TL;DR
This systematic review synthesizes research on automated nonmelanoma skin cancer (NMSC) detection using digital images and machine learning. While many studies show high diagnostic accuracy, often exceeding that of dermatologists, most suffer from significant methodological limitations, highlighting the need for more robust clinical validation before real-world implementation.
What Problem Does This Paper Address?
Nonmelanoma skin cancer (NMSC) is the most common malignancy globally. Early and accurate diagnosis is crucial to prevent morbidity. While visual inspection by dermatologists is the primary diagnostic method, differentiating NMSC from benign skin lesions can be challenging, leading to unnecessary biopsies. Computer-aided diagnosis (CAD) systems, particularly those using machine learning (ML) on digital images, offer a promising avenue to improve diagnostic accuracy and accessibility. However, research specifically on automated NMSC detection using these methods has been fragmented, and the quality of evidence for their diagnostic accuracy has not been systematically evaluated. This paper aims to address this gap by reviewing and assessing the existing literature on image-based ML models for NMSC detection.
Methods
The authors conducted a systematic review by searching eight major scientific databases for studies on NMSC detection using image-based ML models. Two independent reviewers screened articles, assessed the level of evidence using a five-tier rating system, and evaluated the risk of bias and applicability using the QUADAS-2 tool. The review focused on studies classifying NMSC versus benign lesions using digital images and machine learning.
Datasets
The paper does not introduce new datasets. Instead, it reviews studies that utilized various datasets for training and evaluating their NMSC detection models. These datasets were typically composed of digital images of skin lesions, often acquired through dermoscopy or standard digital photography. The images were usually annotated with biopsy-proven diagnoses. The size of the NMSC test sets varied significantly, ranging from as few as ten lesions to over 700. The benign lesions used for comparison included a wide array of mimics such as seborrheic keratoses (SKs), nevi, actinic keratoses (AKs), and other benign skin conditions.
Key Insights and Ideas
- High Potential, Low Evidence Quality: The most striking finding is the high reported diagnostic accuracy of many ML models, often surpassing average dermatologist performance. However, this is frequently coupled with substantial methodological limitations, meaning the "high accuracy" might not be as reliable as it seems.
- NMSC Research Lagging Melanoma: Despite NMSC's prevalence, research in automated detection lags behind that for melanoma, which has seen more extensive systematic reviews.
- "In Silico" Limitations: All reviewed studies were conducted "in silico" (using computer simulations or existing datasets), meaning they haven't been tested in real-time clinical settings with human-computer interaction. This is a major hurdle for practical implementation.
- Data-Driven Models Show Promise: Models that bypass manual feature engineering and rely on fully automated analysis of raw pixel data, often pre-trained on massive image datasets, represent a more promising direction for overcoming the challenge of variable clinical presentations.
- Benign Mimics Matter: The choice of benign lesions used for comparison is critical. While some studies used only AKs (a precursor to CSCC), others used a broader range of benign mimics, which is more representative of clinical practice.
Key Results
- 39 Studies Reviewed: The review analyzed 39 studies focusing on automated NMSC detection using digital images and ML.
- Model Focus: The majority of models were designed to detect basal cell carcinoma (BCC) (24 studies), with fewer focusing on squamous cell carcinoma (CSCC) (2 studies) or both (13 studies).
- High Diagnostic Accuracy: Reported diagnostic accuracies ranged from 72% to 100%, with areas under the receiver operating characteristic curve (AUROC) from 0.832 to 1.
- Dermatologist Comparison: Six studies directly compared their classifiers to dermatologists, with ML models generally showing higher performance. For instance, one study showed an ANN classifier achieving 80.3% accuracy for BCC and 82.5% for CSCC, compared to dermatologists' 64.8% and 59.5%, respectively.
- Methodological Limitations: Common issues included the use of non-consecutive samples, overlapping training and test sets, and non-biopsy-proven reference standards for benign lesions. Many studies also lacked sufficient detail on preprocessing methods.
Limitations and Future Work
The authors acknowledge several limitations:
- "In Silico" Studies: All studies were conducted in silico, lacking real-time clinical testing and human-computer interface design. This is the most significant limitation, as it prevents assessment of feasibility in actual clinical practice.
- Methodological Weaknesses: Many studies suffered from issues like non-consecutive samples, lack of independence between training and testing sets, and the use of uncertain reference standards.
- Limited Reporting: Some studies did not provide sufficient detail on preprocessing methods or reported only specific metrics (e.g., F-measure) rather than standard accuracy or AUROC.
- Lack of Statistical Significance: Comparisons to dermatologists often lacked P-values, making it uncertain if the observed performance differences were statistically significant.
The authors strongly advocate for clinical studies to assess the feasibility and real-time performance of these NMSC detection models. Future work should focus on developing systems with complete human-computer interfaces and rigorously testing them in clinical trials, similar to what has been done for melanoma detection systems. Further research is also needed to address the preprocessing challenges and explore more data-driven approaches.