Autocorrelated process monitoring using triggered cuscore charts

Lianjie Shu, Daniel W. Apley, Fugee TsungQuality 2002

TL;DR

This paper introduces a "triggered Cuscore chart" to improve the detection of mean shifts in autocorrelated processes. By using a CUSUM chart or a GLRT to estimate the time of a fault, the Cuscore chart can be initialized more accurately, leading to faster and more reliable detection compared to traditional methods.

What Problem Does This Paper Address?

Traditional statistical process control (SPC) charts, like Shewhart, CUSUM, or EWMA, struggle when data exhibits autocorrelation. This is because these charts assume independent data points, and autocorrelation can lead to an increased rate of false alarms. While methods exist to handle autocorrelated data, such as using time series residuals, they often fail to fully leverage the "fault signature" – the characteristic pattern of the residuals when a fault occurs. The Cuscore chart is designed to use this signature, but its effectiveness is highly dependent on knowing the exact time of the fault to align its detector with the signature. Since this time is usually unknown, a mismatch can occur, degrading performance. This paper aims to bridge this gap by proposing a "triggered" Cuscore chart that intelligently estimates the fault's occurrence time to optimize the Cuscore's alignment with the fault signature.

Methods

The core innovation is the "triggered Cuscore chart." Instead of initializing the Cuscore chart at the beginning of data collection (which assumes the fault, if it occurs, happens early), this new approach uses an auxiliary "trigger" statistic to estimate the fault's time of occurrence ($\hat{\tau}$).

  1. Trigger CUSUM: The primary triggering mechanism proposed is a standard CUSUM chart applied to the residuals. When this CUSUM chart signals an anomaly (exceeds a decision interval $H$), the time of the last reset to zero is identified as the estimated fault time ($\hat{\tau}$). The Cuscore chart is then initialized retroactively at this estimated time.
  2. CUSUM-triggered Cuscore: Once $\hat{\tau}$ is estimated, the CUSUM trigger is stopped, and the Cuscore chart takes over, using a detector ($r_t$) that is aligned with the expected fault signature at time $\hat{\tau}$.
  3. GLRT-based Trigger: A more sophisticated triggering method is also explored, using a Generalized Likelihood Ratio Test (GLRT) to estimate $\hat{\tau}$ from the residuals. This method aims to provide a more statistically rigorous estimate of the fault time.

The paper compares the performance of the CUSUM-triggered Cuscore chart against the standard Cuscore chart (initialized at $t=1$) and a residual-based CUSUM chart.

Datasets

The paper uses simulated data generated from ARMA(1,1) processes to evaluate the performance of the proposed charts. Two specific ARMA(1,1) models (Model 1 and Model 2) with different autocorrelation structures and fault signatures are used. No real-world datasets are presented.

Key Insights and Ideas

  • The "Fault Signature" is Key: The dynamic pattern of residuals after a fault (the "fault signature") contains valuable information for detection. Traditional charts ignore this, while the Cuscore chart aims to use it, but only if perfectly aligned.
  • Timing is Everything for Cuscore: The performance of the Cuscore chart is highly sensitive to the accuracy of its initialization time. A mismatch between the initialization time and the actual fault time significantly degrades its ability to detect faults quickly.
  • Triggering Solves the Timing Problem: By using a separate "trigger" mechanism (like a CUSUM or GLRT) to estimate the fault time, the Cuscore chart can be initialized much closer to the actual event, dramatically improving its detection speed and reliability.
  • CUSUM as a Simple, Effective Trigger: A standard CUSUM chart, when used solely as a trigger (not for direct signaling), proves to be a surprisingly effective and simple way to estimate the fault occurrence time.
  • GLRT Offers Refinement: While more complex, using a GLRT for estimating the fault time can further enhance the triggered Cuscore chart's performance, though the gains might be marginal compared to the CUSUM trigger.

Key Results

  • Superior Performance: The CUSUM-triggered Cuscore chart consistently outperforms both the standard Cuscore chart and the residual-based CUSUM chart, especially when the fault occurs later in the process (i.e., when the standard Cuscore initialization is far from the actual fault time).
  • Faster Detection: Simulation results show significantly lower Average Run Lengths (ARLs) for the triggered Cuscore chart, indicating faster detection of mean shifts. For instance, in one scenario, the triggered chart achieved a detection lag of 6 observations, compared to 14 for the other charts.
  • Robustness to Fault Timing: The triggered Cuscore chart's performance is much less affected by the actual time of the fault occurrence compared to the standard Cuscore chart.
  • Model Dependence: The effectiveness of the fault signature and thus the charts can depend on the specific ARMA model parameters.

Limitations and Future Work

  • Complexity of GLRT Trigger: While the GLRT-based trigger offers potential performance improvements, it is noted as being slightly more complicated to implement than the CUSUM trigger.
  • Optimal Parameter Selection: Determining the optimal reference values ($k$) and decision intervals ($H$, $h$) for the trigger and Cuscore charts can be complex and depends on various factors, including the expected fault magnitude and timing. The paper provides guidelines but acknowledges that truly optimal selection is challenging.
  • Focus on Step Mean Shifts: The study primarily focuses on detecting step mean shifts. The authors suggest that the triggered Cuscore framework can be extended to other fault types, such as sudden spikes, by adapting the fault signature calculation.
  • Further Exploration of Triggers: While CUSUM and GLRT are explored, other sophisticated triggering mechanisms could potentially be investigated.

Summary updated

Abstract

Abstract Some of the most widely‐investigated control charting techniques for autocorrelated data are based on time series residuals. If the mean shift in the autocorrelated process is a sudden step shift, the resulting mean shift in the residuals is time varying and has been referred to as the fault signature. Traditional residual based charts, such as a Shewhart, CUSUM, or EWMA on the residuals, do not make use of the information contained in the dynamics of the fault signature. In contrast, methods such as the Cuscore chart or Generalized Likelihood Ratio Test (GLRT) do incorporate this information. In order for the Cuscore chart to fully benefit from this, its detector coefficients should coincide with the fault signature. This is impossible to ensure, however, since the exact form of the fault signature depends on the time of occurrence of the mean shift, which is generally not known a priori . Any mismatch between the detector and the fault signature will adversely affect the Cuscore performance. This paper proposes a CUSUM‐triggered Cuscore chart to reduce the mismatch between the detector and fault signature. A variation to the CUSUM‐triggered Cuscore chart that uses a GLRT to estimate the mean shift time of occurrence is also discussed. It is shown that the triggered Cuscore chart performs better than the standard Cuscore chart and the residual‐based CUSUM chart. Examples are provided to illustrate its use. Copyright © 2002 John Wiley & Sons, Ltd.
BibTeX
@inproceedings{shu2002autocorrelated,
  author = {Lianjie Shu and Daniel W. Apley and Fugee Tsung},
  title = {{Autocorrelated process monitoring using triggered cuscore charts}},
  booktitle = {Quality},
  year = {2002},
  doi = {10.1002/qre.492},
}
Figure