This study compared the CBF measurements using single and multiple delay ASL on 28 children without neurological or cerebrovascular disorders. Results showed that CBF of multiple delay ASL was significantly higher than the values of single delay ASL by a mean of 18%. CBF of both ASL techniques increased with age.
BibTeX
@inproceedings{zhao2023comparing,
author = {Moss Zhao and Kristen W. Yeom and Elizabeth Tong and Rui Miguel Duarte and Michael E. Moseley and Greg Zaharchuk},
title = {{Comparing Single and Multiple Delays methods for ASL Perfusion Quantification on Pediatric Neuroimaging}},
booktitle = {Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition},
year = {2023},
doi = {10.58530/2022/1223},
}Loading related content...