Classification, Regression and Segmentation Directly from K-Space in Cardiac MRI

Ruochen Li, Jiazhen Pan, Youxiang Zhu, Juncheng Ni, Daniel Rueckert

Abstract

Traditional Cardiac Magnetic Resonance (CMR) analysis relies on reconstructed magnitude-only images, often discarding valuable phase information and suffering from artifacts in undersampled regimes. We present KMAE (K-space Masked Autoencoder), a Transformer-based framework designed to perform disease classification, phenotype regression, and tissue segmentation directly from raw k-space data. By leveraging the global receptive field of Transformers, KMAE captures the inherent structure of frequency-domain data. Our results demonstrate that KMAE matches or exceeds state-of-the-art image-domain methods while maintaining remarkable robustness to 8x undersampling.

Introduction

In clinical practice, CMR data is typically converted from complex-valued k-space (frequency domain) into magnitude-only images. This reconstruction process acts as a "middleman" that often discards phase information which could be diagnostically relevant for assessing flow and tissue movement. Furthermore, to reduce scan times, k-space is frequently undersampled. Standard AI models trained on reconstructed undersampled images often struggle with the resulting blurring and aliasing artifacts. This research explores a "k-space native" approach: training AI to interpret raw frequency data directly, thereby preserving all information and improving robustness to data sparsity.

Methods

The proposed KMAE architecture utilizes the Transformer's self-attention mechanism, which is uniquely suited for k-space data where every frequency point influences every spatial pixel. The pipeline is structured into three distinct phases:

  1. Pre-training: The model undergoes self-supervised learning on a reconstruction task using the K-GIN architecture to internalize the fundamental patterns of cardiac k-space.
  2. Feature Extraction: The pre-trained encoder is utilized to extract high-level representations from the input data.
  3. Task-Specific Decoders:
    • Classification and Regression: Extracted features are pooled and processed through fully connected layers to predict clinical categories (e.g., disease presence) or continuous values (e.g., heart volume).
  4. Segmentation: The model reconstructs the k-space, applies an Inverse Fast Fourier Transform (iFFT) to return to the image domain, and uses a 1x1 convolution to generate pixel-level masks.
Overview of the KMAE architecture showing pretraining, regression/classification, and segmentation pipelines.

Experimental Setup

The study utilized the UK Biobank (UKB) CMR dataset. Since UKB provides magnitude images, the authors generated synthetic k-space data by incorporating Gaussian B0 variations to simulate complex-valued acquisitions. The dataset was divided into three cohorts: a healthy subgroup (2,660 subjects), a cardiopathy subgroup (1,340 subjects), and a left ventricular dysfunction subgroup (937 subjects with ejection fraction <50%).

Results and Discussion

KMAE demonstrated strong performance across all three clinical tasks, particularly in challenging undersampled scenarios.

Segmentation and Regression

For myocardium segmentation, KMAE achieved a Dice score of 0.884, comparable to top-tier image-domain models. In regression tasks, such as predicting Left Ventricular End-Diastolic Volume (LVEDV), KMAE achieved a Mean Absolute Error (MAE) of 16.452, significantly outperforming the ResNet baseline (MAE: 27.188).

Example of a cardiac segmentation mask generated directly by the KMAE model.

Classification and Robustness

In identifying Left Ventricular Dysfunction, KMAE reached an accuracy of 76.33%, a substantial improvement over the ResNet baseline of 63.31%. Crucially, while image-domain methods typically see performance degradation as scan acceleration increases, KMAE's performance remained stable even at 8x undersampling. This suggests that the model effectively focuses on the low-frequency components that contain the most critical diagnostic information.

Conclusion

KMAE represents a shift toward "k-space native" AI for cardiac MRI. By bypassing image reconstruction, the model retains richer data and exhibits superior robustness to undersampling. Future work will focus on validating the model using real-world raw k-space data from MRI scanners and extending the architecture to handle multi-coil acquisitions common in clinical settings.

Summary updated

BibTeX
@inproceedings{li2024classification,
  author = {Ruochen Li and Jiazhen Pan and Youxiang Zhu and Juncheng Ni and Daniel Rueckert},
  title = {{Classification, Regression and Segmentation Directly from K-Space in Cardiac MRI}},
  booktitle = {MLMI @ MICCAI},
  year = {2024},
  doi = {10.1007/978-3-031-73284-3\_4},
}
Figure