A Mosquito Pick-and-Place System for PfSPZ-Based Malaria Vaccine Production

Henry Phalen, Prasad Vagdargi, Mariah L. Schrum, Sumana Chakravarty, Amanda Canezin, Michael Pozin, Suat Coemert, Iulian Iordachita, Stephen L. Hoffman, Gregory S. Chirikjian, Russell H. Taylor

TL;DR

Researchers have developed a robotic pick-and-place system to automate the tedious manual dissection of mosquitoes required for malaria vaccine production. By combining a custom micro-gripper, a specialized dissection fixture, and deep-learning-based computer vision, the system achieved 100% grasping accuracy and 90% successful placement, paving the way for mass-produced malaria vaccines.

What Problem Does This Paper Address?

Malaria remains a massive global health crisis, but a promising vaccine exists: the Sanaria® PfSPZ Vaccine. This vaccine is made from live sporozoites (SPZ) extracted from the salivary glands of Anopheles mosquitoes.

The bottleneck? Extraction. Currently, highly trained technicians must manually decapitate and "squeeze" mosquitoes under a microscope—one at a time. It takes months to train a technician, and even then, they can only process about 4–5 mosquitoes per minute. To produce vaccines at a global scale, we need to process millions of mosquitoes, making this manual labor the primary obstacle to eradication.

Methods

The authors tackled this by first "deskilling" the manual process and then automating its most difficult step: the pick-and-place.

  1. The 3MDF Fixture: They created the Manual Mosquito Micro-dissection Fixture (3MDF). Instead of using a needle like a knife, mosquitoes are dragged into slots where a pair of notched, spring-loaded blades (similar to hair clippers) can decapitate 20 mosquitoes at once.
  2. The Robot: They integrated a 4-DOF linear stage robot with a custom micro-gripper. Interestingly, the gripper tooltip was adapted from Alcon Grieshaber retinal surgical forceps—tools designed for human eye surgery—to handle the delicate 0.1mm diameter mosquito proboscis (the "nose").
  3. Computer Vision Stack: The system uses two cameras. An overhead camera provides coarse localization. Once the robot is close, an onboard camera uses a SegNet deep learning architecture (with a VGG-16 backbone) to segment the mosquito into three parts: proboscis, head, and body. This allows the robot to calculate the exact "grasp point" on the proboscis and the "placement offset" for the neck.

Datasets

The authors created a custom dataset to train their segmentation network:

  • Mosquito Part Dataset: 185 high-resolution images (1600x1200 px) of mosquitoes in various contorted and "non-standard" orientations.
  • Annotations: Each image was manually pixel-labeled for three classes: proboscis, head, and body.
  • Augmentation: To compensate for the small dataset size, they used rigorous data augmentation (rotation, translation, and scaling) during training.

Key Insights and Ideas

  • The Proboscis as a Handle: The authors realized the proboscis is the only viable "handle." Grabbing the body risks crushing the salivary glands or contaminating the sample with "exudate" (mosquito guts).
  • Deskilling Before Automating: By first designing the manual 3MDF fixture, the researchers created a structured environment that made automation feasible. The fixture turned a complex 3D "surgery" into a 2D alignment task.
  • Adaptive Automation: Mosquitoes are highly deformable and non-uniform. A hard-coded robot path would fail. The "aha moment" was using the onboard camera to calculate a real-time offset after the grasp to account for exactly where on the 2mm-long proboscis the gripper landed.
  • The Fulcrum Effect: A surprising physical finding was that failures often occurred because the mosquito body acted as a lever. If the neck wasn't perfectly aligned, the body would hit the blade and flip over like a see-saw rather than sliding into the notch.

Key Results

  • Manual Throughput: The 3MDF fixture alone increased manual throughput to 470–600 mosquitoes per hour, a significant jump from the ~290 Mdph (mosquitoes dissected per hour) achieved by traditional manual methods. It also reduced training time from 16 weeks to just a few sessions.
  • Robotic Accuracy: In a pilot test of 50 mosquitoes, the robot achieved:
  • 100% Grasping Accuracy: Every mosquito was successfully picked up by its proboscis.
  • 90% Placement Accuracy: 45 out of 50 were placed correctly in the blades for successful decapitation.
  • Speed: The robotic cycle took 7.5 seconds, suggesting a theoretical throughput of ~470 Mdph, with potential to reach 700 Mdph with further optimization.

Limitations and Future Work

While the pick-and-place is a success, the "squeeze and collect" phase of the dissection is still manual in this study. The authors also noted that 2D vision can be deceptive; because the robot holds the proboscis at an angle, the "foreshortening" in the top-down view can lead to slight placement errors.

Future iterations will focus on:

  • 3D Vision: Incorporating side-view cameras to better estimate the 3D pose of the mosquito.
  • Full Automation: Integrating the "vortex" staging area (which feeds mosquitoes to the robot) and the automated squeezer to create a true end-to-end "vaccine factory."
  • Mechanical Tweaks: Redesigning the blade notches to be more "self-centering" to tolerate small robotic misalignments.

Summary updated

Abstract

The treatment of malaria is a global health challenge that stands to benefit from the widespread introduction of a vaccine for the disease. A method has been developed to create a live organism vaccine using the sporozoites (SPZ) of the parasite Plasmodium falciparum (Pf), which are concentrated in the salivary glands of infected mosquitoes. Current manual dissection methods to obtain these PfSPZ are not optimally efficient for large-scale vaccine production. We propose an improved dissection procedure and a mechanical fixture that increases the rate of mosquito dissection and helps to deskill this stage of the production process. We further demonstrate the automation of a key step in this production process, the picking and placing of mosquitoes from a staging apparatus into a dissection assembly. This unit test of a robotic mosquito pick-and-place system is performed using a custom-designed microgripper attached to a four-degree-of-freedom (4-DOF) robot under the guidance of a computer vision system. Mosquitoes are autonomously grasped and pulled to a pair of notched dissection blades to remove the head of the mosquito, allowing access to the salivary glands. Placement into these blades is adapted based on output from computer vision to accommodate for the unique anatomy and orientation of each grasped mosquito. In this pilot test of the system on 50 mosquitoes, we demonstrate a 100% grasping accuracy and a 90% accuracy in placing the mosquito with its neck within the blade notches such that the head can be removed. This is a promising result for this difficult and nonstandard pick-and-place task. Note to Practitioners-Automated processes could help increase malaria vaccine production to a global scale. Currently, production requires technicians to manually dissect mosquitoes, a process that is slow and tedious and requires a lengthy training regimen. This article presents an improved manual fixture and procedure that reduces technician training time. Furthermore, an approach to automate this dissection process is proposed and the critical step of robotic manipulation of the mosquito with the aid of computer vision is demonstrated. Our approach may serve as a useful example of system design and integration for practitioners that seek to perform new and challenging pick-and-place tasks with small, nonuniform, and highly deformable objects.
BibTeX
@inproceedings{phalen2021mosquito,
  author = {Henry Phalen and Prasad Vagdargi and Mariah L. Schrum and Sumana Chakravarty and Amanda Canezin and Michael Pozin and Suat Coemert and Iulian Iordachita and Stephen L. Hoffman and Gregory S. Chirikjian and Russell H. Taylor},
  title = {{A Mosquito Pick-and-Place System for PfSPZ-Based Malaria Vaccine Production}},
  booktitle = {IEEE Trans Autom. Sci. Eng},
  year = {2021},
  url = {https://openreview.net/forum?id=S9DQ7iN512},
}

Loading related content...

Figure