Accelerating Quantitative MRI using Subspace Multiscale Energy Model (SS-MuSE)

Yan Chen, Jyothi Rikhab Chand, Steven Kecskemeti, James H. Holmes, Mathews Jacob · DOI

Abstract: Multi-contrast MRI methods acquire multiple images with different contrast weightings, which are used for the differentiation of the tissue types or quantitative mapping. However, the scan time needed to acquire multiple contrasts is prohibitively long for 3D acquisition schemes, which can offer isotropic image resolution. While deep learning-based methods have been extensively used to accelerate 2D and 2D + time problems, the high memory demand, computation time, and need for large training data sets make them challenging for large-scale volumes. To address these challenges, we generalize the plug-and-play multi-scale energy-based model (MuSE) to a regularized subspace recovery setting, where we jointly regularize the 3D multi-contrast spatial factors in a subspace formulation. The explicit energy-based formulation allows us to use variable splitting optimization methods for computationally efficient recovery.

Introduction

Quantitative MRI (qMRI) is considered a "holy grail" of medical imaging because it provides objective measurements of tissue properties, such as $T_1$ relaxation times, rather than qualitative "weighted" images. However, capturing the multiple image contrasts required for these calculations is notoriously slow, especially for high-resolution 3D volumes.

While deep learning has successfully accelerated 2D imaging, 3D+time (4D) data presents a significant "memory wall." Standard unrolled neural networks require massive GPU memory and large training datasets that are often unavailable for 3D sequences. Recent self-supervised methods, like the Deep Factor Model (DFM), avoid the need for massive datasets but are computationally expensive, often requiring over 8 hours to reconstruct a single patient scan.

Methods

The authors introduce SS-MuSE (Subspace Multiscale Energy Model), which utilizes a two-pronged strategy to accelerate reconstruction:

  1. Subspace Modeling: Instead of reconstructing every time-point image, the data is factorized into a small set of temporal basis functions (derived from Bloch equation simulations) and their corresponding spatial maps. This drastically reduces the number of unknowns in the optimization problem.
  2. MuSE Regularization: A "Plug-and-Play" (PnP) multiscale energy-based model is used as a prior. Unlike standard black-box denoisers, MuSE models the underlying probability distribution of images, allowing for sharper edges and superior denoising.
  3. The 2D-to-4D Bridge: To avoid the memory cost of 3D/4D convolutions, the authors apply a 2D MuSE model to slices of the 3D volume along multiple orientations ($x-z$ and $y-z$ planes). This captures 3D spatial correlations while maintaining the efficiency of 2D training.
The SS-MuSE framework architecture.

The optimization is handled via variable splitting, alternating between a data consistency step and a denoising step using the MuSE prior. The model was trained on 930 complex 2D slices from healthy volunteers and tested on a 3D radial inversion recovery sequence (MPnRAGE).

Key Results

SS-MuSE was compared against standard subspace methods and the state-of-the-art Deep Factor Model (DFM). Key findings include:

  • Reconstruction Speed: SS-MuSE reduced the runtime from 8 hours (DFM) to 3 hours, marking a significant step toward clinical feasibility.
  • Quantitative Accuracy: SS-MuSE achieved a PSNR of 25.0 dB for $T_1$ maps, outperforming DFM (23.7 dB) and classical wavelet-based subspace methods (19.7 dB).
  • Visual Fidelity: Qualitative results showed that SS-MuSE maintained sharper edges and fewer aliasing artifacts, particularly at short inversion times where the signal is weakest.
Quantitative comparison of T1 maps and error metrics.

Conclusion

SS-MuSE provides a robust framework for accelerating 3D quantitative MRI by combining physics-informed subspace modeling with efficient multiscale energy-based priors. By regularizing 3D volumes using multi-planar 2D priors, the method bypasses the memory constraints of 3D deep learning while delivering superior image quality and faster reconstruction. Future work will focus on further optimizing the NUFFT operations to reach near real-time performance and validating the model on clinical cohorts with diverse pathologies.

Summary updated

BibTeX
@misc{chen2025accelerating,
  author = {Yan Chen and Jyothi Rikhab Chand and Steven Kecskemeti and James H. Holmes and Mathews Jacob},
  title = {{Accelerating Quantitative MRI using Subspace Multiscale Energy Model (SS-MuSE)}},
  year = {2025},
  eprint = {2502.10580},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2502.10580},
}
Figure