Journal of Magnetic Resonance 2017

5 papers
In 2017, the Journal of Magnetic Resonance featured research primarily focused on hardware engineering and instrumentation for high-field magnetic resonance imaging (MRI) and spectroscopy. A significant portion of the work involved the development of specialized radiofrequency coils. For instance, researchers such as Chang‐Hoon Choi and N. Jon Shah detailed the design of a folded four-ring double-tuned birdcage coil for sodium imaging in rat brains at 9.4 T. Another study introduced a 1H/19F double-tuned coil system utilizing PIN-diode switches, also optimized for 9.4 T applications. Beyond coil design, the year’s contributions included advancements in experimental apparatus for real-time and wideband applications. Notable developments included an optimized fast mixing device for real-time NMR studies and a cryostatic, wideband nuclear quadruple resonance (NQR) spectrometer designed for the VHF range. These technical improvements reflect a trend toward enhancing sensitivity and multi-nuclear capabilities in high-field environments. Prolific contributors during this period included Yonghyun Ha, Adrien Favier, and Bernhard Brutscher, whose work supported the refinement of magnetic resonance methodologies through improved hardware and scanning techniques.

Top Research Directions

The 1 research directions with Journal of Magnetic Resonance 2017 papers, ranked by paper count. Share is the fraction of the edition’s papers in the direction.

#DirectionPapersShare
1Cryogenic Front-End Electronics for High-Sensitivity Signal Processing120.0%

Download all directions as CSV

Institutions

Institutions credited by Journal of Magnetic Resonance 2017 papers: a paper credits every institution named in its affiliations, once. 1 institutions share 1 credited papers.

#InstitutionPapersShare20162016 rank
1Graz University of Technology 1100.0%0—

Download all institutions as CSV

About this data

Papers. Journal of Magnetic Resonance 2017 lists 5 papers on Lacuna, duplicate versions counted once; rejected and withdrawn submissions are left out.

Directions. Directions are Lacuna’s clustering of the concept elements extracted from each paper, so a paper can belong to several and direction counts add up to more than the paper count. A direction’s share is its papers divided by the edition’s papers.

Institutions. A paper credits each institution named in its affiliations, resolved to a ROR record, once. 1 of 5 papers (20.0%) credit at least one institution and are the base for institution shares; the rest have no resolved affiliation yet.

Data. Counts come from Lacuna’s data build of 2026-11-20 and change as papers are added. Tables as CSV: directions · institutions. Cite as: Lacuna, “Journal of Magnetic Resonance 2017”, https://lacuna.tiptreesystems.com/venue/journal-of-magnetic-resonance/2017.

Top Authors

AuthorPapers
N. Jon Shah2

Papers

Title
A cryostatic, fast scanning, wideband NQR spectrometer for the VHF range
Design and construction of a novel 1 H/ 19 F double-tuned coil system using PIN-diode switches at 9.4 T
Design and use of a folded four-ring double-tuned birdcage coil for rat brain sodium imaging at 9.4 T
Design and use of a folded four-ring double-tuned birdcage coil for rat brain sodium imaging at 9.4 T
Optimized fast mixing device for real-time NMR applications