AnesSuite: A Comprehensive Benchmark and Dataset Suite for Anesthesiology Reasoning in LLMs

Xiang Feng, Wentao Jiang, Zengmao Wang, Yong Luo, Pingbo Xu, Baosheng Yu, Hua Jin, Jing Zhang

Abstract

The application of large language models (LLMs) in the medical field has garnered significant attention, yet their reasoning capabilities in specialized domains like anesthesiology remain underexplored. We introduce AnesSuite, the first comprehensive dataset suite designed for anesthesiology reasoning. It features AnesBench, a bilingual benchmark assessing three levels of reasoning: factual retrieval (System 1), hybrid reasoning (System 1.x), and complex decision-making (System 2). The suite also includes datasets for continued pre-training (CPT), supervised fine-tuning (SFT), and reinforcement learning with verifiable rewards (RLVR). Leveraging this suite, we developed Morpheus, the first baseline model collection for anesthesiology. Morpheus achieves performance rivaling much larger models and demonstrates enhanced reasoning across general medical benchmarks. Both AnesSuite and Morpheus are open-sourced to facilitate further research.

Introduction

While Large Language Models (LLMs) have made significant strides in general medicine, their capabilities in high-stakes, specialized fields like anesthesiology remain largely untested. Anesthesiology demands complex, context-aware clinical decision-making—simultaneously managing airways, cardiovascular stability, and perioperative fluctuations. Existing medical benchmarks often lack the granularity to evaluate the multi-step, higher-order reasoning (System 2 thinking) required for real-world anesthetic practice. AnesSuite addresses this gap by providing a full-stack infrastructure for both evaluation and training.

The AnesSuite Framework

AnesSuite is composed of four distinct components designed to support the entire lifecycle of model development:

  • AnesBench (Evaluation): A bilingual (English/Chinese) benchmark of 7,972 multiple-choice questions. Approximately 20-30% of these questions require higher-order System 1.x or System 2 reasoning.
  • AnesCorpus (Continued Pre-training): A collection of over 2.4 million cleaned, domain-specific documents.
  • AnesQA (Supervised Fine-Tuning): 20,713 high-quality Question-Answer pairs derived from domain literature.
  • AnesR1 (Reinforcement Learning): 10,287 verifiable questions paired with detailed Chain-of-Thought (CoT) reasoning trajectories for RLVR.
Overview of AnesSuite components and the Morpheus training pipeline.

Methodology: Developing Morpheus

Using AnesSuite, we developed the Morpheus model family (7B, 14B, and 32B parameters) based on the Qwen2.5 architecture. The training process involved initial Supervised Fine-Tuning (SFT) followed by Group Relative Policy Optimization (GRPO). This reinforcement learning technique utilizes verifiable rewards to incentivize the model to generate accurate and structured Chain-of-Thought reasoning. We categorized medical questions into three levels based on Kahneman’s cognitive framework: System 1 (factual retrieval), System 1.x (hybrid reasoning), and System 2 (complex decision-making).

Key Insights and Scaling Laws

Our comprehensive evaluation of over 50 LLMs revealed several critical insights into the nature of specialized medical reasoning:

  • The System 2 Bottleneck: Even frontier models like GPT-4o struggle with System 2 anesthesiology questions, typically scoring between 50% and 60%. This indicates that general medical knowledge does not automatically translate to specialized clinical reasoning.
  • Scaling and Diminishing Returns: While performance generally improves with model size, the gains for complex System 2 tasks are less pronounced than for factual recall. As shown in the scaling analysis, System 2 accuracy remains consistently lower across the model size spectrum.
  • Reasoning Length: Generating longer CoT responses significantly boosts accuracy for System 2 questions, whereas it provides negligible benefits for System 1 factual recall.
  • Cross-lingual Challenges: Continued Pre-Training (CPT) on domain data can lead to "catastrophic forgetting" in multilingual contexts, sometimes boosting English performance at the expense of Chinese accuracy.
Scaling laws for anesthesiology reasoning across System 1, 1.x, and 2 tasks in AnesBench-English.

Results

The specialized Morpheus-32B model achieved 72% overall accuracy on AnesBench-English, matching the performance of the much larger Qwen2.5-72B-Instruct. Furthermore, training on anesthesiology reasoning (AnesR1) unexpectedly improved performance on out-of-distribution general medical benchmarks (e.g., MedQA) and general-domain benchmarks (e.g., MMLU), suggesting that deep reasoning in a niche specialty can elevate a model's general reasoning floor.

Limitations and Future Work

Current limitations include the reliance on abstract text scenarios rather than real-world clinical logs and the lack of multi-modal data. Clinical anesthesiology depends heavily on real-time monitors and waveforms; future iterations of AnesSuite will aim to incorporate these modalities to better reflect the perioperative environment.

Summary updated

Abstract

The application of large language models (LLMs) in the medical field has garnered significant attention, yet their reasoning capabilities in more specialized domains like anesthesiology remain underexplored. To bridge this gap, we introduce AnesSuite, the first comprehensive dataset suite specifically designed for anesthesiology reasoning in LLMs. The suite features AnesBench, an evaluation benchmark tailored to assess anesthesiology-related reasoning across three levels: factual retrieval (System 1), hybrid reasoning (System 1.x), and complex decision-making (System 2). Alongside this benchmark, the suite includes three training datasets that provide an infrastructure for continued pre-training (CPT), supervised fine-tuning (SFT), and reinforcement learning with verifiable rewards (RLVR). Leveraging this suite, we develop Morpheus, the first baseline model collection for anesthesiology reasoning. Despite undergoing limited training with SFT and group relative policy optimization (GRPO), Morpheus not only achieves substantial improvements in anesthesiology that rival larger-scale models, but also demonstrates enhanced reasoning capabilities across general medical and broad-domain benchmarks. Furthermore, through comprehensive evaluations and experiments, we analyze the key factors influencing anesthesiology reasoning performance, including model characteristics, training strategies and training data. Both AnesSuite and Morpheus will be open-sourced at https://github.com/MiliLab/AnesSuite.
BibTeX
@inproceedings{feng2026anessuite,
  author = {Xiang Feng and Wentao Jiang and Zengmao Wang and Yong Luo and Pingbo Xu and Baosheng Yu and Hua Jin and Jing Zhang},
  title = {{AnesSuite: A Comprehensive Benchmark and Dataset Suite for Anesthesiology Reasoning in LLMs}},
  booktitle = {International Conference on Learning Representations},
  year = {2026},
  url = {https://openreview.net/forum?id=iKRQMeC7yO},
}
Figure