated indicators. While sensor-wise indicators are faster, they are more prone to noise-induced false alarms.
- The Interpretability Advantage: The OC model significantly outperformed the AE in fault isolation. While AE models tend to "smear" fault information across all sensors during reconstruction, the OC model maintains a clear separation between cause (operating conditions) and effect (sensor readings).
- Fault Fingerprinting: Applying Principal Component Analysis (PCA) to the OC model's residuals revealed distinct clusters for different fault types (Fan, HPC, LPT). This allows the system to not only detect that a fault has occurred but also to identify which component is failing. The OC model consistently achieved higher Silhouette scores, confirming its superior diagnostic capabilities.
Conclusion
While both Autoencoders and Operating-Condition-based models are effective for unsupervised fault detection, the OC model provides a clear advantage for industrial applications requiring diagnostic depth. By accurately mapping operating conditions to expected sensor behavior, it generates residuals that serve as reliable "fingerprints" for specific failure modes. Future work will aim to extend these methods to non-steady-state flight phases and explore temporal architectures like Transformers to better capture the evolution of degradation over time.