Abstract
A systematic analysis of pupil size variations is a rich source of information about a subject's arousal and cognitive state. Current methods are limited to descriptive statistics and struggle with inter-subject variability. We present a data-driven approach using 1-D Convolutional Neural Networks (CNNs) applied directly to raw pupil size data. We test this method on a binary classification task between Parkinson's disease patients (PDs) and healthy controls (HCs). 1-D CNN models trained on short-range sequences (10-60 seconds) provide high average accuracy, outperforming traditional baselines.
Introduction
The human pupil fluctuations reflect autonomic nervous system activity, offering a window into neurological health. However, analyzing these pupillary oscillations is challenging due to high inter-subject variability, the need for heavy pre-processing (like blink removal and noise filtering), and non-stationarity in biological signals. Traditional methods relying on Fourier or Wavelet transforms often fail to capture the complex dynamics necessary for accurate diagnosis. This research proposes an end-to-end deep learning approach to automatically extract diagnostic features from raw, noisy pupil data.
Methods
The researchers employed 1-D Convolutional Neural Networks (1D-CNNs), which are specifically designed to identify local patterns in time-series data. Unlike traditional feature engineering, this model uses convolutional layers as learnable filters to enhance biological signals and suppress noise.
A critical component of the architecture is the integration of a Batch Normalization (BN) layer, which allows the network to learn optimal data scaling rather than relying on fixed mathematical rules. To prevent overfitting on the relatively small dataset, Dropout was applied directly to the input.
The final 1D-CNN architecture includes two convolutional layers with pooling, a flattening layer, and a fully connected layer leading to a softmax output for binary classification (PD vs. HC).
Experimental Setup
The study used monocular pupil size recordings from 36 participants (21 Healthy Controls and 15 Parkinson’s patients) captured in scotopic conditions (total darkness). Recordings were sampled at 240 Hz and segmented into sub-sequences of 10, 15, 30, and 60 seconds. Missing data from blinks were handled using cubic spline interpolation.
Key Results
The 1D-CNN model significantly outperformed standard Multi-Layer Perceptrons (MLPs) and traditional statistical baselines.
As shown in the results table, the model achieved its highest accuracy of 81.26% (±1.79) using 15-second sequences with Batch Normalization. This "Goldilocks" length suggests that 10 seconds may be too short to capture dynamics, while 60 seconds may introduce too much noise. Notably, the learnable Batch Normalization (BN) approach vastly outperformed traditional pre-processing (PP) normalization, improving accuracy by over 20% in some cases.
Conclusion
This study demonstrates that 1D-CNNs can effectively diagnose Parkinson's Disease from raw pupil size variations. By bypassing manual feature engineering and utilizing learnable normalization, the model achieves high accuracy on short data sequences. Future work will focus on expanding the dataset to improve generalizability and exploring temporal models like LSTMs or Transformers to capture longer-term dependencies in pupillary behavior.
Summary updated