Abstract
Stereoelectroencephalogram (SEEG) has been widely adapted to detect the electrical activity of patients with epilepsy. Due to the low-quality, large-amount, high-dimensionality characteristics of SEEG data, it is still challenging to comprehensively employ the SEEG signals to automatically and precisely determine the seizure onset zone (SOZ). This is because there is lack of an effective criterion for clinicians to select the target electrodes, which is of great importance for SOZ localization. We propose a SOZ localization method via analyzing the long-term SEEG monitoring for preoperative planning of epilepsy surgery. Considering that high frequency oscillations can reflect physiological brain activity of epileptic patients, we first extract the high-frequency features of the SEEG signals and utilize the convolutional neural network (CNN) to detect the interictal and seizure segments. Then we propose a novel criterion, namely adaptive high frequency epileptogenicity index (AHFEI), to determine the target electrodes. We compare our SEEG-determined target electrodes with three preoperative planning of successful focal epilepsy resective surgery cases, finding that most localization results of our method are in consistent with clinical successful decision making, while the performance of our method outperforms than the state-of-the-art method for SOZ localization. Our SEEG-determined SOZ localization method can assist clinicians in preliminarily selecting the potential target electrodes according to long-term SEEG data automatically and effectively.
Introduction
For patients with drug-resistant epilepsy, surgical resection of the Seizure Onset Zone (SOZ)—the specific brain tissue where seizures originate—is often the only path to a cure. However, identifying this "ground zero" is a significant clinical challenge. Clinicians typically rely on Stereoelectroencephalography (SEEG), which involves implanting electrodes deep within the brain to monitor electrical activity. While SEEG provides high-fidelity data, it creates a "big data" problem: clinicians must sift through massive amounts of high-dimensional, noisy data recorded over days or weeks. Currently, the lack of objective, automated criteria for identifying SOZ electrodes makes the process time-consuming and susceptible to human error.
Methodology
The researchers developed a multi-stage automated framework designed to streamline SOZ localization by analyzing long-term SEEG monitoring.
Preprocessing and Feature Extraction
Raw SEEG signals are filtered to isolate high-frequency oscillations (60–140 Hz), which serve as critical biomarkers for epileptic tissue. These signals are then converted into "high-frequency energy images" for further analysis.
CNN-Based Detection
A 5-layer Convolutional Neural Network (CNN) is employed to automatically distinguish between "interictal" (between seizures) and "ictal" (during seizure) segments. This automated classification replaces the labor-intensive manual annotation typically required by clinicians. The researchers opted for a relatively shallow architecture to prevent overfitting and ensure robust performance with limited seizure samples.
The AHFEI Criterion
The core innovation of this study is the Adaptive High Frequency Epileptogenicity Index (AHFEI). Unlike traditional indices that use fixed global thresholds, AHFEI calculates thresholds based on the specific Gaussian statistical distribution of each electrode's energy. This adaptive approach makes the system significantly more sensitive to local abnormalities across different brain regions. Finally, K-means clustering is used to group electrodes and highlight the primary targets for surgical resection.
Experimental Results
The study utilized a clinical dataset from three patients with drug-resistant focal epilepsy who achieved seizure-free outcomes (Engel Class I) following surgery. The recordings utilized 256-channel SEEG at a high sampling rate of 2048 Hz, spanning 252 to 412 hours per patient and capturing 5 to 8 seizure events per case.
The AHFEI method consistently outperformed the previous state-of-the-art HFEI method across several metrics:
- Accuracy: Achieved up to 97.22% for Patient 1, significantly higher than the ~89% achieved by traditional methods.
- Sensitivity: Showed marked improvement, reaching 86.96% in Patient 1 compared to the 59.09% baseline.
- Clinical Consistency: The algorithmically identified electrodes showed high overlap with those manually selected by neurosurgeons for successful surgeries, demonstrating its potential as a "second opinion" tool.
Discussion and Conclusion
A key insight from this research is that incorporating both seizure and interictal data yields superior localization results. This suggests that the SOZ leaves a detectable high-frequency "fingerprint" even when the patient is not actively seizing. By assuming a Gaussian distribution of energy for each electrode, the AHFEI model can identify outliers (the SOZ) more reliably than global thresholding methods.
While this preliminary study is promising, it is limited by a small sample size and a focus on focal epilepsy. Future work will involve validating the AHFEI on larger, more diverse patient cohorts and integrating the tool into comprehensive clinical decision systems that combine electrical data with neuroimaging like MRI and PET scans. This automated SOZ localization method has the potential to significantly improve preoperative planning and surgical outcomes for epilepsy patients.
Summary updated