Abstract: Presented at the 9th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering (COMPDYN 2023), this research explores a novel passive vibration control strategy for multi-storey buildings. By utilizing a geometrically nonlinear device to introduce negative stiffness at the top floor, the study demonstrates significant reductions in seismic response, effectively turning the top storey into a large-scale resonator.
Introduction
Traditional seismic protection usually falls into two categories: Base Isolation, which is highly effective but expensive and difficult to retrofit, and Tuned Mass Dampers (TMDs), which require adding a massive secondary weight to the top of a building.
The challenge is finding a passive, low-cost, and low-complexity solution that can be easily retrofitted to existing buildings. The authors address this by investigating "partial mass isolation." Instead of adding a new mass, the properties of the existing top floor are modified so it acts as a damper for the rest of the building. To achieve this without changing the floor's weight, the floor's stiffness must be significantly reduced—specifically, by introducing negative stiffness to counteract the natural positive stiffness of the structural columns.
The NegSV Mechanism
The core of the paper is the NegSV device, a passive vibration control mechanism that uses geometric nonlinearity to create negative stiffness. It consists of a triangular arch assembly of springs. As the device deforms under lateral load, it reaches a point where the "restoring" force actually pushes in the same direction as the displacement, providing the negative stiffness component.
System Dynamics and Tuning
When this negative stiffness device is connected in parallel with the standard (positive) linear stiffness of the building's columns ($k$), the total stiffness of the top floor drops significantly. This allows the top floor to act as a resonator tuned to the building's fundamental frequency without adding extra mass.
As shown in the equilibrium path, the nonlinear force ($F_{nl}$) partially cancels out the linear restoring force ($F_l$), resulting in a "softer" total force-displacement curve ($F_{tot}$). This surgical application of negative stiffness is the key to tuning the system for maximum energy absorption.
Methodology and Results
The research team evaluated the device using a theoretical 4-storey concrete frame building. They employed both high-fidelity 3D Finite Element (FE) models and simplified Lumped Mass models. To ensure robustness, they performed Monte Carlo simulations with 10,000 synthetic ground motions calibrated to Eurocode 8 (EC8) spectra.
The results show that the NegSV device is highly effective at protecting the critical lower portions of the structure:
- Acceleration Reduction: Peak accelerations at the first floor were reduced by 31.4%.
- Drift Reduction: Inter-storey drift at the base—a primary indicator of structural damage—was reduced by 24.9%.
- Probability of Failure: The probability of the base drift exceeding the 2% safety limit dropped from 3.2% to 2.3%.
Discussion and Trade-offs
The primary trade-off for protecting the building's base is "sacrificial displacement" at the top. The top floor's drift increased by 66.2% as it acted as an energy sink. However, the peak drift remained under 1%, well within the safety limits prescribed by international codes.
Because the NegSV device uses cables and springs that can be fitted into an existing storey with moderate interference, it represents a viable path for upgrading older buildings. Future work will focus on adding specific damping elements to further control top-floor drifts and moving toward experimental shake-table validation.
Summary updated