Abstract A simulation method based on the liquid crystal response and the human visual system is suitable to characterize motion blur for LCDs but not other display types. We propose a more straightforward and widely applicable method to quantify motion blur based on the width of the moving object. We thus compare various types of displays objectively. A perceptual experiment was conducted to validate the proposed method. We test varying motion velocities for nine commercial displays. We compare the three motion blur evaluation methods (simulation, human perception, and our method) using z-scores. Our comparisons indicate that our method accurately characterizes motion blur for various display types.
Introduction: The Challenge of Universal Motion Blur Measurement
Motion blur—the smearing or "ghosting" effect observed when objects move across a screen—is a significant factor in display quality. While well-understood in the context of Liquid Crystal Displays (LCDs), measuring it objectively across diverse hardware remains a challenge.
Traditional metrics like Blurred Edge Time (BET) or Motion Picture Response Time (MPRT) are tailored for the "sample-and-hold" nature of LCDs. However, these models often fail when applied to "impulse" displays, such as Cathode Ray Tubes (CRTs) or Plasma Display Panels (PDPs), which emit light in short bursts.
As shown in the figure above, the integration of light on the retina differs fundamentally between display types. Furthermore, many standard metrics are time-relative and do not fully account for how blur scales with the actual velocity of the moving object. The industry has lacked a unified, objective way to compare a high-end gaming monitor to a plasma TV or a medical-grade CRT.
The Moving Block Width (MBW) Method
To address these limitations, the researchers propose the Moving Block Width (MBW) method. Instead of focusing solely on the transition at the edge of a moving object (the 10% to 90% luminance curve), they measure the width of the entire moving block as perceived by a detector.
The core of the method involves:
- Defining $\Delta MBW$: This is the difference between the width of the block when moving ($MBW_1$) and its width when stationary ($MBW_0$).
- Experimental Setup: Using a programmable signal generator and a high-speed Light Measurement Detector (LMD), they record the luminance of the center of the screen as a white block moves across it at various velocities (measured in Pixels Per Frame, or PPF).
- Luminance Profile Analysis: By plotting $\Delta MBW$ against velocity, they use the slope of the resulting line as a comprehensive performance metric.
A smaller change in width as speed increases indicates better motion handling. This approach is robust because it doesn't require complex mathematical convolutions to filter out backlight noise; the raw luminance data from the moving block is naturally more stable.
Experimental Evaluation and Datasets
The study evaluated a "physical dataset" of nine commercial displays:
- CRT: One 19" unit (the "gold standard" for motion).
- PDP: Two Plasma displays (one 60", one 43" 3D display).
- LCD: Six units featuring various technologies, including TN and IPS panels, CCFL vs. LED backlighting, and "backlight blinking" features designed to reduce blur.
Additionally, subjective scores were collected from 8 participants who ranked motion clarity on a 7-point Likert scale to validate the objective results.
Key Insights and Results
- The CRT Paragon: The CRT display showed a unique "negative slope." As scroll speed increased, the perceived width actually decreased slightly due to the scanning nature of the electron beam. This confirms why CRTs are still prized for motion clarity—they represent the "ideal" impulse display.
- Simulation Limits: Standard simulation algorithms based on Liquid Crystal Response Curves (LCRC) are essentially "LCD-only" tools and are ineffective for CRTs and PDPs.
- Velocity Matters: Motion blur is a function of speed. By using the slope of the $\Delta MBW$-speed plot, the researchers captured a more "holistic" view of display performance than a single-point measurement.
- Universal Benchmark: The researchers used z-scores to normalize data from simulation, human perception, and the MBW method. The MBW z-scores aligned closely with human judgment across all nine displays, successfully ranking them from best (CRT) to worst (standard LCD).
- Backlight Blinking Works: The data clearly showed that LCDs with backlight blinking performed significantly better than those without, approaching the performance of Plasma displays.
Limitations and Future Work
While the MBW method is straightforward and effective, several areas remain for expansion. Real-world motion involves Gray-to-Gray (GtG) transitions rather than just black-to-white. Future research should also investigate how resolution, refresh rates (e.g., 120Hz vs 60Hz), and pattern complexity (shape and size of the moving object) influence the MBW metric.
Summary updated