NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Accuracy of Noise Ceiling Estimators for Brain Scores

Aude Maier, Lucas Gruaz, Martin Schrimpf, Johanni Brea

TL;DR

When comparing artificial neural networks to biological brains, researchers rely on a "noise ceiling" to know the highest score any model could theoretically achieve given noisy brain recordings. This paper puts five standard noise ceiling estimators under a mathematical microscope and reveals a sobering truth: whenever brain responses vary across trials or subjects, our favorite yardsticks systematically underestimate what is possible. That means our AI models might not be as close to "solving" the brain as some leaderboards suggest.

What Problem Does This Paper Address?

In NeuroAI, we test how "brain-like" a deep learning model is by using its internal activations to predict real neural activity (like fMRI voxels or EEG electrodes) while a subject views images or watches a movie. The resulting correlation is called a brain score.

Because biological brains are noisy—due to measurement limits, finite sampling, and fluctuating internal states—no deterministic model can ever achieve a correlation of 1.0. To interpret a raw correlation of, say, 0.4, we divide it by the noise ceiling: the theoretical upper bound of explainable signal in the dataset.

The catch? We don't know the true noise-free brain signal, so we have to estimate the noise ceiling from the noisy data itself. Over the years, the field has invented several ways to do this, either by averaging repeated trials in one person or comparing single trials across different people. Yet, the statistical properties of these estimators were poorly understood, occasionally leading to the bizarre paradox of AI models scoring higher than 100% of the estimated ceiling.

Methods

Instead of proposing yet another ad-hoc estimator, the authors build a unified generative mathematical framework for brain recordings from the ground up. They model any neural recording as a combination of low-dimensional, stimulus-driven latent signals multiplied by trial-specific mixing weights, plus non-reproducible noise.

Figure 1: Signal and trial generation. (a) To mimic the fMRI BOLD response to a continuous stimulus, signals are generated by convolving an event time series with the hemodynamic response function (HRF). (b) To mimic the response to a set of randomly ordered discrete stimuli, signals are generated as i.i.d. Gaussian processes. (c) A trial is generated by multiplying shared and trial-specific signals with trial-specific mixing weights, and adding Gaussian noise. (d) Two generated trials differ by their trial-specific signals and their (potentially) misaligned mixing weights. More details about the generative process are provided in Sec. 3.4.

This formulation cleanly separates experimental setups into two regimes:

  • Homogeneous regime: Repeated trials express latent signals with the exact same mixing weights (an idealized version of showing the same image to the same person multiple times).
  • Heterogeneous regime: Mixing weights vary across trials—such as when "trials" are actually different human subjects with unique brain anatomies, or one subject across different days.

The authors plug this generative model into five standard estimators—two for trial-averaged responses (SHSB and ATV) and three for single-trial responses (LOOC, TTMC, and LOOP)—deriving closed-form analytical expressions for the first four and a geometric characterization for LOOP.

Formulas for standard trial-averaged and single-trial noise ceiling estimators

Datasets

To validate their math where ground truth is known, the authors construct synthetic brain datasets (10×10 voxel grids) simulating both discrete image presentations and continuous fMRI BOLD signals. They then test qualitative alignment against three real-world neuroimaging datasets:

  • THINGS fMRI1: V1 voxel responses from 1 participant viewing 100 repeated images across 12 sessions ($n=12$ trials, $m=1049$ units, $T=100$ stimuli).
  • THINGS EEG2: 17-channel EEG recordings from 1 participant viewing 200 images repeated 80 times across 4 sessions ($n=80$ trials, $m=1700$ channel-time units, $T=200$ stimuli).
  • Sherlock fMRI: V1 and IT cortex recordings from 16 different participants watching a 48-minute episode of BBC's Sherlock ($n=16$ inter-subject trials, $m=623$ voxels, $T=1976$ time points).

Key Insights and Ideas

  • Heterogeneity breaks upper bounds: In the homogeneous regime, standard estimators behave nicely. In the heterogeneous regime (like across-subject movie watching), trial-averaged estimators (ATV, SHSB) underestimate the ceiling by a factor of $\mathcal{O}(1/n)$, while single-trial correlation estimators (LOOC, TTMC) converge to a strict lower limit scaled down by the cosine similarity of subject weights.
  • TTMC is a false upper bound: Researchers often pair LOOC (as a lower bound) with Trial-To-Mean Correlation (TTMC, as an upper bound). The math proves that when subjects differ, TTMC drops below the true noise ceiling—in synthetic tests, failing as an upper bound at just $n \approx 8$ trials.
  • Why models "beat" Brain-Score ceilings: The Leave-One-Out Prediction (LOOP) method fits a linear model across subjects and extrapolates to infinite subjects using an exponential curve. While LOOP can theoretically reach the true ceiling, finite recording lengths ($T$) cause overfitting as predictors grow, dragging scores down. Extrapolating this dragged-down curve underestimates the ceiling, explaining why modern LLMs and vision models frequently appear to exceed 100%.
  • The weak-signal upward bias: When recording durations ($T$) are short and a brain unit has very weak signal, thresholding negative variance estimates at zero creates an upward finite-sample bias of order $T^{-1/4}$ in ATV and SHSB.

Key Results

Across both synthetic simulations and real fMRI/EEG data, empirical noise ceiling curves closely track the authors' closed-form theoretical predictions.

  • In homogeneous settings (mimicking THINGS fMRI1 and EEG2), ATV and SHSB nearly overlap and accurately recover the trial-averaged ceiling, while LOOC and TTMC sandwich the single-trial ceiling from below and above.
  • In heterogeneous settings (Sherlock V1 and IT), LOOP outperforms LOOC on real brain data by pooling correlated neighboring voxels, yet synthetic ground-truth comparisons confirm it still saturates well below the true single-trial ceiling.
  • As a concrete fix, the authors recommend ATV for trial-averaged evaluations, and advise reporting intervals—from the raw score up to the score normalized by the best cross-validated lower bound—whenever heterogeneity leaves us without a true upper bound.

Limitations and Future Work

The authors define "signal" as anything reproducible within a trial, which includes idiosyncratic subject responses; if a researcher only cares about brain activity shared universally across humanity, the target ceiling would be lower (though downward estimator biases from anatomical misalignment would persist). Furthermore, LOOP lacks a full closed-form expression for finite sample sizes, and empirical tests were limited to visual/audiovisual fMRI and EEG—leaving invasive electrophysiology, MEG, and language or motor benchmarks for future exploration. Finally, quantifying exactly how much heterogeneity creeps into single-subject repeats across sessions (due to familiarity or electrode drift) remains an open question.

Summary updated

BibTeX
@inproceedings{maier2026accuracy,
  author = {Aude Maier and Lucas Gruaz and Martin Schrimpf and Johanni Brea},
  title = {{Accuracy of Noise Ceiling Estimators for Brain Scores}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=AWvO8s9XuP},
}

Loading related content...

Figure