Abstract
Background: To investigate the new cornea biomechanical parameter stress-strain index (SSI) in Chinese healthy people and the factors associated with SSI. Methods: A total of 175 eyes from 175 participants were included in this study. Axial length was measured with the Lenstar LS-900. Pentacam measured curvature of the cornea and anterior chamber volume (ACV). Cornea biomechanical properties assessments were performed by corneal visualization Scheimpflug technology (Corvis ST). Student’s t-test, one-way ANOVA, partial least square linear regression (PLSLR) and linear mixed effects (LME) model were used in the statistical analysis. Results: The mean (±SD) SSI was 1.14 ± 0.22 (range, 0.66–1.78) in all subjects and affected by age significantly after age of 35 (P < 0.05). In LME models, SSI was significantly associated with age (β=0.526, P<0.001), axial length (AL) (β=-0.541, P<0.001), intraocular pressure (IOP) (β=0.326, P<0.001) and steepest radius of anterior corneal curvature (RsF) (β=0.229, P<0.001) but not with ACV, biomechanical corrected intraocular pressure (bIOP), flattest radius of anterior corneal curvature (RfF) or central corneal thickness (CCT) (P>0.05 for each). Conclusions: SSI increased with age after the age of 35. In addition to age, SSI was positively correlated with RsF and IOP, while negatively correlated with AL.
Introduction
Understanding the biomechanical properties of the cornea is critical for diagnosing diseases like keratoconus, planning refractive surgeries such as LASIK, and accurately measuring intraocular pressure (IOP) for glaucoma management. However, the cornea is a complex, viscoelastic tissue, making it difficult to measure "true" material stiffness because traditional measurements are heavily confounded by corneal geometry (thickness and curvature) and internal pressure.
The Stress-Strain Index (SSI) was developed to address this challenge. By utilizing finite element numerical modeling, SSI isolates the material stiffness of the corneal tissue from these confounding factors. While SSI has been mapped in other global populations, this study establishes the first normative data and associated factors for a healthy Chinese population.
Methods
This prospective study included 175 healthy participants (aged 5 to 74 years) at the Tianjin Medical University Eye Hospital. The cohort was divided into seven age groups by ten-year intervals to ensure representative distribution across the lifespan.
Researchers utilized high-end ophthalmic diagnostic tools:
- Corvis ST: A non-contact tonometer using a high-speed Scheimpflug camera to capture the cornea's dynamic response to an air puff and calculate the SSI.
- Lenstar LS-900: Used to measure Axial Length (AL).
- Pentacam: Used to measure corneal curvature and Anterior Chamber Volume (ACV).
Statistical analysis involved Partial Least Square Linear Regression (PLSLR) to filter redundant variables, followed by a Linear Mixed Effects (LME) model to identify the primary drivers of SSI variance.
Results
The study established a baseline for corneal stiffness in the target population. The mean SSI for the cohort was 1.14 ± 0.22, with values ranging from 0.66 to 1.78. Detailed descriptive statistics for all measured parameters are provided in Table 1.
A key finding was the "Age 35" threshold: corneal stiffness remains relatively stable in youth and early adulthood, beginning a significant upward trend only after age 35. This likely reflects cumulative non-enzymatic collagen cross-linking and glycation over time.
Regression analysis revealed that the LME model accounted for a significant portion of SSI variance (Adjusted R² = 0.668). SSI was significantly associated with age, axial length, IOP, and the steepest radius of curvature (RsF). Notably, factors such as gender, ACV, and Central Corneal Thickness (CCT) had no significant effect on SSI, confirming the parameter's independence from corneal thickness.
Discussion and Conclusion
The independence of SSI from CCT is a major clinical advantage, as it allows for the measurement of tissue quality regardless of tissue quantity. Furthermore, the negative correlation between SSI and axial length suggests that the biomechanical weakening associated with myopia affects the cornea in addition to the sclera.
While these findings provide a robust baseline for healthy Chinese eyes, the authors note that these normative values may not apply to pathological cases like keratoconus or post-surgical eyes. Future research should focus on validating SSI for ectatic corneas and exploring the biochemical mechanisms behind the stability of corneal stiffness in populations under age 35. In conclusion, SSI is a valuable, thickness-independent metric that increases with age after 35 and is influenced by axial length and intraocular pressure.
Summary updated