Abstract
Computed tomography (CT) is one of the most common medical imaging modalities and the main technology used in radiomics research, the computational voxel-level analysis of medical images. Analysis of CT images is vulnerable to the effects of dental artifacts (DA) caused by metal implants or fillings. Running automated analysis pipelines with uncurated datasets can reduce performance and hamper future reproducibility on new datasets. This work introduces a new tool to detect the location and magnitude of DAs in CT images based on a combination of deep learning and conventional image processing algorithms. We show the utility of this new DA detector through an analysis of the correlations between radiomic features and the location of DAs in 2,319 CT axial volumes. We were able to predict the correct DA magnitude (no, weak or strong artifacts) yielding a Matthews correlation coefficient of 0.73 (p-value=0.0002), achieving the same level of agreement as human labellers. The algorithm was able to identify the location of the DAs in the CT volumes with performance on par with human labellers. Finally, our analysis of radiomic features showed that only when strong DAs were present, the proximity of the tumour to the mouth was highly correlated with specific radiomic features. Our results suggest that removing these features, or removing CT slices containing the DAs, could reduce these unwanted correlations.
Introduction
In the field of radiomics, researchers extract thousands of quantitative features from medical images to build predictive models for personalized medicine. However, the reliability of these models depends heavily on data quality. A significant source of noise in head and neck CT scans is the dental artifact (DA). Metal fillings or implants cause extreme X-ray attenuation, resulting in high-intensity streaks that obscure anatomy and distort mathematical features.
Historically, researchers have either ignored these artifacts, introducing noise into their models, or discarded entire patient datasets containing any metal, leading to substantial data loss. This study presents DAART (Detection of Artifacts for Automated Radiomics Technologies), an automated hybrid tool designed to detect, locate, and quantify the magnitude of these artifacts, allowing for more precise data curation.
Methodology
The DAART system utilizes a two-step hybrid architecture to classify scans into three categories: Strong, Weak, or None.
Sinogram-Based Detection (SBD)
The first component is a classical image processing approach using the Radon transform. It analyzes the "sinogram" space of the image to identify high-intensity streaks extending into the air surrounding the patient, which are characteristic of metal artifacts. This is followed by a histogram peak detection algorithm to locate the artifact along the z-axis.
Convolutional Neural Network (CNN)
A 5-layer CNN acts as a secondary classifier to verify the presence of artifacts within the 3D volume. The hybrid logic combines these outputs: for instance, if both SBD and CNN flag an artifact, it is labeled "Strong," whereas if only the CNN flags it, it is labeled "Weak."
Data and Validation
The study utilized the RADCURE dataset, comprising 3,211 head and neck cancer CT volumes. To establish a ground truth, the team developed ALTAR (Artifact Labelling Tool for Artifact Reduction), an open-source web application used by researchers to manually annotate artifact magnitude and location across thousands of slices. A subset of 2,319 volumes was used for final testing.
Results
The hybrid algorithm demonstrated human-level performance, achieving a Matthews Correlation Coefficient (MCC) of 0.73 for three-class classification—matching the level of agreement between two human experts. Furthermore, the tool identified the "strongest" artifact slice to within 5 slices of human labels in 92% of cases.
A key finding was the "Distance Matters" discovery: 36 specific radiomic features were highly correlated with the artifact only when the tumor (GTV) was in close proximity to the mouth. Interestingly, 34 of these 36 corrupted features belonged to the "lbp-3D-kurtosis" filter family, suggesting specific mathematical textures are uniquely vulnerable to metal streaks.
Discussion and Conclusion
DAART enables "surgical" data cleaning. Rather than discarding entire patient records, researchers can remove only the specific CT slices containing the DA or exclude the specific vulnerable features from their models. This approach significantly reduced the number of corrupted features in the test set (from 442 down to 123) while preserving the majority of the dataset.
While the current iteration focuses on vertical (z-axis) distance, future work may explore horizontal (x, y) plane effects. Integrating this tool into automated clinical pipelines could provide real-time flagging of questionable radiomic results, enhancing the reproducibility and reliability of personalized medicine models. The authors have made the ALTAR tool and the DAART algorithm open-source.
Summary updated