Introduction
Computed Tomography (CT) is a cornerstone of modern medical diagnostics, yet the ionizing radiation associated with high-dose scans poses potential health risks to patients. To mitigate these risks, clinicians often utilize low-dose CT (LDCT) protocols. However, reducing radiation dose introduces significant noise and artifacts that can obscure fine anatomical details and compromise diagnostic accuracy. While deep learning-based denoising methods have emerged as a solution, many existing models suffer from "semantic blindness"—treating all pixels equally regardless of the underlying tissue—and a tendency toward over-smoothing, which results in a loss of clinically vital texture.
To address these limitations, we present ALDEN (Anatomy-aware LDCT DENoising), a framework that leverages the latent knowledge within Pretrained Vision Models (PVMs) to achieve anatomy-aware denoising. By integrating hierarchical semantic features from foundation models like DINOv2 and MedSAM, ALDEN preserves tissue-specific patterns and maintains anatomical consistency without requiring manual labels.
The ALDEN Framework
ALDEN is built upon a Generative Adversarial Network (GAN) architecture, enhanced by two novel components designed to enforce anatomical awareness: the Anatomy-Aware Discriminator (AAD) and Semantic-Guided Contrastive Learning (SCL).
Anatomy-Aware Discriminator (AAD)
Traditional discriminators evaluate images globally, often failing to distinguish between noise and fine anatomical structures. The AAD addresses this by incorporating hierarchical semantic features extracted from a reference normal-dose CT (NDCT) scan using a PVM. These features are fused with the discriminator's internal representations via an Attention-based Feature Fusion (AFF) module. This cross-attention mechanism allows the discriminator to dynamically focus on specific tissues, enabling a more nuanced, tissue-specific evaluation of realism.
Semantic-Guided Contrastive Learning (SCL)
To ensure that the denoised output remains faithful to the original anatomy, the SCL module utilizes contrastive learning to align features in a high-dimensional semantic space. The module employs three types of pairs:
- Positive Pairs: These align features from the same anatomical location in the denoised image and the ground-truth NDCT, ensuring structural fidelity.
- Dual Negative Pairs: The first negative pair pushes the model away from the noise patterns inherent in the LDCT input. The second negative pair prevents "anatomical misalignment" by contrasting features against mismatched locations, ensuring that structures like organs or bones do not shift during the denoising process.
Experimental Results
Quantitative and Perceptual Performance
The ALDEN framework was evaluated on two benchmark datasets: the Mayo2016 dataset and the Multi-center CT Denoising (MCTD) dataset. ALDEN achieved state-of-the-art (SOTA) performance across multiple metrics:
- Perceptual Fidelity: On the MCTD dataset, ALDEN-DINOv2 reduced the Learned Perceptual Image Patch Similarity (LPIPS) score by 44.1% to 59.7% compared to previous leading methods such as CoreDiff and ASCON. This indicates a significant reduction in the "plastic" look common in traditional denoising.
- Signal Accuracy: The model reached a Peak Signal-to-Noise Ratio (PSNR) of 33.71 dB on the Mayo2016 dataset, outperforming both standard CNN-based and modern Diffusion-based architectures.
Downstream Utility: Multi-Organ Segmentation
To validate the clinical utility of the denoised images, the researchers performed a downstream multi-organ segmentation task using the TotalSegmentator dataset, which includes 117 anatomical structures. ALDEN-denoised images significantly improved the performance of segmentation models, particularly in high-noise scenarios. The model achieved a higher Dice Similarity Coefficient (DSC) than competing methods, outperforming the next best approach by 1.07%, demonstrating that ALDEN effectively preserves the semantic boundaries required for automated diagnostic tools.
Discussion and Conclusion
A key insight from this research is the efficacy of foundation models like DINOv2 in medical contexts. Despite being trained on natural images (e.g., landscapes and animals), these models possess latent anatomical understanding that can be successfully transferred to CT imaging. By leveraging these "anatomy teachers," ALDEN moves beyond simple pixel-wise reconstruction to prioritize perceptual and structural integrity.
While the integration of large PVMs introduces computational overhead during the training phase, the resulting model offers a substantial leap forward in producing high-quality, diagnostically reliable CT images from low-dose acquisitions. Future work will focus on optimizing the architecture for real-time clinical inference and testing the model's robustness against rare pathologies and varied scanner artifacts.
Summary updated