Abstract
The quality of images captured by wireless capsule endoscopy (WCE) is key for doctors to diagnose diseases of the gastrointestinal (GI) tract. However, there exist many low-quality endoscopic images due to the limited illumination and complex environment in the GI tract. After an enhancement process, severe noise becomes an unacceptable problem. The noise varies with different cameras, GI tract environments, and image enhancement, making the noise model hard to obtain. This paper proposes a convolutional blind denoising network for endoscopic images. We apply the Deep Image Prior (DIP) method to reconstruct a clean image iteratively using a noisy image without a specific noise model or ground truth. Then, we design a blind image quality assessment network based on MobileNet to estimate the quality of the reconstructed images. The estimated quality is used to stop the iterative operation in the DIP process. The number of iterations is reduced by about 36% by using transfer learning in our DIP process. Experimental results on endoscopic images and real-world noisy images demonstrate the superiority of our proposed method over state-of-the-art methods in terms of visual quality and quantitative metrics.
Introduction
Wireless Capsule Endoscopy (WCE) represents a significant advancement in non-invasive gastrointestinal diagnostics. However, the device operates under challenging conditions, including low illumination and a complex, constantly moving environment. To assist clinical diagnosis, captured images often undergo digital enhancement, which inadvertently amplifies sensor noise to unacceptable levels.
Traditional denoising techniques typically rely on known noise models (e.g., Gaussian noise) or supervised learning using pairs of "clean" and "noisy" images. In the context of the GI tract, obtaining a noise-free ground truth is practically impossible due to the capsule's continuous motion. Furthermore, noise characteristics vary significantly across different hardware and enhancement algorithms. This research addresses the challenge of blind denoising—removing noise without a pre-defined model or reference images.
Proposed Methodology
The core of the proposed system is a dual-network architecture that combines iterative reconstruction with automated quality monitoring.
Deep Image Prior (DIP) and Transfer Learning
The method leverages Deep Image Prior (DIP), which utilizes the inherent structural bias of convolutional neural networks to reconstruct images. Unlike standard deep learning, DIP does not require a training dataset; it treats the network's architecture as a "prior" that naturally favors structured signals over random noise. To address the high computational cost of DIP, the authors employ transfer learning. By initializing the network with weights from a model pre-trained on typical noisy images rather than random noise, the convergence speed is significantly improved.
Blind Image Quality Assessment Network (BIQAN)
A critical challenge in DIP is the "stopping problem": if the iterative process continues too long, the network begins to reconstruct the noise itself. To solve this, the authors developed BIQAN, a MobileNet-based sub-network that predicts image quality during reconstruction.
BIQAN outputs a distribution of quality scores. By applying a low-pass filter to these scores to eliminate fluctuations caused by random input noise, the system can reliably identify the "global peak" of image quality and terminate the DIP process automatically.
Experimental Results
The performance of the proposed method was evaluated using real-world noisy images (Nam dataset) and enhanced WCE images.
Quantitative Performance
On the Nam dataset, the proposed method achieved the highest Peak Signal-to-Noise Ratio (PSNR) in 14 out of 15 test cases. It outperformed established methods such as CBM3D and Noise Clinic by an average of 0.68 dB. Furthermore, the transfer learning approach reduced the required iterations by approximately 36%, enhancing the method's efficiency.
Qualitative Analysis
Visual inspections of endoscopic images reveal that the proposed method effectively removes artifacts and noise in dark regions while preserving fine anatomical structures essential for medical diagnosis.
As shown in the comparison, while other methods like Neat Image (NI) or Noise Clinic (NC) may blur details or fail to remove specific artifacts, the proposed "Pro" method maintains a balance between smoothness and detail retention.
Conclusion and Future Work
By integrating DIP with an automated quality assessment "referee," this research provides a robust solution for blind denoising in medical imaging. While the 36% reduction in iterations is a significant improvement, the computational demand of DIP remains a hurdle for real-time clinical applications. Future research will focus on further optimizing the architecture to reduce processing times from minutes to seconds, potentially through meta-learning or hardware acceleration.
Summary updated