Automatic Facial Landmark Localization in Clinical Populations - Improving Model Performance with a Small Dataset

Diego L. Guarín, Babak Taati, Tessa Hadlock, Yana YunusovaResearch Square 2020 · DOI

Introduction

Facial landmark localization (FLL)—the automated identification of key anatomical points like eye corners or mouth edges—is a foundational step in computer vision applications, particularly for objective clinical assessments. However, most state-of-the-art models suffer from significant "algorithmic bias." Because these models are typically trained on "in-the-wild" datasets featuring young, healthy individuals with symmetrical facial movements, their performance degrades when applied to older adults or patients with conditions like facial palsy, stroke, or Parkinson’s disease.

For clinicians, this bias is a major barrier. Automated tools could revolutionize the tracking of disease progression or surgical recovery, but if a model cannot accurately detect an asymmetrical smile or a drooping eyelid, the resulting data is unreliable. This study investigates a practical solution: how much clinical data is actually required to fine-tune a model and bridge this performance gap?

Methods and Datasets

The researchers employed the Facial Alignment Network (FAN), a popular Convolutional Neural Network (CNN). Their strategy utilized transfer learning, where a model pre-trained on 230,000 standard facial images was fine-tuned using clinical data. Specifically, the first four stages of the network were "frozen" to preserve general feature detection (edges, shapes), while the final "hourglass" layers were updated.

Data Collection

The study utilized two primary datasets:

  1. Dataset 1: 1,600 high-resolution photographs from 200 patients with unilateral facial paralysis. Each patient performed eight standardized facial expressions (e.g., full-effort smile, eyebrow elevation).
  2. Dataset 2: 480 photographs from 60 subjects (50 patients with varying paralysis severity and 10 healthy controls) used as an independent benchmark.

All images were manually annotated with 68 facial landmarks by three independent experts to establish a "ground truth."

Manual annotation of 68 facial landmarks on a patient with facial palsy, illustrating the challenge of asymmetrical features.

Experimental Design

To determine the optimal amount of data, the researchers created ten subgroups for fine-tuning, ranging from a single patient (8 images) to 160 patients (1,280 images). They also investigated "annotator bias" by comparing models trained on data from single versus multiple human experts.

Key Results

The study measured performance using the Normalized Root Mean Squared Error (NRMSE).

  • The Power of Minimal Data: Fine-tuning with just 8 photographs from a single patient significantly improved performance across the entire clinical population compared to the out-of-the-box model (dropping error from 11.5% to 10.1%).
  • The 40-Patient Threshold: A clear plateau in performance was observed. While accuracy improved as more data was added, gains ceased to be statistically significant after 40 patients (320 images), where the error rate reached a minimum of 6.7%.
  • Mitigating Severity Bias: The pre-trained model performed worst on patients with complete paralysis (12.3% error). Fine-tuning effectively leveled the playing field, reducing error in these severe cases to 7.1%.
  • Addressing Annotator Bias: Models trained on a single annotator's data developed a specific "accent" or bias. Averaging labels from multiple annotators before training neutralized this effect, resulting in a more robust model.

Discussion and Conclusion

This research demonstrates that the algorithmic bias inherent in general-purpose facial models can be effectively removed using relatively small clinical datasets. The finding that 320 images from 40 patients is sufficient for optimal fine-tuning is highly encouraging for clinical researchers who often face recruitment challenges.

While the study focused on facial palsy in controlled settings, these results suggest a viable path forward for the automatic assessment of orofacial function in other populations, such as those affected by stroke or Parkinson’s disease. Future work will need to validate if these improvements hold for "in-the-wild" video recordings or lower-quality mobile imagery.

Summary updated

Abstract

<title>Abstract</title> Background Automatic facial landmark localization in videos is an important first step in many computer vision applications, including the objective assessment of orofacial function. Convolutional neural networks (CNN) for facial landmarks localization are typically trained on faces of healthy and young adults, so model performance is inferior when applied to faces of older adults or people with diseases that affect facial movements, a phenomenon known as algorithmic bias. Fine-tuning pre-trained CNN models with representative data is a well-known technique used to reduce algorithmic bias and improve performance on clinical populations. However, the question of how much data is needed to properly fine-tune the model remains. Methods In this paper, we fine-tuned a popular CNN model for automatic facial landmarks localization using different number of manually annotated photographs from patients with facial palsy and evaluated the effects of the number of photographs used for model fine-tuning in the model performance by computing the normalized root mean squared error between the facial landmarks positions predicted by the model and those provided by manual annotators. Furthermore, we studied the effect of annotator bias by fine-tuning and evaluating the model with data provided by multiple annotators. Results Our results showed that fine-tuning the model with as little as 8 photographs from a single patient significantly improved the model performance on other individuals from the same clinical population, and that the best performance was achieved by fine-tuning the model with 320 photographs from 40 patients. Using more photographs for fine-tuning did not improve the model performance further. Regarding the annotator bias, we found that fine-tuning a CNN model with data from one annotator resulted in models biased against other annotators; our results also showed that this effect can be diminished by averaging data from multiple annotators. Conclusions It is possible to remove the algorithmic bias of a\textbf{depth} CNN model for automatic facial landmark localization using data from only 40 participants (total of 320 photographs). These results pave the way to future clinical applications of CNN models for the automatic assessment of orofacial function in different clinical populations, including patients with Parkinson’s disease and stroke.
BibTeX
@inproceedings{guarin2020automatic,
  author = {Diego L. Guarín and Babak Taati and Tessa Hadlock and Yana Yunusova},
  title = {{Automatic Facial Landmark Localization in Clinical Populations - Improving Model Performance with a Small Dataset}},
  booktitle = {Research Square},
  year = {2020},
  doi = {10.21203/rs.3.rs-19405/v1},
}
Figure