AbdomenCT-1K: Is Abdominal Organ Segmentation a Solved Problem?

Jun Ma, Yao Zhang, Song Gu, Cheng Zhu, Cheng Ge, Yichi Zhang, Xingle An, Congcong Wang, Qiyuan Wang, Xin Liu, Shucheng Cao, Qi Zhang, Shangqing Liu, Yunpeng Wang, Yuhui Li, Jian He, Xiaoping Yang · OpenReview

Abstract

Deep learning models for abdominal organ segmentation frequently achieve human-level performance on standard benchmarks. This paper questions whether the problem is truly "solved" by introducing AbdomenCT-1K, a massive and diverse dataset of over 1,000 CT scans. Our findings reveal significant generalization gaps when models encounter out-of-distribution clinical data, such as unseen diseases or varying contrast phases. To address these challenges, we propose four new benchmarks covering diverse learning paradigms: fully supervised, semi-supervised, weakly supervised, and continual learning.

Introduction

While state-of-the-art (SOTA) models excel on homogeneous public datasets, they often struggle with the "messy reality" of clinical practice. Existing benchmarks are typically limited to single-center data, specific scanner vendors, or healthy organs. This lack of diversity masks failures in generalizing to different CT contrast phases or severe, heterogeneous lesions. Furthermore, the reliance on the Dice Similarity Coefficient (DSC) often overlooks critical boundary inaccuracies essential for surgical planning.

Overview of the AbdomenCT-1K dataset and the four established benchmarks.

To bridge this gap, we present AbdomenCT-1K, a large-scale dataset aggregated from 12 medical centers, featuring multi-phase, multi-vendor, and multi-disease cases. We manually annotated missing organs in existing datasets (LiTS, KiTS, MSD, NIH) to provide consistent ground truth for the liver, kidney, spleen, and pancreas across 1,112 scans.

Methods and Benchmarks

We established four distinct benchmarks using the nnU-Net architecture as a baseline to evaluate different learning scenarios:

  1. Fully Supervised Learning: Focuses on multi-organ segmentation with a specific emphasis on challenging, out-of-distribution test cases (e.g., tumors, noise).
  2. Semi-Supervised Learning: Employs a teacher-student framework with pseudo-labeling to leverage a small labeled set (e.g., 41 cases) alongside a large unlabeled pool (800 cases).
  3. Weakly Supervised Learning: Trains models using sparse, slice-level annotations (5% to 30% of slices) to reduce annotation effort.
  4. Continual Learning: Evaluates the model's ability to learn new organ segmentations sequentially without "catastrophic forgetting" of previously learned tasks.

Key Insights and Results

Our large-scale study yielded several critical insights into the current state of abdominal segmentation:

The Generalization Gap

Models trained on specific distributions show significant performance drops when tested on different phases. For instance, a kidney model trained on arterial phase data (KiTS) saw a 15% drop in DSC when applied to portal phase data (LiTS).

Boundary Accuracy vs. Region Overlap

A major finding is that the standard DSC metric can be misleading. A model may achieve a high DSC (>95%) while failing significantly in boundary precision, as measured by the Normalized Surface Dice (NSD).

Comparison of Dice Similarity Coefficient (DSC) and Normalized Surface Dice (NSD) in evaluating segmentation quality.

Benchmark Performance

  • Pancreas Complexity: The pancreas remains the most challenging organ to segment due to its complex morphology, consistently yielding the lowest scores across all benchmarks.
  • Semi-Supervised Success: We found that using only 41 labeled cases with 800 unlabeled cases achieved a DSC of 91.5%, nearly matching the performance of a fully supervised model trained on over 800 labeled cases.
  • Weakly Supervised Potential: Annotating just 15% of slices allowed the model to reach over 85% DSC for liver segmentation, though post-processing with Conditional Random Fields (CRF) did not provide the expected improvements.

Conclusion

Abdominal organ segmentation is far from a solved problem. The AbdomenCT-1K dataset and its associated benchmarks highlight the need for models that are robust to clinical variation and boundary-sensitive. Future work should focus on improving pancreas segmentation, refining weakly supervised techniques, and developing more effective strategies for continual learning in the medical domain.

Summary updated

BibTeX
@article{ma2021abdomenct,
  author = {Jun Ma and Yao Zhang and Song Gu and Cheng Zhu and Cheng Ge and Yichi Zhang and Xingle An and Congcong Wang and Qiyuan Wang and Xin Liu and Shucheng Cao and Qi Zhang and Shangqing Liu and Yunpeng Wang and Yuhui Li and Jian He and Xiaoping Yang},
  title = {{AbdomenCT-1K: Is Abdominal Organ Segmentation a Solved Problem?}},
  journal = {IEEE Transactions on Pattern Analysis and Machine Intelligence},
  year = {2021},
  doi = {10.1109/tpami.2021.3100536},
}
Figure