A Label Management Mechanism for Retinal Fundus Image Classification of Diabetic Retinopathy

Mengdi Gao, Ximeng Feng, Mufeng Geng, Zhe Jiang, Lei Zhu, Xiangxi Meng, Chuanqing Zhou, Qiushi Ren, Yanye Lu · DOI

Abstract

Deep neural networks (DNNs) have been widely applied in medical image classification, benefiting from their powerful mapping capability among medical images. However, existing deep learning-based methods depend on an enormous amount of carefully labeled images. Meanwhile, noise is inevitably introduced in the labeling process, degrading the performance of models. Hence, it is significant to devise robust training strategies to mitigate label noise in medical image classification tasks. In this work, we propose a novel Bayesian statistics guided label refurbishment mechanism (BLRM) for DNNs to prevent overfitting noisy images. BLRM utilizes maximum a posteriori probability (MAP) in Bayesian statistics and an exponentially time-weighted technique to selectively correct the labels of noisy images. The training images are purified gradually as training epochs progress. Comprehensive experiments on both synthetic noisy images (OCT & Messidor datasets) and real-world noisy images (ANIMAL-10N) demonstrate that BLRM refurbishes noisy labels selectively, curbing the adverse effects of noisy data. BLRM is effective across different noise ratios, independent of backbone architectures, and superior to state-of-the-art anti-noise methods.

Introduction

The success of deep learning in medical imaging, particularly in diagnosing conditions like Diabetic Retinopathy (DR) from retinal fundus images, is largely predicated on the availability of high-quality, expert-labeled datasets. However, in clinical practice, acquiring such data is a significant bottleneck. Labeling is expensive and time-consuming, and even expert annotations are subject to inter-observer variability and human error.

Because DNNs are universal function approximators, they possess a tendency to first learn simple, generalizable patterns before eventually "memorizing" incorrect or noisy labels. This memorization leads to poor generalization on clean test data. While existing strategies like sample discarding or loss weighting attempt to mitigate this, they often result in the loss of valuable information or the accumulation of error. This paper introduces the Bayesian statistics guided label refurbishment mechanism (BLRM), a robust training strategy designed to actively correct noisy labels during the training process.

The BLRM Framework

BLRM is designed as a "plug-and-play" module that can be integrated into standard DNN architectures. The mechanism operates through a multi-stage process to ensure that label correction only occurs once the model has achieved a sufficient level of reliability.

1. Warm-up and Start-up Conditions

To prevent the model from reinforcing early-stage errors, BLRM begins with a standard "warm-up" period using traditional cross-entropy loss. The refurbishment mechanism is only activated once a specific "start-up condition" is met—typically when the model reaches a stable state defined by validation accuracy and loss thresholds. This ensures the model has learned basic features before it attempts to judge the correctness of its own training labels.

2. Identifying Noisy Samples

Once active, BLRM employs the "low-loss trick." This observation suggests that DNNs learn clean, consistent samples faster than noisy ones. By partitioning a mini-batch based on loss values, the system can separate likely-clean samples from likely-noisy ones.

3. Bayesian Label Refurbishment

For samples identified as noisy or uncertain, BLRM estimates the true label using Maximum A Posteriori (MAP) probability. A critical innovation here is the use of an exponentially time-weighted function applied to the model's historical predictions for that specific image. Rather than treating all previous epochs equally, BLRM gives higher weight to the most recent predictions, reflecting the model's increasing expertise. The labels are then "refurbished"—updated to reflect this Bayesian estimation—and used for subsequent parameter updates.

Experimental Results

The authors validated BLRM across three distinct datasets, representing both synthetic noise and real-world annotation errors.

  • Synthetic Noise (OCT and Messidor): Using retinal optical coherence tomography and fundus images, the researchers introduced symmetric noise ranging from 10% to 40%. BLRM demonstrated remarkable resilience. On the OCT dataset with 40% noise, the mechanism improved accuracy by approximately 14% over the baseline. It consistently outperformed other state-of-the-art methods like Coteaching and JoCoR, which often struggle as noise levels exceed 30%.
  • Real-World Noise (ANIMAL-10N): To test efficacy against natural human error, the model was evaluated on the ANIMAL-10N benchmark. BLRM achieved a top accuracy of 82.6%, surpassing the default baseline of 79.4% and establishing its utility in non-synthetic environments.
  • Architecture Independence: The mechanism proved effective across various backbones, including VGG-16, ResNet-50, and Inception-V3, suggesting it is a versatile tool for different medical imaging tasks.

Clinical Interpretability

Beyond raw accuracy, the study investigated the clinical relevance of the features learned by the model. Using Class Activation Maps (CAMs), the researchers visualized which parts of an image the model prioritized for classification. Models trained with BLRM focused accurately on clinical lesions, such as microaneurysms and hemorrhages. In contrast, baseline models trained on noisy data were often distracted by non-clinical artifacts, such as nerve fiber reflections, which can lead to false positives in a diagnostic setting.

Conclusion

The Bayesian statistics guided label refurbishment mechanism (BLRM) provides a robust solution to the pervasive problem of label noise in medical imaging. By dynamically correcting labels based on historical prediction trends, BLRM prevents DNNs from memorizing errors while maximizing the utility of the available data. While future work is needed to address asymmetric noise—where specific classes are more likely to be confused than others—BLRM represents a significant step toward more reliable and interpretable automated medical diagnostics.

Summary updated

Abstract

Purpose: Deep neural networks (DNNs) have been widely applied in medical image classification, benefiting from its powerful mapping capability among medical images. However, these existing deep learning-based methods depend on an enormous amount of carefully labeled images. Meanwhile, noise is inevitably introduced in the labeling process, degrading the performance of models. Hence, it's significant to devise robust training strategies to mitigate label noise in the medical image classification tasks. Methods: In this work, we propose a novel Bayesian statistics guided label refurbishment mechanism (BLRM) for DNNs to prevent overfitting noisy images. BLRM utilizes maximum a posteriori probability (MAP) in the Bayesian statistics and the exponentially time-weighted technique to selectively correct the labels of noisy images. The training images are purified gradually with the training epochs when BLRM is activated, further improving classification performance. Results: Comprehensive experiments on both synthetic noisy images (public OCT & Messidor datasets) and real-world noisy images (ANIMAL-10N) demonstrate that BLRM refurbishes the noisy labels selectively, curbing the adverse effects of noisy data. Also, the anti-noise BLRM integrated with DNNs are effective at different noise ratio and are independent of backbone DNN architectures. In addition, BLRM is superior to state-of-the-art comparative methods of anti-noise. Conclusions: These investigations indicate that the proposed BLRM is well capable of mitigating label noise in medical image classification tasks.
BibTeX
@inproceedings{gao2022label,
  author = {Mengdi Gao and Ximeng Feng and Mufeng Geng and Zhe Jiang and Lei Zhu and Xiangxi Meng and Chuanqing Zhou and Qiushi Ren and Yanye Lu},
  title = {{A Label Management Mechanism for Retinal Fundus Image Classification of Diabetic Retinopathy}},
  booktitle = {Medical},
  year = {2022},
  doi = {10.1002/mp.15799},
}
Figure