A Novel Compressed Sensing Scheme for Photoacoustic Tomography

Michael Sandbichler, Felix Krahmer, Thomas Berer, Peter Burgholzer, Markus Haltmeier

Abstract

Speeding up the data acquisition is one of the central aims to advance tomographic imaging. On the one hand, this reduces motion artifacts due to undesired movements, and on the other hand this decreases the examination time for the patient. In this article, we propose a new scheme for speeding up the data collection process in photoacoustic tomography. Our proposal is based on compressed sensing and reduces acquisition time and system costs while maintaining image quality. As measurement data we use random combinations of pressure values that we use to recover a complete set of pressure data prior to the actual image reconstruction. We obtain theoretical recovery guarantees for our compressed sensing scheme and support the theory by reconstruction results on simulated data as well as on experimental data.

Introduction

Photoacoustic Tomography (PAT) is a powerful hybrid imaging modality that leverages the high contrast of optical imaging and the deep penetration and high resolution of ultrasound. The process begins with short laser pulses that illuminate biological tissue. Chromophores in the tissue absorb this energy, causing a rapid thermoelastic expansion that generates ultrasonic waves. These waves propagate to the surface, where they are captured by an array of detectors to reconstruct an image of the internal structure.

The fundamental process of Photoacoustic Tomography: from optical illumination to boundary measurements.

The Speed-Cost Bottleneck in PAT

Despite its potential, PAT faces a significant "speed vs. cost" bottleneck. High-resolution 3D imaging requires a large number of detectors. Digitizing every detector signal simultaneously necessitates a massive array of Analog-to-Digital Converters (ADCs), which significantly increases system costs. Conversely, using a smaller number of ADCs and multiplexing them across sensors increases the data acquisition time, making the system prone to motion artifacts from patient movement.

Standard Compressed Sensing (CS) offers a potential solution by allowing for the reconstruction of signals from fewer samples. However, applying CS to PAT is challenging because raw acoustic pressure data is not naturally sparse—a prerequisite for traditional CS techniques. This research addresses this challenge by introducing a physics-informed sparsifying transform and a hardware-efficient signal mixing scheme.

Proposed Methodology

The authors propose a two-stage solution that combines hardware-level signal summation with a novel mathematical recovery framework.

Hardware-Level Random Summation

Instead of digitizing each sensor individually, the proposed system sums signals from a random subset of sensors into a single ADC. This process is modeled using "lossless expander graphs," which are binary matrices where each sensor contributes to a fixed number of measurements. This approach allows for $m$ compressed measurements to represent $N$ total sensor positions, where $m \ll N$, drastically reducing the number of required ADCs.

A bipartite graph illustrating the mapping of N sensor signals to m compressed measurements via random summation.

The Sparsifying Transform and Recovery

To recover the original high-resolution signals from the compressed data, the signals must be represented in a domain where they are sparse. The researchers identified that while raw pressure signals are dense, a specific temporal transform—utilizing the Hilbert transform and radial derivatives—renders the data highly sparse in its spatial (angular) component.

By applying this transform, the recovery problem becomes a standard CS optimization task. The authors utilized both $\ell_1$-minimization and Total Variation (TV) minimization to solve the underdetermined system. Their findings indicated that TV minimization was particularly effective at preserving the sharp edges of the imaged objects and reducing reconstruction artifacts.

Experimental Validation and Results

The scheme was validated using both simulated phantoms and real-world experimental data. In the experimental setup, a 120 $\mu$m diameter bristle tied into a knot was measured at 121 positions.

Key results include:

  • 50% Data Reduction: High-quality images were successfully reconstructed using only 60 compressed measurements, effectively halving the required data.
  • Artifact Suppression: The CS approach showed significantly fewer artifacts compared to "naive" under-sampling (simply using fewer sensors without mixing).
  • Improved Signal-to-Noise Ratio (SNR): The summation of multiple sensor signals provides a form of coherent averaging, which naturally boosts the SNR in the presence of noise.

Conclusion

This novel compressed sensing scheme provides a robust framework for reducing the hardware complexity and acquisition time of Photoacoustic Tomography. By shifting the burden from expensive electronics to clever mathematical transforms and simple signal mixing, this approach paves the way for faster, more cost-effective clinical PAT systems. Future work will focus on adapting these transforms for more complex, heterogeneous biological tissues and refining the hardware implementation of the random matrix switches.

Summary updated

Abstract

Speeding up the data acquisition is one of the central aims to advance tomographic imaging. On the one hand, this reduces motion artifacts due to undesired movements, and on the other hand this decreases the examination time for the patient. In this article, we propose a new scheme for speeding up the data collection process in photoacoustic tomography. Our proposal is based on compressed sensing and reduces acquisition time and system costs while maintaining image quality. As measurement data we use random combinations of pressure values that we use to recover a complete set of pressure data prior to the actual image reconstruction. We obtain theoretical recovery guarantees for our compressed sensing scheme and support the theory by reconstruction results on simulated data as well as on experimental data.
BibTeX
@article{sandbichler2015novel,
  author = {Michael Sandbichler and Felix Krahmer and Thomas Berer and Peter Burgholzer and Markus Haltmeier},
  title = {{A Novel Compressed Sensing Scheme for Photoacoustic Tomography}},
  journal = {SIAM J. Appl. Math.},
  year = {2015},
  url = {https://openreview.net/forum?id=3xVCiKr53Q},
}
Figure