Airflow field simulation model building and application for aerobic compost using CFD

Qiongyi Cheng, Haibo Meng, Haibin Zhou, Yujun Shen, Hongsheng Cheng, Jingtao Ding, Shihao Zhao, Shance HouInternational Journal of Agricultural and Biological Engineering 2021 · DOI

Abstract

Composting is a cost-effective strategy for transforming animal waste into stabilized fertilizer, yet its efficiency is often limited by uneven oxygen distribution. In zones with weak aeration, anaerobic fermentation can occur, leading to odors and poor product quality. Due to the extremely low air speeds and harsh internal conditions of compost piles, direct measurement of airflow is difficult. This study utilizes Computational Fluid Dynamics (CFD) to model and investigate the airflow field within a compost pile. By treating the compost as a porous medium and employing a standard $k$-$\epsilon$ turbulence model, the researchers developed a 3D simulation validated against field experiments. The model was then used to optimize aeration pipe diameters, demonstrating that increasing diameter from 13 mm to 40 mm significantly improves airflow uniformity and reduces stagnation zones.

Introduction: The Challenge of the "Black Box"

Aerobic composting relies heavily on a consistent oxygen supply to maintain microbial activity. However, the interior of a compost pile is often a "black box." Measuring airflow at the extremely low velocities required for composting—within a dense, corrosive, and high-temperature matrix—is nearly impossible with standard sensors. Historically, this has forced engineers to rely on empirical guesswork for aeration system design.

The industrial-scale aerobic composting reactor used as the basis for the study.

Uneven airflow creates "weak zones" where anaerobic conditions prevail, resulting in greenhouse gas emissions and suboptimal stabilization. This research seeks to provide a theoretical basis for aeration design by creating a high-fidelity CFD model capable of predicting internal fluid dynamics.

Methodology

The study modeled a 1400L in-vessel compost reactor. To manage the complexity of the organic matter, the authors implemented several key technical strategies:

  • Porous Media Approximation: Rather than modeling individual particles, the compost was treated as a homogeneous porous medium. Viscous and inertial resistance coefficients were calculated using the Ergun equation, derived from physical measurements of pig manure and straw mixtures.
  • Geometric Modeling: The reactor geometry, including the main and branch aeration pipes, was discretized using an unstructured mesh to accommodate the complex internal structure.
  • Numerical Methods: The standard $k$-$\epsilon$ model was used for turbulence, while the SIMPLE (Semi-Implicit Method for Pressure Linked Equations) scheme coupled pressure and velocity fields.
  • Validation: The model was validated during the cooling period of the composting process. Air speed measurements were taken at 28–30 specific coordinates within the physical reactor and compared against simulation outputs.
3D schematic of the composting reactor showing the dimensions, internal partitions, and the aeration pipe network.

Key Insights and Results

Model Validation and Homogeneity

The study confirmed that treating compost as a homogeneous porous medium is a valid simplification for engineering purposes. Physical analysis of 36 samples showed that the maximum relative difference in void fraction across the pile was less than 10%. The CFD model itself achieved high accuracy, with an average relative difference of less than 10% between simulated and measured air speeds.

The Impact of Pipe Diameter

A critical finding involved the relationship between pipe diameter and airflow distribution. In the original 13 mm pipe design, air exited the holes at high velocity but failed to circulate effectively near the front of the reactor, creating "vortex zones" and stagnation.

As the pipe diameter was increased to 40 mm, the internal air velocity decreased. This lower momentum allowed the air to exit the pipe holes at more favorable angles, moving directly into the pile rather than "clinging" to the reactor walls. Consequently, the turbulence intensity (a measure of air speed variability) dropped from 3.57 to 1.54 within the pile, indicating a much more uniform oxygen supply.

Conclusion

The developed CFD model successfully provides both qualitative and quantitative analyses of the airflow field in compost piles. By demonstrating that larger aeration pipes can significantly mitigate stagnation zones, this research offers a clear path for optimizing industrial composting systems. Future work will aim to integrate these fluid dynamics with biochemical models of oxygen consumption and heat generation to create a comprehensive "digital twin" of the composting process.

Summary updated

Abstract

Composting is a suitable low-cost strategy to transform animal waste into a stabilized end product, and the airflow field in the pile affects the fermentation states. For piles in the aeration weak zone, anaerobic fermentation may happen as the lack of oxygen. While in practice, due to the extremely low speed and harsh condition, the airflow field was scarcely researched. This study adopted Computational Fluid Dynamics (CFD) to investigate the airflow field in the compost pile. A three-dimensional CFD model was built; the compost pile in this model was simplified as porous media; unstructured mesh was adopted to discretize the geometric model; standard k-ε model and SIMPLE scheme were employed for numerical methods. The CFD model was validated with the field experiment in the cooling period. Then the model was applied to research the airflow field in the pile with increased pipe diameter. Results showed that it was feasible to investigate the airflow field in the pile with CFD. For boundary conditions in the CFD model, treating the compost pile as a homogeneous porous media is reasonable. The CFD model was successfully validated by the field measurement (the average relative difference between the simulated and measured air speed was within 10%). Airflow in the existing compost pile showed nonuniform distribution with stagnation and vortex zones; the turbulence intensities were 3.57 and 1.43 for the airflow in the pile and the reactor, respectively. When pipe diameter increased, the airflow distribution uniformity in the pile was improved significantly. With diameter raising to 0.04 m, the turbulence intensity decreased to 1.54 and 0.42 for the airflow in the pile and the reactor, respectively. The CFD model developed in this research can provide qualitative and quantitative analyses of the airflow field in compost piles, and can be a theoretical basis for the aeration system design. Keywords: CFD, model building, compost, airflow field, pile DOI: 10.25165/j.ijabe.20211404.6087 Citation: Cheng Q Y, Meng H B, Zhou H B, Shen Y J, Cheng H S, Ding J T, et al. Airflow field simulation model building and application for aerobic compost using CFD. Int J Agric & Biol Eng, 2021; 14(4): 245–254.
BibTeX
@article{cheng2021airflow,
  author = {Qiongyi Cheng and Haibo Meng and Haibin Zhou and Yujun Shen and Hongsheng Cheng and Jingtao Ding and Shihao Zhao and Shance Hou},
  title = {{Airflow field simulation model building and application for aerobic compost using CFD}},
  journal = {International Journal of Agricultural and Biological Engineering},
  year = {2021},
  doi = {10.25165/j.ijabe.20211404.6087},
}
Figure