3D Convolutional Sequence to Sequence Model for Vertebral Compression Fractures Identification in CT

David Chettrit, Tomer Meir, Hila Lebel, Mila Orlovsky, Ronen Gordon, Ayelet Akselrod-Ballin, Amir Bar

Abstract

Vertebral Compression Fractures (VCFs) are significant indicators of osteoporosis but are frequently overlooked in routine clinical CT scans. This paper introduces an automated end-to-end system for VCF identification using a novel 3D convolutional sequence-to-sequence (Seq2Seq) architecture. By treating the vertebral column as a sequence of 3D volumetric patches and leveraging Bi-directional Long Short-Term Memory (BiLSTM) networks, the model captures essential 3D spatial details and anatomical context. Evaluated on a large-scale clinical dataset of 2,489 CT series, the system achieved a state-of-the-art Area Under the Curve (AUC) of 0.955, demonstrating its potential for real-time clinical screening.

Introduction

Osteoporosis-related fractures represent a major global health challenge, with a fracture occurring every three seconds. VCFs are particularly critical as "warning signs"; over 55% of major osteoporotic fractures are preceded by these often asymptomatic events. Despite their importance, VCFs are missed in 13-16% of routine radiological reports because they are frequently incidental to the primary diagnostic objective.

Previous automated detection efforts have been limited by 2D representations or small datasets that fail to capture the full 3D complexity and sequential nature of the spine. This work addresses these gaps by proposing a robust 3D Seq2Seq pipeline validated on a diverse clinical population.

Methodology

The proposed system follows a multi-stage pipeline to transform raw CT data into a fracture diagnosis:

  1. Localization: A YOLO-based CNN identifies the spinal cord on axial slices to define a Region of Interest (ROI).
  2. 3D Representation: Sagittal views are reconstructed, and a sequence of 3D volumetric patches is extracted along the vertebral column.
  3. Feature Extraction ($F_{rep}$): Each 3D patch is processed through a 3D CNN. A scalar location descriptor is appended to these features to provide global anatomical context (e.g., distinguishing thoracic from lumbar vertebrae).
  4. Sequence-to-Sequence Classification ($F_{seq}$): The feature sequence is fed into a BiLSTM network, allowing the model to evaluate each vertebra in the context of its neighbors.
  5. Aggregation ($F_{agg}$): A max function aggregates the sequence of probabilities into a final patient-level score.
Overview of the automated VCF identification pipeline, from spinal cord detection to sequence classification.

A key innovation is the use of 3D volumetric patches instead of 2D slices. This preserves vital intensity and texture details necessary for identifying subtle bone structural changes. Furthermore, the Seq2Seq approach treats the spine as a biological "sentence," where the context of adjacent vertebrae helps distinguish true fractures from normal anatomical variations.

Experimental Results

The model was trained and tested on one of the largest datasets in the field, comprising 2,489 standard CT series from multiple institutions and scanner types. The ground truth was established by a consensus of three board-certified radiologists.

The final system achieved a patient-level AUC of 0.955, with a sensitivity of 0.822 and a specificity of 0.951. Notably, the pipeline is highly efficient, processing a case in approximately 61 seconds on a standard 16-core CPU.

ROC curves illustrating the performance impact of different model components, including the BiLSTM and location descriptors.

As shown in the ROC analysis, the inclusion of location descriptors ("max prob + loc") provided a measurable performance boost over the baseline models. While the system is highly effective, challenges remain in identifying "mild" fractures (20-25% height loss) and distinguishing VCFs from mimics like Schmorl nodes, which are difficult even for human experts.

Conclusion

This work demonstrates that a 3D Seq2Seq architecture can effectively automate VCF detection in routine CT scans with high reliability. By combining local 3D features with global sequential context, the model achieves state-of-the-art performance on a large, representative clinical dataset, offering a viable tool for improving the diagnosis of osteoporosis-related fractures in clinical practice.

Summary updated

BibTeX
@inproceedings{chettrit2020d,
  author = {David Chettrit and Tomer Meir and Hila Lebel and Mila Orlovsky and Ronen Gordon and Ayelet Akselrod-Ballin and Amir Bar},
  title = {{3D Convolutional Sequence to Sequence Model for Vertebral Compression Fractures Identification in CT}},
  booktitle = {International Conference on Medical Image Computing and Computer-Assisted Intervention},
  year = {2020},
  doi = {10.1007/978-3-030-59725-2\_72},
}
Figure