Techniques for Cable Force Measurement During Construction of Cable-Stayed Bridge

Fentao Guo, Yufeng Xu, Sixin Fu, Zhantao Zhang, Qilong WangAdvances 2025 · DOI · OpenAlex

Abstract

The schemes for cable force measurement during construction of the Longwan Bridge are described and the principle of the cable force measurement with frequency method is introduced. With the measurements of cable forces of the Longwan Bridge being taken as the research background, the relations between cable forces and frequencies are obtained by the combination of finite element method and spline fitting. In the end, part of the results of the measurement is presented.

Introduction

In the construction of cable-stayed bridges, the tension within the stay cables is a primary determinant of the structure's overall integrity and geometric alignment. Ensuring these forces match design specifications is critical for safety. Traditional measurement techniques, such as using load cells or monitoring hydraulic jack pressure, often prove expensive or difficult to implement across the numerous cables of a large-scale project.

The "frequency method" offers a non-destructive, efficient alternative by calculating tension based on a cable's natural vibration frequency. However, the relationship between frequency and force is non-linear and influenced by complex factors like cable sag and bending stiffness. This paper details the application of an advanced frequency-based measurement system during the construction of the Longwan Bridge.

Methodology: The Frequency-Force Relationship

The core challenge of the frequency method lies in accurately modeling the mathematical relationship between a cable's vibration and its internal tension. The authors address this through a multi-stage analytical process:

  1. Finite Element Modeling (FEM): Rather than relying on simplified analytical equations, the team used FEM to simulate cable behavior. They accounted for specific boundary conditions (clamped ends) and refined the model by adjusting bending stiffness to 0.37 times the sectional flexural stiffness.
  2. Spline Fitting: FEM simulations provided discrete data points relating various tension levels to natural frequencies. To create a continuous, practical formula for field use, the authors applied spline fitting techniques to these data points.
  3. Data Acquisition Workflow: The system utilizes wireless sensor nodes to capture vibrations, which are then processed to extract frequency data and subsequently converted into force measurements using the fitted model.
Workflow of the cable force measurement system using the frequency method

Field Implementation and Signal Processing

For the Longwan Bridge project, which features 100 pairs of stay cables, the team deployed self-developed wireless vibration acquisition modules. These high-sensitivity acceleration sensors are capable of detecting ambient environmental vibrations, eliminating the need for manual excitation of the cables.

Wireless vibration sensor node installed on a stay cable of the Longwan Bridge

The captured signals underwent Fast Fourier Transform (FFT) processing with specific windowing to isolate natural frequencies. A key insight from this study is that modern sensor technology has reached a level of precision (up to 0.0001 Hz) where the overall system accuracy is no longer limited by hardware, but rather by the fidelity of the frequency-force model.

Results and Discussion

The field deployment successfully provided real-time cable force data across the bridge's spans. When compared to the original design values for a subset of cables (Cables 1-10 on Bridge No. 22), the measured forces showed deviations ranging from -3% to +17%.

While the forces were generally well-distributed and aligned with the design intent, the observed discrepancies highlight areas for further refinement. These deviations may stem from construction tolerances, environmental factors like temperature, or the need for even more precise boundary condition assumptions in the FEM model. Overall, the combination of FEM modeling, spline fitting, and wireless sensing proved to be a practical and reliable approach for monitoring cable-stayed bridge construction.

Summary updated

Abstract

The schemes for cable force measurement during construction of the Longwan Bridge are described and the principle of the cable force measurement with frequency method is introduced.With the measurements of cable forces of the Longwan Bridge being taken as the research background, the relations between cable forces and frequencies are obtained by the combination of finite element method and spline fitting.In the end, part of the results of the measurement is presented.
BibTeX
@inproceedings{guo2025techniques,
  author = {Fentao Guo and Yufeng Xu and Sixin Fu and Zhantao Zhang and Qilong Wang},
  title = {{Techniques for Cable Force Measurement During Construction of Cable-Stayed Bridge}},
  booktitle = {Advances},
  year = {2025},
  doi = {10.2991/978-94-6463-728-1\_38},
}
Figure