A smart primary side current sensing strategy for single stage isolated PFC controller

Jiajun Hu, Houpeng Chen, Qian Wang, Xi Li 0012, Xi Fan, Xiaoyun Li, Yu Lei, Zhitang Song

Abstract

A novel primary side current sensing strategy is presented in this paper, which is especially suitable for the primary side controlled high power factor single-stage flyback LED controller. In order to avoid the constant-current regulation accuracy error caused by electromagnetic interference (EMI) issue, the proposed current sensing technique utilizes the switched-capacitor interleaved sample and hold circuit to obtain the middle point of the primary side current sensing period. The single-stage LED driver utilizing the proposed current sensing scheme has been implemented in CZ6H 0.35 µm standard CMOS process; simulation results show that load regulation and line regulation accuracy can be improved greatly.

Introduction

High-brightness LEDs require precise constant current to ensure longevity and consistent light output. Single-stage primary-side controlled flyback converters are a popular choice for these drivers because they offer electrical isolation and a small footprint. However, these systems face a major hurdle: Electromagnetic Interference (EMI).

In traditional designs, the controller senses the "peak" inductor current at the exact moment the MOSFET switches off. This switching event creates significant voltage spikes and dips (noise) at the sensing node. To mitigate this, engineers often add resistors ($R_G$) to slow down the switching, but this introduces propagation delays that vary with input voltage, leading to poor line regulation—where the output current drifts as the AC wall voltage changes.

The Middle-Point Current Sensing (MPCS) Strategy

To address the noise issues inherent in peak sensing, this paper proposes a Middle-Point Current Sensing (MPCS) scheme. Because the inductor current in a flyback converter operating in Discontinuous Conduction Mode (DCM) rises linearly, the current at the exact midpoint of the turn-on period ($T_{ON}/2$) is exactly half of the peak current.

System architecture (a) and the EMI noise coupling path (b) illustrating the voltage dip at the sensing node.

By moving the sensing point to the middle of the $T_{ON}$ period, the system achieves physical temporal isolation from switching noise. The sample switch is already turned off by the time the EMI-inducing turn-off event occurs, ensuring a clean measurement.

Technical Implementation

The MPCS scheme relies on two key technical components:

  1. Half Turn-On Period Generator: A novel circuit using an interleaved switched-capacitor architecture. It uses three matched capacitors to measure the duration of the previous switching cycle's $T_{ON}$ and generate a trigger pulse at exactly the halfway mark of the current cycle. Since switching frequency is much higher than AC line frequency, the $T_{ON}$ duration changes minimally between cycles, allowing for accurate predictive timing.
  2. Sample and Hold (S/H) Circuit: A switch ($M_S$) and hold capacitor ($C_{HOLD}$) capture the voltage at the midpoint.

Results and Discussion

The design was implemented using a 0.35 µm standard CMOS process, occupying a total area of 1.22 $mm^2$. Post-layout SPICE simulations and theoretical modeling were used to verify the strategy against traditional peak-sensing methods.

Key performance metrics include:

  • Error Reduction: In a standard system (85V to 285V AC input), conventional peak sensing error ranged from 11.6% to 33.1%. With the MPCS scheme, this error was reduced to between 3.5% and 6.7%.
  • Line Regulation: The proposed controller maintained LED current accuracy within 3% across the entire universal input voltage range.
  • Robustness: Unlike traditional methods, MPCS accuracy is significantly less sensitive to the propagation delays caused by gate resistors, making the design easier to stabilize against EMI.

Conclusion

The proposed MPCS strategy effectively bypasses the EMI challenges of primary-side sensing by shifting the measurement window away from noisy switching edges. By utilizing the linear nature of inductor current in DCM, the system provides a simple, computationally inexpensive, and highly accurate solution for universal line supply LED drivers. Future work may involve physical fabrication to further validate these simulation results against real-world parasitic effects.

Summary updated

Abstract

A novel primary side current sensing strategy is presented in this paper, which is especially suitable for the primary side controlled high power factor single-stage flyback LED controller. In order to avoid the constant-current regulation accuracy error caused by electromagnetic interference (EMI) issue, the proposed current sensing technique utilizes the switched-capacitor interleaved sample and hold circuit to obtain the middle point of the primary side current sensing period. The single-stage LED driver utilizing the proposed current sensing scheme has been implemented in CZ6H 0.35 um standard CMOS process, simulation results show that load regulation and line regulation accuracy can be improved greatly.
BibTeX
@article{hu2015smart,
  author = {Jiajun Hu and Houpeng Chen and Qian Wang and Xi Li and Xi Fan and Xiaoyun Li and Yu Lei and Zhitang Song},
  title = {{A smart primary side current sensing strategy for single stage isolated PFC controller}},
  journal = {IEICE Electron. Express},
  year = {2015},
  doi = {10.1587/elex.12.20150901},
}
Figure