Bayesian Inference for Brain Source Imaging with Joint Estimation of Structured Low-Rank Noise

Sanjay Ghosh, Chang Cai, Yijing Gao, Ali Hashemi, Stefan Haufe, Kensuke Sekihara, Ashish Raj, Srikantan S. Nagarajan

TL;DR

This paper introduces a novel Bayesian framework for brain source imaging that can simultaneously estimate brain activity and a specific type of structured noise (low-rank noise) without needing separate noise calibration data. This approach leads to more accurate reconstruction of brain signals, especially when dealing with correlated sensor noise common in EEG/MEG recordings.

What Problem Does This Paper Address?

Brain source imaging aims to pinpoint the location and timing of neural activity using non-invasive techniques like Electroencephalography (EEG) and Magnetoencephalography (MEG). A major hurdle is separating the faint brain signals from noisy sensor data. This noise isn't always random; it can be "structured," meaning it has patterns, often because of environmental interference or correlated sensor behavior. This structured noise, specifically low-rank noise, can significantly degrade the accuracy of brain activity reconstruction. Existing methods often struggle to effectively handle this type of noise, especially without requiring dedicated "baseline" recordings to characterize it. This paper tackles the challenge of jointly estimating both the brain activity and this low-rank noise covariance directly from the measurement data.

Methods

The authors propose a novel empirical Bayesian framework called "Low-rank Champagne." At its core, it's an iterative algorithm that refines estimates of both the brain source activity and the noise covariance in each step.

  • Generative Model: They start with a standard forward model: y = Lx + ε, where y is the sensor data, x is the brain activity, L is the lead-field matrix (mapping sources to sensors), and ε is the measurement noise.
  • Low-Rank Noise Model: The key innovation is modeling the noise covariance Λ⁻¹ as A = Σ(r) + σI, where Σ(r) is a low-rank component (capturing structured noise) and σI is a scaled identity matrix (representing uncorrelated noise). The low-rank component is further modeled using factor analysis.
  • Joint Estimation: The algorithm iteratively updates:
  • Brain Sources (x): Using a Bayesian inference approach, it estimates the posterior distribution of brain activity given the current noise estimate.
  • Noise Covariance (A): It estimates the noise covariance by applying factor analysis to the residual noise (the difference between the observed data and the activity predicted by the current brain source estimate). This is a crucial step as it allows for simultaneous estimation without separate calibration data.
  • Empirical Bayesian Approach: They use an empirical Bayesian approach, optimizing hyperparameters (like the variance of the source activity) by maximizing the marginal likelihood of the data.

Datasets

  • Simulated Data: The authors generated synthetic EEG/MEG data by simulating dipole sources with fixed orientations and damped sinusoidal time courses, then projecting them through a lead-field matrix and adding low-rank noise at various Signal-to-Noise Ratios (SNRs) and noise ranks.
  • Real MEG Data: They used real MEG data acquired from the Biomagnetic Imaging Laboratory at the University of California, San Francisco (UCSF) using a CTF Omega 2000 system. The lead field was calculated using a three-shell spherical model.
  • Benchmarks: They compare their method against sLORETA, a full-structure noise learning method (FUN), and a recent method by Cai et al. [12] (also referred to as "noise-learned Champagne").

Key Insights and Ideas

  • Joint Estimation is Crucial: The paper strongly suggests that effectively handling structured noise requires jointly estimating it with the brain activity, rather than treating them separately or assuming simple noise models.
  • Factor Analysis for Structured Noise: Using factor analysis to model the low-rank noise component is a novel and effective way to capture correlated sensor noise patterns.
  • No Baseline Data Needed: A significant advantage is that the algorithm can estimate the noise covariance directly from the measurement data, eliminating the need for separate, potentially difficult-to-obtain, baseline recordings. This makes the method more practical.
  • Robustness: The proposed algorithm is shown to be robust to initialization and computationally efficient.

Key Results

  • Superior Reconstruction: On simulated data, the "Low-rank Champagne" algorithm consistently outperformed benchmark methods (sLORETA, FUN, Cai et al. [12]) in terms of both A' and AP metrics across varying SNRs and noise ranks. For example, in Figure 3, it shows higher A' and AP scores across different SNRs.
  • Accurate Localization: On real auditory evoked field (AEF) data, the method successfully localized bilateral auditory activity in Heschl's gyrus, outperforming sLORETA, which struggled due to correlated sources.
  • Performance with Varying Rank: Figure 4 demonstrates that the proposed method maintains superior performance even as the rank of the noise covariance increases.

Limitations and Future Work

  • Computational Cost: While described as computationally efficient, the iterative nature of Bayesian inference can still be demanding for very large datasets or high-dimensional source spaces.
  • Model Assumptions: The effectiveness relies on the assumption that the structured noise can be well-approximated by a low-rank model. If the noise structure is more complex, performance might degrade.
  • Future Work: The paper doesn't explicitly detail future work, but potential directions could include extending the noise model to more general covariance structures, exploring different prior distributions for brain activity, or applying the framework to other neuroimaging modalities.

Summary updated

Abstract

ABSTRACT The inverse problem in brain source imaging is the reconstruction of brain activity from non-invasive recordings of electroencephalography (EEG) and magnetoencephalography (MEG). One key challenge is the efficient recovery of sparse brain activity when the data is corrupted by structured noise that is low-rank noise. This is often the case when there are a few active sources of environmental noise and the MEG/EEG sensor noise is highly correlated. In this paper, we propose a novel robust empirical Bayesian framework which provides us a tractable algorithm for jointly estimating a low-rank noise covariance and brain source activity. Specifically, we use a factor analysis model for the structured noise, and infer a sparse set of variance parameters for source activity, while performing Variational Bayesian inference for the noise. One key aspect of this algorithm is that it does not require any additional baseline measurements to estimate the noise covariance from the sensor data. We perform exhaustive experiments on both simulated and real datasets. Our algorithm achieves superior performance as compared to several existing benchmark algorithms.
BibTeX
@inproceedings{ghosh2023bayesian,
  author = {Sanjay Ghosh and Chang Cai and Yijing Gao and Ali Hashemi and Stefan Haufe and Kensuke Sekihara and Ashish Raj and Srikantan S. Nagarajan},
  title = {{Bayesian Inference for Brain Source Imaging with Joint Estimation of Structured Low-Rank Noise}},
  booktitle = {ISBI},
  year = {2023},
  doi = {10.1109/isbi53787.2023.10230330},
}

Loading related content...

Figure