Introduction
Quantifying abdominal obesity—specifically Visceral Adipose Tissue (VAT) and Subcutaneous Adipose Tissue (SAT)—is critical for assessing the risk of metabolic syndromes, cardiovascular diseases, and cancer. While Computed Tomography (CT) is the gold standard for this quantification due to the distinct Hounsfield Unit (HU) range of fat, it involves exposing patients to ionizing radiation. Magnetic Resonance Imaging (MRI) is a safer alternative with superior soft-tissue contrast, but automated segmentation is hindered by a lack of labeled training data, as manual annotation is notoriously labor-intensive.
This paper introduces a cross-modality domain adaptation framework to segment abdominal fat in MRI scans without requiring manually labeled MRI data for training. By translating unlabeled MRI scans into synthetic CT (s-CT) scans, the authors leverage existing models trained on abundant labeled CT data to perform accurate, automated segmentation.
Methods
The proposed pipeline consists of two primary modules that bridge the gap between MRI and CT domains.
Module 1: MRI to CT Domain Adaptation
An unpaired Cycle Generative Adversarial Network (C-GAN) is used to translate MR images into synthetic CT images. To ensure anatomical alignment, the authors designed a custom loss function that enforces spatial registration alongside intensity transformation. Pre-processing includes N-4 Bias correction to remove low-frequency non-uniformity in the MRIs.
Module 2: Fat Segmentation
Two separate U-Net architectures were trained entirely on real, annotated CT scans: a 3-layer network for SAT and a 5-layer network for the more complex VAT. During inference, the s-CT generated from an input MRI is fed into these U-Nets. Because the C-GAN preserves spatial consistency, the resulting masks are directly applicable to the original MRI.
Experimental Setup
- C-GAN Training: Unpaired CT and T1-weighted MR images from 34 patients (NIH dataset).
- U-Net Training: Abdominal CT scans from 131 patients (Mayo Clinic) with ground-truth VAT and SAT labels.
- Evaluation: 320 randomly chosen MR slices were used to test the end-to-end pipeline, evaluated manually by an expert radiologist.
Results
The U-Net models achieved excellent Dice scores on real CT test data: 97.46% for SAT and 94.33% for VAT. The quality of the domain adaptation was a key factor in the pipeline's success.
An expert radiologist rated the synthetic CTs an average of 4.16 out of 5 for structural and textural similarity to real acquired CTs. On the final task of segmenting fat in original MRIs, the pipeline achieved expert ratings of 4.54 out of 5 for SAT and 3.80 out of 5 for VAT, based on False Discovery and False Negative rates.
Discussion and Conclusion
The core innovation of this work is bypassing the data bottleneck in the MRI domain by translating it into the label-rich CT domain. This decoupled architecture allows for independent optimization of modality translation and segmentation tasks.
While the model struggled in regions like the lung base due to intensity overlaps in fat-saturated T1-MRIs, the framework is highly extensible. This core idea—using a C-GAN to bridge the gap between modalities with scarce and abundant labels—can be applied to various biomedical imaging tasks, such as tumor detection or organ segmentation, where ground truth data is difficult to obtain for the target imaging technique.
Summary updated