Abstract
Bronchopulmonary dysplasia (BPD) remains a significant challenge in neonatal care, often requiring frequent monitoring via ionizing radiation. We present BPD-Neo, a novel open-source dataset comprising 40 high-resolution 3D MRI scans of neonates with BPD, complete with expert-labeled segmentations of the lungs and trachea and comprehensive clinical metadata. Using the nnU-Net framework, we establish benchmarks for automated segmentation, achieving a Mean Dice Score of 0.9512 for lungs and 0.6738 for the trachea. This dataset serves as a foundational resource for developing radiation-free, AI-driven diagnostic tools for preterm respiratory health.
Introduction
Bronchopulmonary dysplasia (BPD) is a chronic lung condition prevalent in preterm infants. Current clinical monitoring relies heavily on portable X-ray imaging, which, while accessible, exposes fragile neonates to ionizing radiation and provides limited two-dimensional structural information. Magnetic Resonance Imaging (MRI) offers a safer, three-dimensional alternative but is hindered by motion artifacts from rapid neonatal breathing and a lack of large-scale, annotated datasets for training automated analysis tools.
Methods
The BPD-Neo dataset consists of 40 neonatal subjects (18 male, 22 female) scanned using a 1.5 Tesla MRI. To mitigate motion artifacts without sedation, researchers employed the StarVIBE sequence (a free-breathing 3D stack-of-stars radial gradient echo). Annotations include expert-labeled NIfTI masks for the lungs and trachea. Clinical metadata, such as birth weight and gestational age, are provided, with BPD severity graded according to the 2019 Jensen criteria.
For benchmarking, the study utilized nnU-Net, a self-configuring deep learning framework. Both standard 3D U-Net and Residual Encoder (ResEnc) architectures were evaluated to establish baseline performance for automated segmentation of the neonatal respiratory system.
Results
Benchmarking revealed a significant disparity in segmentation performance between the lungs and the trachea.
- Lung Segmentation: The models achieved exceptional accuracy with a Mean Dice Score of 0.9512. AI-predicted lung volumes showed a high correlation with expert measurements (Pearson $r = 0.957$).
- Trachea Segmentation: Automated segmentation of the trachea proved challenging, yielding a Mean Dice Score of 0.6738. This difficulty stems from the small size of the airway and signal drop-offs in MRI coils positioned further from the chest.
Discussion
The "Trachea Challenge" highlights the need for specialized architectural improvements or loss functions to handle low signal-to-noise ratios in the upper airway. Furthermore, a slight decrease in accuracy was observed as infant length increased, suggesting that anatomical variability during growth is a critical factor for future model development.
Conclusion
BPD-Neo is the first open-source resource of its kind, aligning with modern clinical standards like the 2019 Jensen criteria. While lung segmentation is highly reliable, the trachea remains a difficult target for current AI models. Future work will focus on improving airway segmentation, discovering new biomarkers (e.g., lung volume to body surface area ratios), and validating models across multi-center data to ensure generalizability in clinical settings.
Summary updated