Abstract
Cellular operators are increasingly turning toward renewable energy (RE) as an alternative to using traditional electricity in order to reduce operational expenditure and carbon footprint. Due to the randomness in both RE generation and mobile traffic at each base station (BS), a surplus or shortfall of energy may occur at any given time. To increase energy self-reliance and minimize the network’s energy cost, the operator needs to efficiently exploit the RE generated across all BSs. In this paper, a hybrid energy sharing framework for cellular network is proposed, where a combination of physical power lines and energy trading with other BSs using smart grid is used. Algorithms for physical power lines deployment between BSs, based on average and complete statistics of the net RE available, are developed. Afterward, an energy management framework is formulated to optimally determine the quantities of electricity and RE to be procured and exchanged among BSs, respectively, while considering battery capacities and real-time energy pricing. Three cases are investigated, where RE generation is unknown, perfectly known, and partially known ahead of time. Results investigate the time varying energy management of BSs and demonstrate considerable reduction in average energy cost thanks to the hybrid energy sharing scheme.
Introduction
As global mobile data traffic continues its exponential growth, the energy consumption of cellular networks has become a critical concern for operators. High operational expenditures (OPEX) and a mounting carbon footprint have pushed the industry toward integrating renewable energy (RE) sources like solar and wind at base station (BS) sites. However, the inherent volatility of RE—where one tower may experience a surplus while a neighboring tower faces a deficit due to localized weather or traffic spikes—presents a significant management challenge.
To address this, researchers have proposed energy sharing. Traditionally, this happens via the Smart Grid (Virtual Sharing), where excess energy is sold to the grid and repurchased elsewhere, or via Physical Power Lines, which connect towers directly. While the grid acts as a costly middleman, physical lines involve high upfront installation costs. This paper proposes a "hybrid" framework that strategically combines both methods to maximize efficiency and minimize costs.
A Hybrid Sharing Architecture
The core of the proposed system is an Energy Management Unit (EMU) that coordinates energy flows between RE sources, local storage batteries, the smart grid, and neighboring base stations.
In this model, the EMU decides in real-time whether to store harvested energy, use it to power the BS, sell it to the smart grid, or transmit it directly to a physically connected neighbor. The primary economic driver for physical connections is the "Smart Grid Tax"—the price spread between buying and selling electricity on the open market. By sharing energy directly, operators can bypass these transaction costs and resistive losses associated with long-distance grid transport.
Strategic Planning: The Clustering Phase
Because connecting every tower with physical cables is cost-prohibitive, the framework employs a two-phase approach. The first phase involves Clustering, where algorithms determine which BSs should be physically linked. The researchers developed two primary metrics for this:
- Average Energy Affinity (AEA): A metric based on complementary average energy profiles.
- Stochastic Energy Affinity (SEA): A more sophisticated metric that considers the full probability distribution of energy generation and demand, identifying pairs that statistically balance each other's surpluses and deficits over time.
As shown in the network topology, physical connections (solid lines) are prioritized for nearby, highly compatible clusters, while virtual connections (dashed lines) handle sharing across larger distances or between less compatible nodes.
Real-time Operation and Optimization
Once the physical infrastructure is set, the system enters the Operational Phase. The EMU solves a convex optimization problem to manage hourly energy flows. The study tested this under three scenarios of foresight:
- Zero Knowledge: Decisions are made based only on current state.
- Perfect Knowledge: An idealized benchmark where future RE generation is known.
- Partial Knowledge: A realistic model using weather statistics to inform "risk-aware" battery and sharing strategies.
Key Results and Insights
The hybrid framework demonstrates significant advantages over traditional single-method approaches:
- Cost Efficiency: The system achieved an approximate 37% reduction in average energy costs compared to networks with no sharing capabilities.
- Metric Superiority: The SEA metric consistently outperformed AEA. By accounting for the statistical nuances of energy generation rather than just averages, the SEA-based clustering led to more effective cabling choices and lower grid dependence.
- Grid Independence: As the physical sharing range increases, the reliance on the smart grid drops sharply, protecting the operator from fluctuating energy prices.
Conclusion and Future Work
The proposed hybrid framework offers a pragmatic path toward sustainable cellular infrastructure. By combining the low-latency, low-cost benefits of physical lines with the flexibility of the smart grid, operators can significantly reduce their OPEX. Future research may expand these models to include non-linear battery degradation and multi-operator cooperative sharing environments, further refining the economic viability of green 5G and 6G networks.
Summary updated