Bronchial segment matching in low-dose lung CT scan pairs
Lists
Only you see this
Abstract
Documenting any change in airway dimensions over time may be relevant for monitoring the progression of pulmonary diseases. In order to correctly measure the change in segmental dimensions of airways, it is necessary to locate the identical airway segments across two scans. In this paper, we present an automated method to match individual bronchial segments from a pair of low-dose CT scans. Our method uses the intensity information in addition to the graph structure as evidences for matching the individual segments. 3D image correlation matching technique is employed to match the region of interest around the branch points in two scans and therefore locate the matching bronchial segments. The matching process was designed to address the differences in airway tree structures from two scans due to the variation in tree segmentations. The algorithm was evaluated using 114 pairs of low-dose CT scans (120 kV, 40 mAs). The total number of segments matched was 3591, of which 99.7% were correctly matched. When the matching was limited to the bronchial segments of the fourth generation or less, the algorithm correctly identified all of 1553 matched segments.
BibTeX
@inproceedings{lee2009bronchial,
author = {Jaesung Lee and Anthony P. Reeves and David F. Yankelevitz and Claudia I. Henschke},
title = {{Bronchial segment matching in low-dose lung CT scan pairs}},
booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
year = {2009},
doi = {10.1117/12.812024},
}Loading related content...