Abstract: A PARAMETRIC STUDY OF FRICTION PENDULUM SYSTEMS FOR BASE-ISOLATED BUILDINGS: INSIGHTS INTO PERFORMANCE ACROSS SEISMIC INTENSITIES - 10th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering - 15-18 June 2025, Rhodes Island, Greece

Introduction

Base isolation is a premier strategy for protecting critical infrastructure, such as schools and hospitals, from seismic events. Friction Pendulum Systems (FPS) are widely used for this purpose, dissipating energy through friction as the building slides on curved surfaces. However, engineers face significant challenges due to parameter uncertainty—such as variations in friction coefficients due to manufacturing or aging—and the "activation threshold." If ground motion is insufficient to overcome static friction, the system remains rigid, potentially compromising structural health monitoring (SHM) efforts. This study quantifies how these uncertainties impact structural response across varying seismic intensities.

Methodology

The research utilizes a high-fidelity Finite Element (FE) model of the G. Marconi school in Foligno, Italy. This real-world reinforced concrete building features four floors above ground and an isolation layer comprising 38 FPS isolators.

Figure 2: 3D Finite Element model (a) and plan view of the isolator layout (b) for the G. Marconi school, identifying four types of Friction Pendulum (FP) units.

The parametric study involved 100 combinations of three variables: high-speed friction ($\mu_{fast}$), the rate parameter ($rp$), and the initial stiffness coefficient ($a_K$). Simulations were performed in SAP2000 using an iterative computational procedure to converge on effective stiffness ($K_{eff}$), which is displacement-dependent. The model was tested against seven artificial "design-level" accelerograms and four real, lower-intensity earthquake records from the ITACA database.

Key Insights and Results

The Activation Gap

A critical finding is the "activation gap" during low-intensity events. In simulations using real-world records from the 2016-2017 Central Italy sequence, the seismic intensity was insufficient to trigger sliding. The isolators remained in their elastic phase with deformations limited to approximately 1 mm. This lack of activation hinders SHM, as sensors cannot detect degradation in the friction surfaces without movement.

Parameter Sensitivity and Linearity

Analysis revealed that $\mu_{fast}$ and $a_K$ are the dominant parameters affecting performance, while the rate parameter ($rp$) has a marginal impact. Interestingly, despite the inherent nonlinearity of FPS, the study found a nearly linear relationship between the friction coefficient and effective stiffness under design-level inputs.

Figure 4: Effective stiffness ($K_{eff}$) as a function of the high-speed friction coefficient ($\mu_{fast}$) for different isolator types, demonstrating a strong linear correlation.

Performance Trade-offs

In high-intensity scenarios, increasing friction from 0.04 to 0.12 reduced relative displacement by about 5 cm but increased the base shear transmitted to the structure. Higher-capacity isolators (e.g., FP3) demonstrated steeper hysteresis loops and superior energy dissipation compared to lower-capacity units (e.g., FP2).

Conclusion

The study highlights that while FPS isolators perform predictably during major seismic events, their behavior during low-to-moderate tremors is essentially rigid. This "frozen" state poses challenges for validating system health over time. Future work should focus on interpreting data from these low-intensity events and refining initial stiffness models to better account for the wide range of empirical values found in current literature.