TL;DR
Spotting a cavity isn’t a simple yes-or-no photo quiz; dentists zoom in from the whole jaw down to specific surfaces of individual teeth, mentally stitching together clues from multiple angles. This paper introduces CariesBench, a benchmark built from 3D dental scans to test whether Multimodal Large Language Models (MLLMs) can handle this hierarchical, multi-view diagnostic reasoning. It turns out today’s top AI models are surprisingly decent at scanning the big picture, yet hit a wall when forced to pinpoint damage on specific tooth surfaces.
What Problem Does This Paper Address?
When a dentist checks your teeth for caries (cavities), they don’t just declare "cavity detected" and call it a day. They localize the exact tooth, identify which anatomical surface is affected (chewing side, cheek side, between teeth), and grade the severity from faint enamel changes to deep cavities.
Modern digital dentistry uses 3D Intraoral Scans (IOS)—detailed geometric meshes of your mouth—which let clinicians inspect teeth from complementary viewpoints. While MLLMs are rapidly entering healthcare, existing dental AI benchmarks mostly rely on isolated 2D X-rays or single photos. None test whether an AI can maintain anatomical correspondence across multiple views of the same 3D tooth while reasoning hierarchically from the full dental arch down to individual surfaces. Without this, we don't know if AI can genuinely reason like a clinician or if it's just pattern-matching flat images.
Methods
To bridge 3D clinical reality and 2D-native MLLMs, the authors developed a pipeline that slices and renders 3D scans into standardized, multi-view 2D image grids:
- 3D-to-2D Multi-view Rendering: Full upper and lower arches are rendered into fixed $2 \times 3$ grids covering six angles. Using a pretrained segmentation model (
3DTeethSAM), individual teeth are isolated and rendered into multi-panel strips showing an overview alongside specific anatomical surfaces (buccal, lingual, mesial, distal, occlusal). Because every view comes from the same 3D mesh, spatial correspondence is exact. - Clinical Taxonomy: Labels follow a modified ICDAS-II clinical scale spanning eight states (
L0–L7), covering sound teeth, five progressive stages of decay, and restorations with or without secondary decay. - Hierarchical Task Design: Evaluation spans three families totaling 19 sub-tasks: Arch-level Clinical Screening (ACS) for broad dentition checks, Tooth-level Diagnostic Reasoning (TDR) featuring a structured five-step chain-of-thought (identifying views, morphology, texture, cross-view consistency, and final diagnosis), and Structured Clinical Decision-Making (SCD) using objective true/false and multiple-choice questions.
- IntraoralGPT: Beyond benchmarking 24 off-the-shelf MLLMs, the authors fine-tuned
Qwen3-VL-8B-Instructusing LoRA on the CariesBench training split to create a specialized baseline, IntraoralGPT.
Datasets
The paper introduces CariesBench, constructed from 5,932 3D intraoral scans collected from 2,966 patients at a university stomatological hospital (strictly split at the patient level to prevent data leakage). These scans yield 85,455 multi-view renderings and 133,994 VQA instances.
Ground-truth labels come directly from structured clinical exams rather than AI prose. GPT-4o was used strictly to phrase open-ended questions/answers from clinical records, audited by Gemini-2.5-Pro. Furthermore, dentists manually validated a stratified 20% subset, achieving strong inter-rater agreement ($\kappa = 0.86$). Unlike prior datasets like DENTEX (2D X-rays) or IOSVLM (arch-level 3D VQA), CariesBench uniquely unites arch-, tooth-, and surface-level multi-view reasoning.
Key Insights and Ideas
- The Global-to-Local Cliff: Across all 24 baseline models, performance drops sharply when zooming in from arch-level screening (ACS) to localized tooth-level reasoning (TDR). Models can spot general trouble across a jaw, but struggle to map visual defects to exact tooth surfaces across panels.
- Surface Localization is the True Bottleneck: Within tooth-level tasks, models perform well when simply verifying if a whole tooth is healthy, but crash when asked to grade specific surfaces—proving that cross-view anatomical integration, not image resolution, is where current MLLMs falter.
- Medical Pretraining Isn't a Silver Bullet: General-purpose commercial models outperformed medical- and dental-specialized MLLMs (like
DentVLMandOralGPT-Omni-7B) in zero-shot tests. Broad domain knowledge doesn't automatically teach a model 3D-grounded spatial correspondence.
Key Results
Evaluating 24 commercial, open-source, and medical MLLMs via task-parsed Clinical Accuracy revealed stark contrasts:
- Baseline Disparity: Across the 24 baselines, mean accuracy was 67.3% on ACS Overall compared to just 38.2% on TDR Overall—a 29.1 percentage-point drop.
- Surface vs. Whole Tooth: Even the strongest zero-shot baseline (
GPT-5.5, 63.6% 19-task average) scored 75.4% on binary Sound Tooth Verification, yet peaked at 31.8% on Surface Analysis and 30.5% on Full Tooth Scan. - Impact of Targeted Supervision: Fine-tuning
Qwen3-VL-8B-Instructinto IntraoralGPT boosted overall 19-task clinical accuracy from 52.7% to 69.5% (+16.8 points). Structured multiple-choice accuracy jumped by +35.5 points (to 72.7%), and TDR Overall rose from 34.4% to 44.7%—narrowly trailing zero-shotGPT-5.5(45.9%) on localized reasoning despite huge overall gains.
Limitations and Future Work
First, because ACS and TDR differ in answer formats, scoring units, and diagnostic complexity, the global-to-local accuracy gap is descriptive rather than a purely isolated measure of anatomical granularity. Second, even after targeted supervision, IntraoralGPT only reached ~30% accuracy on fine-grained surface analysis, showing that multi-view surface reasoning remains largely unsolved. Finally, CariesBench converts 3D meshes into 2D projections; future work aims to explore native 3D geometric reasoning and test generalization across diverse scanners and patient populations.
Summary updated